105. Chapter 7 7-10 their ladder programs using the keyboard . The keyboard actions are described below: Left/Right/Up/Down cursor keys The cursor keys are for moving the high light bar from one element to another in their four respective directions. You can only move in a dire ction which will end up with an element. <ESC> Press <ESC> key to end the circuit editing mode and return to the browse mode of the logic editor. <Enter> When you are done with editing the current circuit, hit <Enter> to proceed to the next circuit. <SHIFT> (or <TAB>) If you observe the highlight bar carefu lly, you will notice a dark green color square at the right end of the highlight. This indicates the insertion location where a series contact will be attached. You can change the insertion location to the left or the right of the highlight bar by pressing the <SHIFT> key. (Note: prior to Version 5.32 only the <TAB> key wa s used for this purpose, but <TAB> key does not work on JRE 1.4.x so we added the <SHIFT> key to achieve this action). The position of the insertion point ha s no effect when you connect a parallel contact to the highlighted element. The le ft terminal of the element will always be connected to the left side of the parallel branch. <0> to <9> , </> & <E> keys Pressing the key <0> to <9> and </> is eq uivalent to clicking on the icon shown in the table. The equivalent keyboard nu mber is shown as a small numeral at the lower right corner of the icon. The </> ke y is the quickest way of converting a normally-open contact to a normally-closed one (and vice versa). Pressing the <E> key when a co ntact or coil is selected allows you to edit the label name directly. Note that it is the us er's responsibility to ensure that the label is valid.

46. Chapter 4: Using TLServer 4-3 known as "client" programs). So whether your PC is networked or not, you can still use TLServer and i-TRiLOGI on a localhost connection. In that case the i-TRiLOGI and TLServer work together on the same PC just like a normal Window based programming software. We recommend using the localhost IP address: 127.0.0.1:9080 if you are running both the client and the server on the same PC. 2. If the computer has an 'always on' co nnection to the Internet directly then the IP address will be your Internet IP address. 3. If the computer is networked to the corporate Intranet, or you have connected this computer to a router to share internet connection with a few other computers, then the IP addre ss shown is an internal IP address, also known as the "Intranet" IP address. The intranet IP a ddress is assigned by either the System Adminstrator or the router (known as DHCP server). You can access this computer from ot her computers in the same LAN, but the intranet IP address is not accessible from outside of the LAN. To access the TLServer from outside of the LA N, You will need to configure your router's internal settings to define the PC that runs the TLServer as a "Virtual Server". You can then access t he TLServer using the router's public IP address and the router will does the job of translating the public IP address to the intranet IP address and route the messages to/from the PC that has been defined as the virtual server. This process is known as Network Address Translation (NAT). 4. Dial-Up Users: If you ar e testing the internet capa bility of TLServer using dial-up connection, you must connect to the Internet first before starting TLServer so that TLServer can report the correct Internet IP address to you. You will not see the local host IP address (127.0.0.1), only the Internet IP address will be shown. The moment TLServer is running, it is ready to accept connection from the i- TRiLOGI client. You can also configure TL Server's communication port setting, add/remove users from the system and set up TLServer to query the PLC for outgoing email requests an d process them accordingly. For explanation of the function of each button, click the image link of respective buttons below. You can also call up their context-sensitive hel p by pressing <F1> key after pressing the relevant button on the TLServer front panel. NOTE: TLServer version 3.17 has a new an d improved Email Setup area. To view the changes, click on the "Setup Emails" button below as described above.

16. Chapter 1 I-TRiLOGI Setup Guide 1-3 4. Next you will see the first step in the installation process that recommends closing open programs. Click ‘Next’ to continue. 5. The next step is to accept the licens e agreement. Click ‘Yes’ to accept it and continue.

19. Chapter 1 I-TRiLOGI Setup Guide 1-6 10. Now the installation setup is complete and you just need to click ‘Install’ to start the installation process. 11. Installation is taking place. Wait for the Setup to complete automatically.

20. Chapter 1 I-TRiLOGI Setup Guide 1-7 12. Installation is nearly complete. An information box will appear and after reading it, click ‘Next’ to continue. 13. Finally, installation is complete. Cl ick ‘Finish’ to close the window and proceed to the next section of this manu al for instructions on running TRiLOGI and TLServer.

124. Chapter 8 8-18 firmware r47 and above). Note that the data memory type may not actually be EEPROM (could be Ferro-Magnetic RAM (FRAM) or FLASH), but the EEPROM manager will work the same way. The EEP ROM manager also allows you to save or load the data to and from the PC’s hard disk. When the “EEPROM Manager” is selected, you will see the following screen: There are two buffer areas: The left dark bl ue text area is a buffer to hold 16-bit Integer EEPROM data, the right text area is to hold the String EEPROM data. You can manually enter data in the buffer area s that are to be written to the data EEPROM, or if you retrieve data EEPROM (i nteger or string) from the PLC the data

137. Chapter 8 8-31 If an F-series PLC is to be accessible only on the local area network, then the direct connections offered by MODBUS/T CP provide simplicity without time- consuming login sequences. Ho wever, if the MODBUS/TCP port is to be exposed to the public Internet, then you ought to consider the security issues associated with MODBUS/TCP connections. Since a MODBUS/TCP connection does not require a username/password login sequenc e (unlike the FServer login), the only way to protect against unauthorized access is through the “Trusted IP” addresses defined using the F-Series Ethernet Configuration software. The first thing you should do is to click on the “Retrieve Parameters from F-PLC” so that you can capture a copy of the current configuration in the PLC and you can then modify selectively. You can define a list of up to 6 “Trusted IP” addresses in this panel. To enable the Mo dbus/TCP Trusted IP, click on the “Yes” button next to the “Modbus/TCP Use Truste d IP”. Note: The FServer can also be enabled to only allow connections from devices that match one of the “Trusted IP” defined in this panel. This is on to p of the username/password login sequence that can be enabled/disabled from the Basic Configuration screen. In other words, you can choose either security method to access the FServer or implement both security methods at the same time. After you have defined the list of trus ted IP addresses and checked the “Use Trusted IP” radio button, cli ck on the “Save Parameters to FServer” to save your data to the PLC’s nonvolatile memory. When “MODBUS/TCP Use Trusted IP” is enabled, it means that only TCP/IP packets that come from a client whose IP address matches one of the “Trusted IP” would be allowed connection to the MODBUS/TCP server. 3. Calibration of ADC and DAC & Moving Average Definition The ADC and DAC are factory-calibrated such that a voltage of half of fullscale voltage (5.00V on F2424, an d 10.00V on F1616-BA) should return a value of 2048 when read by the ADC(n) function. Like wise, an output voltage of half of fullscale voltage should be present at the DAC pin when you SETDAC to 2048. However, if there is a need to re-calibrate the ADC and DAC, you can follow the procedure outlined below. To perform calibration of an ADC ch annel, you need to supply a precise DC reference voltage to the ADC channel, and then check the analog readings obtained via the ADC(n) function and co mpare it to the expected value. If there is an error, you can apply a correction factor to it.

243. Chapter 12 12-27 32-bit integers and the function returns a 32-bit integer that can be assigned to any variable. Any scaling for actual output (DAC or PWM) will be co mputed by the user within the same CusFn and sent to the output. Example : E = 10000 - ADC(2)*20 A = PIDcompute(5,E) setPWM 4, (A + 8000)/100 Comments: The set point value is 10000 units, the feedback value is read from ADC channel #2 and then multiplied by 20 to convert (scale) it to the same unit as the parameter to be controlled. PID computation channel #5 (assume somewhere in the program a PIDdef for channel #5 has been executed before) is then used to compute the desired controller output value using the error signal (= set point - feedback value ADC(2) x 20). The desired output (stored in variable A) is then added to the offset value 8000 and then scaled down by a factor of 100 before being sent out physically via PWM Channel #4. Important : In actual implementation, use a clock pulse such as 0.1s, 0.5s or 1s etc to periodically activate the PIDcompute( ) function so that digital control in di screte-time can be implemented. The PID sampling period depends on the time constant of the system. For very slow response processes such as the cooking temperature of a large body of water, the time constant is very large and even slower than 1.0 seconds clock may be sufficient. Do not use unnecessarily short sampling time because it increases comput ation time and slows down overall performance of the system.

13. Chapter 1 I-TRiLOGI Setup Guide Chapter 1 Set Up i-TRiLOGI

18. Chapter 1 I-TRiLOGI Setup Guide 1-5 7. The next step is to select the installa tion folder. It is recommended to use the default option, which is “C:\TRiLOGI” 8. If this installation is an upgrade, then the installation folder may already exist and you will get prompted to use the same folder or choose a new one. If you don’t see this, skip to the next step . Otherwise, click ‘Yes’ to use the same installation folder. 9. Now you will be asked to choose a na me for the start menu group, which is what you will see in the PCs start menu pr ogram listing. Click ‘Next’ to use the default option.

103. Chapter 7 7-8 7.4.1 Mouse Actions Left Click - When you click on an element using a the left mouse button, the element is selected and highlighted by the yellow color highlight bar. Right Click - When you click on an element using the right mouse button, you are allowed to directly edit the labe l name of the element. This can be a convenient feature if you need to chan ge one or two characters in the name only. However, if the element is a custom function [dCusFn], or [CusFn], then the custom function editor will be opened for you to edit the function directly. Insert Ladder Element - You create the ladder circuit element simply by moving the mouse pointer to the icon and pressi ng either the left or the right mouse button to insert a ladder logic element to the currently highlighted element. The following is a description of the function s of each icon. A yellow color highlight bar will appear which you can move to select an element in the ladder circuit.

28. Chapter 3 Chapter 3: Interfacing to the PLC

113. Chapter 8 8-7 To print, first select the item from the choice box and define the range you wish to print and then click on the "Print" bu tton. For "Ladder Circuits", the range indicates the circuit numbers. For "I/O Tables", the range indicates the I/O number (up to 256) and for "Custom Fu nctions", the range is the function number. You can use the "Print preview" button to check the pagination of the printing on screen. You can select paper size and print orientation. etc. by clicking the "Page setup" button. Empty custom func tions will be automatically skipped to save paper. When you select to print the "Ladder Circuits" a special "No. of Element" textbox appears. This textbox is for you to enter the maximum number of series element that can be printed on the paper width. Changing this number affects the scaling of the ladder diagram when printed. The smallest number is 5 and largest number is 13. Use a smaller number if you wish to have a larger printout. However, please note that if yo ur ladder program contains circuits with more elements than that indicated by the "No. of Element" parameter, the "out- of-page" part of those ladder circuits will not be printed. Wider I/O Table Previously, the I/O Table label names could only be 10 characters, but i-Trilogi 6.2 and up allows label names of up to 16 characters (see the IOTable section for more details). It is now possible to print an I/O Table with label names up to 16 characters and still fit all of the inform ation within the page width. The only difference is that Relays #257 to 512 will be printed on a second page to provide more room. Export the I/O Table Now you can export the I/O Table to a ".csv" file that can be opened by any program that has ".csv" comp atibility. If you use Microsoft Excel, you can open

127. Chapter 8 8-21 a) Using EEPROM Manager, it is now po ssible to pre-load the PLC’s data EEPROM (either as 16-bit integer or A SCII strings) with pre-defined content so that they can be used by the PLC program. This is very convenient for implementing a lookup table or to define a large number of ASCII text string constants to be used for LC D display or commu nication without taking up too much program memory. b) If you use the PLC’s data EEPROM for data-logging, it is now possible to retrieved the saved data from the PLC and write it to the hard disk as a comma-delimited text file, which can then be imported into a spreadsheet or database program for further actions. c) If you ever need to replace a PLC that logs data to its data EEPROM area, you now can also use the EEPROM Manager to retrieve all the data EEPROM content from one PLC and transfer them to the replacement PLC so that the replacement PLC will work identically to the original PLC. 8.3.10 Ethernet & ADC Configuration This tool, which is located in the "Contr oller" Menu, allows you to configure the Ethernet Port and ADC/RTC calibration se ttings on a TRi's PLC with built-in Ethernet port, such as the F-Series PLCs. When the “Ethernet & ADC Calibration” is selected, you will see the following screen:

128. Chapter 8 8-22 Note: Default settings shown here. The configuration tool commu nicates with the PLC via the same user interface as all other communication functions un der the "Controller" menu. This means that the configuration tool will be co mmunicating with the PLC using TCP/IP protocol. Since only PLCs with built-in Et hernet can utilize this function, it means that most likely the PLC would be connected to a router or switch with a preconfigured static IP address. If your PC is also on the same network then you simply login to the PLC server using the stat ic IP address of the PLC. Of course if the PLC's Ethernet port is already mapped to a public IP address then you can also remotely configure the PLC via the Internet. However, if you do not know or have lost the IP address of the PLC, t hen it is still possible to configure the PLC's Ethernet port by connecting the serial ports on the PLC to the PC. However, in this case you will need to run the TLServer on your PC and configure the serial port to wo rk with the PLC's serial port. The

129. Chapter 8 8-23 configuration tool will connect to the PLC indirectly via the TLServer software. Click here for more details about TLServer. Before you make any changes to the PLC's Ethernet configuration parameters, it is a good idea to retrieve the current sett ings. You can do this by clicking on the “Retrieve Parameters from PLC” butto n and answer "Yes" when prompted. If your i-TRiLOGI is not yet connected to a TL Server software or directly to the PLC built-in hostlink command server (known as F-Server in the F-series PLCs), then you will see the login popup windows as follow: If you are connecting to the PLC via TLSe rver that runs on the same PC as i- TRiLOGI, then simply select the "localhost-127.0.0.1:9080" to connect to TLServer. If you are connecting to the PLC's host link command server, the IP address of the PLCs' and the port number should be entered in the "Server's IP Address:Port" field and select the corresponding radio button. The default settings for the Ethernet port are IP: 192.168.1.5 and po rt: 9080 with no username and password required (same as shown in the screens hot above). Once you have entered the correct login information, click on the "D etect ID" button and wait for the PLCs ID to populate in ID box (01 is the default ID). Then click "OK" and the configuraton tool will be populated with the current Ethernet settings. After you have retrieved the existing para meters from the PLC, you will see that various fields in the configuration softwa re screen are filled up. These fields and the remaining unpopulated fiel ds can be configured as described in the rest of this document.

143. Chapter 8 8-37 In order to calibrate the analog inputs , you need to have one or more stable and quiet reference voltage source(s) an d a precision voltmeter. First, connect the voltage source to all the PLC's analog inputs that you wish to calibrate. For best precision, select a voltage source th at falls somewhere in the middle of the range of analog values that you are concerned with. For example, if the temperature sensor that you normally measure with would return a voltage between 2.3V and 4.5V. Then it is best to calibrate using a voltage source around 3V. After connecting the voltage so urce to the analog inputs, use your precision voltmeter to meas ure the actual voltage and convert it to a reading that you expect the ADC(n) to return. E.g. if your voltage source measures 3. 045V and your analog input range is 0-5V, then the expected reading that ADC(n) should return corresponding to 3.045V should be = 3.045/5.000 x 4096 = 2494. Lets sa y If you are only calibrating analog input #1, #3 , #7 and #8 only and the rest are not used, then enter the value into the "Expected ADC(n)" fields for ea ch channel as shown below. Leave any unused channel blank. When you have finished entering the expected ADC data, then click on the button "Calibrate Analog Inputs" to start calibration. The calibration program will first clear t he old calibration da ta in the PLC and reboot it once. After that it will read 50 samples from the PLC's analog inputs and compare it against the expected AD C(n) value. The average readings of the 50 samples is then used to comput e the calibration parameters and the program will store the calibration paramete rs into the PLC and reboot it again. The analog inputs are thus completed in a single step. You may also use different voltage refe rences to calibrate different analog channels. Simply leave the channel(s) that you do not want to calibrate with the currently selected voltage source BLANK. (Note: The calibration tool will NOT calibrate any channels whose field are left blank):

233. Chapter 12 12-17 12.27 IF .. THEN .. ELSEIF .. ELSE .. ENDIF Purpose : To make a decision re garding program flow based on the result returned by an expression. Syntax : IF expression_1 [THEN] ..... [ELSEIF] expression_2 [THEN] ..... [ELSEIF] expression_N [THEN] ..... [ELSE] ..... ENDIF If the result of the expression_1 is non-zero (logical true), the block of program lines betw een the THEN and the ELSEIF statements will be executed. If the result of the expression_1 is zero (false), the block betw een the IF and ELSEIF will be ignored, and the first ELSEIF ex pression (expression_2) will be evaluated. If the result of the expression_2 is non-zero (logical true), the block of program lines between the 2nd THEN and the next ELSEIF statement will be exec uted. If the result of the expression_2 is zero (false), the block between the ELSEIF and next ELSEIF will be ignored. This pattern will repeat for all of the ELSEIF expressions until the last ELSEIF (expression_N) is re ached or one of the statements evaluates to a non-zero value (logical true). If none of the IF or ELSEIF statements evaluate to true, then the block between the ELSE and ENDIF statements will be executed instead. If there is no ELSE statement, and if the result of all the expressions is false, the block of program lines between the first THEN and the ENDIF statement will be ignored, but execution will continue right after the ENDIF statement. ELSEIF and ELIF: ELSEIF and ELIF are identical and can be used interchangeably within a IF..ENDIF statement.

321. Appendix 2 A2-15 which can vary from -limit to + limi t. We choose the 50% D/A output (4096/2 = 2048) as the mean control po int so that negative values from PIDcompute() means D/A output will be < 2048, positive values means D/A output will be > 2048.

89. Chapter 6 6-15 The purpose of this custom function is to keep a cycle count of the number of times the Sequencer has completed the complete sequencing and display the cycle count on the PLC' s built-in LCD display (or on the Simulator's "View Variable" screen). This custom functi on should be run ONLY ONCE whenever the Seq1:4 contact closes, which is wh y the differentiated version of Custom function must be used in this case ( {dCusF}, not {CusFn}) 9. We can make our program more comp rehensive to other us ers by utilizing the "Comments" feature of i-TRiLOGI. Open the "Circuit" menu and select "Insert Comment". A comment editor window will be opened up to allow you to add your comments to any part of the circuit. When you are done with your comments, just press <ESC> key or close the comment editor window and the comments you just entered wi ll be inserted between the circuits. Each comment occupies a ci rcuit position and there is no limit to the number of lines a comment circuit may have. (How ever, if you wish to keep data file compatibility with the old DOS TRiLOGI Version 4.x you should limit the comment to no more than 4 lines per comment and each line should contain no more than 70 characters.) A comment circuit may be moved around or deleted just like any other ladder circuits. If you wish to edit the comment, just double-click on it or press

151. Chapter 8 8-45 One convenient feature implemented in TRiLOGI Version 6.4 and higher is the ease of getting help for the syntax of a known TBASIC keyword. E.g., if you want to find the syntax for the keyword “READMODBUS”, instea d of navigating through the help file links, you can simp ly select the “READMODBUS” keyword in the custom function editor and you will be immediately presented with the help content for the “READMODBUS” command as illustrated in the following screen shot.

266. Chapter 12 12-50 Parameters: ch = 1, 2 or 3 (COMM port number) mode = 0 - Auto sensing (default mode) 1 - Fixed at RTU mode 2 - Fixed at EMIT mode 3 - Fixed at MODBUS ASCII mode 4 - Fixed at OMRON C20H protocol mode 5 - Fixed at NATIVE host link command mode 10- No protocol. (For creating user own custom protocol. IMPORTANT : i. Please note that if you set the protocol to other than the "Native" (mode=5) or "Auto" (mod e=0) that serial port will no longer respond to commands from i-TRiLOGI and you will encounter "Communication Erro rs" when you try to perform any communication using i-TRiLOGI with that serial port. You can still use the other unaffected serial port (e.g. COMM3, RS485) that support host link commands. ii. For all Nano-10, FMD series, and F-series PLC (as well as the legacy T100M series PLCs with firmware revision r42 or above), setting the protocol mode to NATIVE (mode=5) disables support for point-to-point communication. Also, the wildcard FCS (i.e. 00) is not allowed in multi-point format in this mode. This is to ensure the maximum data integrity by accepting only commands that are fully formatted with correct FCS error check. Note that this means i-TRiLOGI's "Detect ID" function will not work since the PLC with protocol mode =5 will not respond to point-to-point protoc ol "IR*". You will have to manually enter the ID into i-TRiLOGI login dialog box to communicate with the PLC. iii. To regain communication with the serial port that has been changed by SETPROTOCOL command, you will have to execute another SETPROTOCOL function that set it to mode 0 or 5 (assuming it has been wri tten into the program), or you must reset the controller by turning OFF the power and then ON again. If you execute a SETPROTOCOL using the 1ST.Scan then you must turn on DIP switch #4 before powering up the PLC so that the SETPROTOCOL command will not be

17. Chapter 1 I-TRiLOGI Setup Guide 1-4 6. Then you must confirm that the re commended version of Java is already installed (version 1.4.2). If it is installed, click ‘Next’ to continue. Otherwise, cancel the installation and see section 1.3 Install Java Run Time Enviroment JRE 1.4.2_19

104. Chapter 7 7-9 When you click on an icon, for example, the icon will change to a bright yellow color to show you the element type that you are creating. At the same time, an I/O table should appear on the screen with a light beige-color background. The I/O table ac ts like a pop-up menu fo r you to pick any of the pre-defined label name for th is contact. This saves you a lot of typing and at the same time eliminates typo errors that co uld result in a compilation failure. You should spend a few minutes to follow t he "Ladder Logic Programming Tutorial" on the steps needed to create a ladder program. As mentioned previously, the ladder editor is intelligent and will only accept an action that can result in the creation of a correct ladder element. Otherwise it will simply beep and ignore the command. UNDO Circuit Editing – If you have wrongly inserted or deleted an element and wish to undo the mistake, you can either select "Undo" from the "Edit" menu or press <Ctrl-Z> key to undo the last step. The undo buffer stores the last 10 editing steps. You can also choose to abort all t he operations on the current circuit by selecting "Abort Edit Circuit" to abort all changes made to the current circuit. 7.4.2 Create Ladder Circuit Using The Keyboard Users of existing TRiLOGI version 3.x or 4.x who are familiar with creating ladder programs using the keyboard will be deligh ted to know that they can still create

106. Chapter 8 Chapter 8 TRiLOGI Main Menu Reference

110. Chapter 8 8-4 non-English I/O labels your program will mo st likely fail to compile when it is saved as a ".PC5" file, since the I/O labels are converted to ASCII and are partially trancated. Thus, it is important to keep the original copy of your .PC6 program so that you can work on it to resolve the unicode conversion issues. 8.1.5 Open (Local Drive) / Save As (Local Drive) For TL6 Application (not Applet) you can open or save a file from/to the local harddisk. You will be presented with the typi cal file dialog prov ided by your O/S. This command however is not available to the TL6 Applet since an applet does not have the right to access local hard disk resources. The default file extension for opening a i-TRiLOGI file is ".PC6". This signals to the TL6 application that the file is in Un icode format and TL6 will then load it accordingly. However, TL6 is also able to read ".PC5" files created by older TL5 applications. TL6 assumes that all ".PC5" files are stored in ASCII format and will load it accordingly. To display ".PC5" files in the file dialog, simply enter the string "*.PC5" in the "File Name:" text field and press <Enter>. The window will now display only files with "*.PC5" extension. You can then navigate to the folder that contains the ".PC5" files to pick the file you want to open. The default file extension for saving a i-TRiLOGI file in TL6 is ".PC6". This signals to the TL6 application to save the data in Unicode format. Unicode is required to store international characters which ca nnot be properly saved in the ASCII format used by TL5. However, you may still save the currently opened i-TRiLOGI file in TL6 to a file with an extens ion ".PC5", which will then instructs TL6 application to save the file in ASCII format. Files save d with ".PC5" extension may then be opened using older TL5 applications. Import Notes: 1. Since “.PC6” files are saved in Unicod e while “.PC5” files are saved in ASCII code format, the two files type are NOT interchangeable. Therefore, you must not simply change a file name extension from “.PC5” to “.PC6” via Windows File manager and then attempt to open it from TL6. Doing so will cause TL6 to complain that it is not a valid i-TRiLOGI file. 2. Any Unicode characters used in the program that cannot be represent by 8- bit ASCII code will be lost when the file is saved in ".PC5" format and it is not recoverable. So if you use non-English I/ O labels your program will most likely fail to compile when it is saved as a ". PC5" file, since the I/O labels will be converted to ASCII and partially truncate d. Thus, it is important to keep the

111. Chapter 8 8-5 original copy of your .PC6 program so that you can work on it to resolve the Unicode conversion issues. 8.1.6 View Protect / Un-Protect This feature allows you to prevent othe rs from viewing a pre-defined range of ladder logic and custom functions. When you select "View Protect" command, you will be asked to enter an unlocking password, a range of ladder logic starting from circuit #1, as well as a range of custom functions whose content you wish to prevent others from viewing, as follow: The moment you click on the "View Protec t" button, you can no longer view or print the protected range of ladder circ uits and custom functions. When you save the view-protected program, it will be saved in an encrypted format and it cannot be opened using older version of i-TRiLOGI software. However, you will still be able to add new ladder circuits and custom functions to this program as well as modify those unprotected ladder circuits and custom functions. Of course, you will still be able to compil e, simulate and transfer the protected program to the PLC as usual. A view-protected file can be unprot ected by selecting the "Un-protect" command from the "File" menu and su pplying the unlocking password. Note that this unlocking password is strictly fo r un-locking the viewing restriction and it has nothing to do with other username and/or password required for interacting with the PLC. This View Protection command is extrem ely useful for OEMs who wish to allow end users of their equipment to modify or append to the PLC's program for ease

203. Chapter 11 Chapter 11 TBASIC Statements, Functions, Operators and Variables

56. Chapter 4: Using TLServer 4-13 case the simple <EMAIL> tag method described on the PLC's manual will not work since the PLC does not handle authentication with the SMTP server. It is possible to program the PLC to ha ndle unencrypted authentication with the SMTP server using complex TBASIC stat ements in order to send email (see examples described on the forum un der "Frequently Asked Questions"). However, to simplify programming effo rt, we have introduced a new, "Email Relay Server" feature to TLServer starti ng from version 3.17. The "Email Relay Server" feature is for the TLServer to ac t as a pseudo, unauthenticated SMTP mail server to the PLCs and receive the emai l data from the PLC. It then in turn connects to an authenticated SMTP serv er and "relay" the email data to the actual SMTP server. In order to use this feature, the PLC would configure its SMTP IP address to be that of the IP address of the PC that is running the TLServer, and the SMTP port to that of the "Port # to Relay PLC Email". The Email Relay Server can be any PC on yo ur LAN that runs the TLServer that is already configured to work with an external SMTP mail server (whether autheticated or not). Your PLCs on t he same LAN can then s end their email via this TLServer instead of directly to th e external SMTP server. This could be advantages in terms of ease of prog ramming and also should the company decide to change its ISP or SMTP server provider, only the TLServer needs to be re-configured and the PLCs on the network need not be configured individually to address the change. 4.4.2 Configure And Test SMTP EMail Server NEW!: TLServer version 3.17 offers a whole new look to the Email Setup, which has all the same features as before plus a couple of additions, including Port No. specification, optional Authentication an d a Test Email function to test the settings you have entered. See below for descriptions of the additions. To setup the server to handle email requ ests, click on the "Setup Emails" button on the TLServer to open the following dialog box:

78. Chapter 6 6-4 6.2 Ladder Logic Programming Tutorial: STEP 2 1. Timer table has an extra column "Set Value" located to the right of the "Label Name" column. 2. After you have entered the label name "Duration" for Timer #1, a text entry box is opened up at the "Set Value" location of Timer #1 for you to enter the SV for the timer. SV range is between 0 and 9999. Enter the value 1000 at this location. 3. For a normal timer with 0.1s time base, the value 1000 represents 100.0 seconds, which means that the "Duration" timer will time-out after 100.0 seconds. If the timer had been configured as "High Speed Timer" using the TBASIC "HSTimer" command , then the time-base would become 0.01s, meaning the value 1000 represents only 10.00 seconds. 4. We are now left to define the se quencer, "Seq1". The sequencer is an extremely useful device for implement ing sequencing logic found in many automated equipment. i-TRiLOGI supports 8 sequencers of 32 steps each. Each sequencer requires a "Step counter" to keep track of the current step sequence. The first 8 counters in the counter tabl e double as the step counters for the 8 sequencers. These sequencers must be named "Seq1" to "Seq8" if they are to be used, i.e. Counter #1 to be named as "Seq1", Counter #2 as "Seq2", etc. However, any counter not used as sequencer may assume any other name (up to a maximum of 10 characters) if they are used as ordinary counters. If you are at the "Timers" table, pres sing the right cursor key again will bring up the "Counters" table. Enter the name: "Seq1" at the label column for Counter #1. Press <Enter> and the te xt entry field will be opened at the "Set Value" column. For now, let's ent er a preset value of "4" for "Seq1".

80. Chapter 6 6-6 2. Now insert the first element by left-clicking on the icon. The icon will change to a bright yellow color to show you the element type that you are creating. At the same time, an I/O tabl e should appear on the screen with a light beige-color background instead of the normal light blue background. The I/O table now acts like a pop-up menu for you to pick any of the pre- defined label names for this contact. Note: In i-TRiLOGI version 6.x, if you pick any undefined I/O you will be prompted to enter the label name an d what you entered will automatically be updated in the I/O table. 3. The contents in the table are not no rmally meant to be edited at this moment . Scroll to the "Input" table and click on the label name "Start" and a normally-open contact will be created at Circuit #1.

92. Chapter 6 6-18 7. The logic states of any I/O can be displayed on the ladder diagram directly. An Input, Output, Relay, Timer or Counte r contact that is turned ON will have its label name highlighted in the ladder diagram. This feature helps greatly in debugging and understanding the logi cal relationship between each I/O. For example, from the above figure, we can see clearly that the "Self- latching" circuit for relay "Run" works as intended: when we first turn ON the "Start" input, "Run" will be energized and its contact which is parallel to "Start" will hold itself in the ON state, even if we subsequently tu rn OFF the "Start" input by releasing the button. 8. The timer coil "Duration", being connecte d in parallel to "Run" relay, will also be energized. However, its contact will only be closed after 100 seconds (when its present value counted to 0). To break the latched On "Run" relay, we must energize the "Stop" input mom entarily to break the "power" flow. Try it now. 9. Let's restart the system by turning ON the "Start" input momentarily again. Next, we want to turn ON the "Manual" input. Move the mouse pointer to the "Manual" input and then press the right mouse button. "Manual" input will be

94. Chapter 6 6-20 14. This screen shows the values of TBAS IC variables A to Z and many other data. It also provides a simulated 4 lines LCD display that show case the action of the SETLCD statement contained in Custom Function #1. As you can see, the value of variable X used in the Custom function is also shown in the variable section. The value of X is converted by the STR$(X) statement into a string and displayed after the text string "Cycle Count = " at line #1, column #1 of the LCD area. Summary We have completed this hands-on se ssion and have successfully created a simple ladder +BASIC program. We have also performed real time simulation to test the program's functionality. By now you would probably have a good appreciation of i-TRiLOGI's superb capability and ease of use and are ready to include i-TRiLOGI as an integral part of your programming needs.

144. Chapter 8 8-38 2. Analog Outputs (DAC) Calibration In order to calibrate an analog output , you need to set the DAC to a certain value and then use a measuring instrum ent to measure the resulting output voltage (or current, if an AN20MA-2 in terface board is used). The difference between the expected DAC output and measured DAC output is used to compute the calibration parameters for the PLC's analog output. For example, if you wish to calibrate analog output #1 and #2 and using an analog output value of 2048, you first must clear the old analog calibration paramters (using the Ethernet & ADC Configuration Tool -> Advanced Config), then write a program into your PLC to execute the following two statements: SETDAC 1, 2048 SETDAC 2, 2048 Your PLC will then output an uncalibrat ed analog output voltage on the DAC which you can then measure with a precisio n voltmeter. If your analog outputs are configured for the 0 to 5V range, then ideally at 2048 you expect the DAC to output a voltage = 2048/4096*5.000 = 2.500V. However, assuming that your precision voltmeter measures a voltage of 2.510V at DAC #1 and 2.488V at DAC #2, yo u will then need to convert the two measured readings to the range of 0-4096 and then enter into the "Measured DAC" fields. For DAC #1, the measur ed reading = 2.510/5 x 4096 = 2056 and for DAC #2, the measured reading = 2.48 8/5 x 4096 = 2038. Enter these two values into the table as shown in the above diagram. After you have entered all the above parameters, you can then click on the "Calibrate Analog Outputs" button to star t calibration of the analog outputs. The program will compute the calibration pa rameters based on the "SETDAC" and

168. Chapter 9 9-16 contact will turn ON until the next incr ement of the sequencer. This contact can be used to indicate that a program ha s completed one cycle and is ready for a new cycle. Accessing individual steps of the sequencer is extremely simple when programming with i-TRiLOGI. Simply create a "contact" (NC or NO) in ladder edit mode. When the I/O window pops up for you to pick a label, scroll to the "Special Bits" table as follow: The "Special Bits" table is located afte r the "Counters" table and before the "Inputs" table. Then click on the "SeqN:x" item to insert a se quencer bit. You will be prompted to select a sequencer from a pop-up menu. Choose the desired sequencer (1 to 8) and another dialog box will open up for you to enter the specific step number for this sequencer. Each step of the sequenc er can be programmed as a contact on the ladder diagram as "SeqN:X" where N = Sequencers # 1 to 8. X = Steps # 0 - 31. e.g. Seq2:4 = Step #4 of Sequencer 2. Seq5:25 = Step #25 of Sequencer 5. Although a sequencer may go beyond Step 31 if you define a larger SV for it, only the first 32 steps can be used as co ntacts to the ladder logic. Hence it is necessary to limit the maximum step number to not more than 31.

187. Chapter 10 10-15 Select either item to create a CusFn: " D : [CusFn] - Custom created Function" or " E : [dCusF] - Diff. Up Custom Functn" You will be required to enter the selected custom function number from 1 to 256. Note that a CusFn created using " E :Diff. Up Custom Functn[dCusF]" is a "Differentiated Up" instruction. This means that the function will be executed only once every time when its execut ion condition goes from OFF to ON. Nothing will happen when its execution condition goes from ON to OFF. On the other hand, using "D: Custom cr eated Function [CusFn]" will mean that the CusFn will be executed every scan as long as its execution condition is ON.

216. Chapter 12 Chapter 12 TBASIC Keyword Reference

232. Chapter 12 12-16 returns a 1 if an ACK is received , and 0 if no ACK is received after time out. Parameters : i2cslave = The 7-bit slave address that the CPU is writing to. dmstart = The starting index of the DM[ ] that contains the first data byte count = number of byte data to send (maximum is dependent on the slave). Example : DM[5]= 12: DM[6]= 34 : DM[7]= 56 I2C_WRITE &H60,5,3 I2C_STOP Following the START bit, the CPU will write the 7-bit slave address &H60 (=110 0000 binary) and a R/W bit set to 0, followed by the byte data stored in DM[5], DM[6] and DM[7]. Note : This command does not au tomatically generate the I2C STOP bit, this is to allow the CPU to perform a I2C_READ following a I2C_WRITE. I2C READ after WRITE is commonly encountered in I2C protocol which requires using the I2C_WRITE to set the internal pointer address in the slave device and then followed by the I2C_READ command. Therefore, if your command in volves only I2C_WRITE, you must end the WRITE command by executing a I2C_STOP statement. See Also : I2C_READ , I2C_STOP Note: 1. This command is applicable only to Nano-10 and FMD PLC models with firmware >=r74 and I2C interface. 2. This command is ignored by i-TRiLOGI simulator.

329. Appendix 4 A4-5 DM[3991]=DM[3991]+1 'increment the timer ENDIF RETURN ENDIF IF TESTIO(dialModem)=0 RETURN: ENDIF ' If DM[3990] > 0 it means a dialing action has started. ' If DM[3990] > 30 it means more than 30 seconds has passed ' and connection still not established, then retry. IF DM[3990]=0 ' Use this DM as a flag WHILE INCOMM(1)<> -1 ' clear whatever data in serial buffer first. ENDWHILE PRINT #1 D$ ' Dial the number DM[3990]=1 RETURN ENDIF A$ = INPUT$(1) IF LEN(A$) = 0 DM[3990]=DM[3990]+1 ' also use it to track the time-out IF DM[3990] = 28 ' 28 seconds has lapsed. PRINT #1 "ATH" ENDIF IF DM[3990]>=30: DM[3990]=0: ENDIF RETURN ENDIF SETLCD 4,1,A$ IF STRCMP(MID$(A$,2,7),"CONNECT")=0 ' is connected DM[3990] = 0 ' for next round of connection DM[3991] = 0 ' reset timer for hang-up modem use SETIO Connected ' set an I/O bit to indicate connection ENDIF All you need to do is to copy and paste this custom function to your own Ladder+BASIC program, then create an I/ O with label name "DialModem" – this

330. Appendix 4 A4-6 may be an input, output, relay, timer or counter contact. The moment this I/O bit "DialModem" is turned on, the PLC will begin to execute the sequence of dialing the remote mode m, waiting for a successful connection and then turning on an I/O bit with the label na me "Connected". If the dialing cannot be completed within 30 seconds, this custom function will hang up and then re-dial. The process will be repeated indefinitely until either a successful connection is made or if the "DialModem" i/o has been turned OFF. To disconnect from the modem (hang up), your PLC program just have to turn off the "DialModem" I/O bit and the ab ovementioned custom function will automatically perform the action of hanging up the modem. Note: Since the PLC does not have a carrier detect (CD) connection to the modem, therefore if the connection is lo st after a successful initial connection, the PLC would have no way of knowing it immediately. Your program would have to detect this condition (e.g. if it sends a file service command and does not receive a "<OK>" acknowledgement string from the host). Once the PLC notes that the connection is lost, it ca n re-establish the connection by simply turning off the I/O bit with label name "Connected". (say, by executing the "CLRIO Connected" statement). As long as the "DialModem" I/O bit is on, the custom function will re-dial and atte mpt to make another connection if it notices that the "Connected" bit has been turned OFF for whatever reason.

42. Chapter 3 3-14 If not, then follow steps 2-4 from the Program Transfer section above to login to TLServer or FServer. The above monitoring window will appear after successful login.

43. Chapter 4: Using TLServer Chapter 4 USING THE TLSERVER – WEB SERVER FOR TRILOGI

45. Chapter 4: Using TLServer 4-2 When a client program such as i-TRiLOGI want s to read from or write to a PLC, it sends a command to the TLSe rver using the TCP/IP protocol transported via the Intranet, the Internet or a local host connection. The TLServer, upon receiving the command, will carry out the actual reading or writing to the PLC via the PC's RS232 or RS485 port. The data received from the PLC is then relayed back to the client program via TCP/IP protocol. TLServer is also a Web Server which se rves up web pages that contain the i- TRiLOGI Java Applet to enable you to use any Java-enabled Web browser to access the PLC without the need to inst all a local copy of the i-TRiLOGI application software. TLServer 3.17 now supports large font size increment so that it can display larger graphic on high resolution monitor on small screen. Note: TLServer also provides " File and Email Services " to the PLC. That means that a PLC can send a command to the TLServer to open a file and sa ve its data into the PC's harddisk. TLServer 3.17 now also features an "Email Relay Server" to help PLC send out emails via authenticated SMTP servers. The new Email Service works differently from the original email function provided in TLServer 1.0 in that TLServer does no t poll the PLC, instead it is the PLC that initiates an email request asynchronously. This makes it possible for a PLC to dial- in via a modem to request the TLServer to help it send out an email without demanding a constant connection the TLSe rver. However, the original email function is still supported in Version 3.x because that has the advantage of being able to service email requests for multiple PLCs linked via the RS485 network. When TLServer is first started, it will query the operating systems for the IP addresses of the computer that it runs on . (It may take a while if the O/S is slow to return the IP address). It will then display the obtained IP addresses (maximum of two) on the TLServer fron t panel so that the user can quickly determine the IP addresses that they ca n use to access the PLC. The following are some possible IP address scenarios: 1. If the computer is not linked to any network or the Internet and does not have any network adapter installed, then only the local host IP address will be displayed, e.g. 127.0.0.1: 9080 where 9080 is the port number). Note: regardless of whether your PC is networked or not, the local host IP address: 127.0.0.1 is always availabl e to the client program running on the same PC where the TLServer is running, even though it may not be displayed on the TLServer's front panel. ( i-TRiLOGI or TRi-ExcelLink are all

70. Chapter 5 5-1 5 RUNNING THE INTERNET TRILOGI CLIENT 5.1 Starting The i-TRiLOGI Application Basically there are 3 methods in which you can start the i-TRiLOG I application, as follow: 1. If the i-TRiLOGI and JRE has been pr operly installed on your PC, you can just click on the "Start" button and select "i-TRiLOGI 6.x" in the "i-TRiLOGI 6" as follow: 2. You can also open My Computer and open the folder: C:\TRiLOGI\TL6\, then double click on the file "TL6.bat" to start i-TRiLOGI Application. Note that during the installation of the la nguage pack the TL6.bat file will be replaced by the "TL6.bat" specific to that installed language. E.g. For running TL6 with Chinese language su pport, the TL6.bat will contain the following command line: java -Duser.language=zh -jar TL64.jar The command line above forces the i-TRILOGI to run with the Chinese language (Zh) encoding. As such, do not start the i-TRiLOGI application by double-clicking on the "TL64.jar" fi le directly since that will only run i- TRiLOGI in the US English language instead of the language of choice. 3. The third alternative is to run the program from DOS command line: First, run the MS-DOS prompt (aka Comman d Prompt in Windows XP) and then navigate to the directory "C:\TRiLOGI\ TL6" (assuming that is the folder

132. Chapter 8 8-26 For Windows XP or Vista users, you can re solve the IP address as follows: First, launch the “Command Prompt” window . Then enter the command nslookup <smtpserver name>” to get the IP address. An example is shown below where the IP address of mail.sbcglobal.net is resolved to the IP address: “207.115.36.120”: Windows users may also search the Internet for a free “host.exe” tool that lets you resolve the IP address from a given domain name (one host.exe tool that we found to work was downloaded fr om http://pigtail.net/LRP/dig/). For example, executing the command line: “hos t mail.sbcglobal.net” will resolve its IP address. (Of course you can only use this smtp server provided your ISP is SBC, almost no SMTP server will relay emails fr om a client that is not one of its own subscribers). If you do not plan to use the FServer to send out emails yet, then you can leave the default SMTP Server IP Address = 0.0.0.0. You can change the settings anytime later when you need it. 4. DNS Server IP Address DNS (Domain Name Server) allows the FServer to contact a remote location by means of domain name instead of IP Address. The DNS takes in the given

139. Chapter 8 8-33 Proportional Error = (3230)/3277 = 0.985658 Multiplication factor required to correct this error = 1/0.985658 = 1.0146 = (1+ 146/10000) => x = +146 To compensate for this error, enter a value of 146 in the “ADC Calib.” for Ch 8 and save it to the PLC. After the PL C has rebooted, the CPU would apply the multiplication factor of 1.0146 to the re adings it received, which would correct the reading to: 3230 x 1.0146 = 3277. Notes: a) We have created an MS-Excel spreadsheet file “AnalogCalibration.xls” to facilitate the computations of the co rrection factor, X, used in the ADC and DAC Calibration. This file can be downloaded from the following web page: http://www.tri-plc.com/appnotes/F-series/AnalogCalibration.xls b) Changes to the ADC calibration data only take effect after the PLC has been cold-booted. You can either powe r cycle the PLC or simply check the “Reboot PLC After Save” checkbox and the PLC will re-boot after you have transferred the parameters to it. 3. ADC Zero Offset

171. Chapter 9 9-19 LED3, LED4, LED4, LED3, LED2, LED1, all LE D OFF and then restart the cycle again. This can be easily accomplished with the program shown below. The 1.0s clock pulse bit will advance (i ncrement) Sequencer #2 by one step every second. Sequencer 2 should be defi ned with Set Value = 8. Each step of the sequencer is used as a normally open contact to turn on the desired LED for the step. A "Stop" input resets t he sequencer asynchronously. When the sequencer counts to eight, it will become Step 0. Since none of the LED is turned ON by Step 0, all LEDs will be OFF.

176. Chapter 10 10-4 b) Select a Variable If the selected text is a variable name or a defined name in the #Define table, then the lower pane will display the current value of the selected variable! The value is obtained from the simulato r if i-TRiLOGI is currently disconnected from any TLServer or F-Server. If i-TRiLOG I is currently connected to a TLServer or F-server, then the program will retrieve the current value from the connected PLC. In the following example, variable DM[ 2479] has a current valu e = 197 and it is being used in Custom function #3, 4, 7 and 24.

177. Chapter 10 10-5 c) Select a Custom Function Name If the selected text is the name of a custom function, a special read-only popup window will appear which displays the content of the selected function. This enables the programmer to view t he code of another custom function CALLed by this function without leaving the current function. You can also edit the selected custom func tion by right-clicking on the selected name and select "Open" from the popup menu, as shown below.

241. Chapter 12 12-25 ch - This refer to the communica tion port #. Please refer to the target PLC for details. x$ - contains a valid host li nk command in multi-point format, excluding the Frame Check Sequence (FCS) and the terminator characters (* an d CR). NETCMD$ function will automatically compute the FCS and append to the end of x$ and together with the terminator characters will be sent to the other PLC via COMM #ch. Note : 1) If the target PLC does not respond then this function returns an empty string. 2) This function checks the FCS of the response string, and if the FCS is wrong it indicates an error in the serial reception and it will return an empty string. Examples : A$ = NETCMD$(3, "@05RI00") Comments : To read the Input cha nnel #0 of the PLC with ID = 05 connected to COMM #3 of this PLC. The response string will be assigned to A$. Special : If the last character of x$ is a “~” character, NETCMD$ will send out the string without t he ‘~’ character. It will not append the FCS and ‘*’ to the ou tgoing string and it will not send out the carriage return (ASCII 13) character. It will also NOT check the response string for FCS. This allow NETCMD$ to be used to interface to third-party ASCII devices with different command/response formats. E.g. A$ = NETCMD$(3, “Hello World~”) The string “Hello World” will be sent out of serial COMM port #3. A$ will receive the full returned string without applying any FCS check on the return string. 12.39 OUTCOMM n, x Purpose : This statement can be used to send an 8-bit byte of data ' x ' via Comm port #n. This comm and is added because PRINT#n command cannot be used to send out CHR$(0). Zero is

109. Chapter 8 8-3 Simply double-click on the desired file or select the file you wish to open and click the "Open" button to open the i-TRiLOGI file. Sub-directory: The MKDir button allows you to create a sub-directory on the server to organize your files. Subdirecto ry names always end with a "/" character. If you open a subdirectory its contents will be displayed in the file window. To return to the parent directory from a su b-directory, you simply double-click on the symbol. 8.1.4 Save As (TLServer 3) Use this command if you wish to save the currently edited i-TRiLOGI file to the TLServer 3.x using a different filename. You will be prompted to enter the Username/Password (and the IP address if it is a TL6 application) to gain access to TLServer. Once authenticated, the network file dialog similar to that described in "Open (TLServer 3)" will be opened for yo u to enter a file name or select a filename to overwrite. The default file ext ension for file saving is ".PC6" which will save the file in Unicode format to the TLServer user folder. However, you may also save the file with an extension ".PC5" , in which case the TLServer 3.x will then save the i-TRiLOGI file in ASCII format. Files saved with ".PC5" extension may be opened by older TL5 applications. Important Notes: Any non-ASCII characters used in the program file will be lost when the file is saved in ".PC5" format an d it is not recoverable. So if you use

114. Chapter 8 8-8 the ".csv" file and the I/O table content s will automatically be displayed in an Excel spreadsheet. This provides limitless possibilites for printing the contents of the I/O Table and for integrating them in to other documents. To export the I/O Table, just choose the "I/O Tables" option from the Print Control Panel and click on the button, as shown in the Print Co ntrol Panel below. You will then be prompted to save the I/ O Table as a ".csv" file. NOTE: You can select the range of I/Os you want to export to a ".csv" file, just like you can select the range of I/Os you want to print. Export Custom Functions Now you can export custom functions to a ".txt" file that can be opened any text editing program. It is best to use a text editor that interprets carriage returns as new-line characters as well so that ea ch custom function is displayed as it would be in the i-Trilogi Custom Function Ed itor instead of as one long line that is very difficult to read. A good editor to use is Wordpad or Microsoft Word. To export Custom Functions, just choose t he "Custom Functions" option from the Print Control Panel and click on the button, as shown in the Print Control Panel below. You will then be pr ompted to save the Custom Functions as a ".txt" file.

117. Chapter 8 8-11 8.2.6 Find <Ctrl+F> The Find command allows you to quickl y locate a ladder logic circuit that contains a particular label name. This is useful for searching fo r the activity of a particular I/O in the program. The Find command can also be used to search for a keyword in a TBASIC program. When th is command is executed you will be further prompted to select the options of either searching for a ladder logic label or finding a text in a Custom Function. Find Ladder element: You can enter into t he the text field a string that partially or fully matches the label name you wish to locate. You can also press the <F2> key to open up the I/O table and pick the label name from the I/O table. Find Text in CusFn: It is now possible to search for text within a custom function and when the option "Find Text in CusFn" is selected, the custom function editor window will open automatically to the fi rst custom function. You can either search for text within the current custom function (local search) or in all of the custom functions in your program (global search). To do a local search, simply type the text in the command line below the "Find" and "Find All" buttons and then click the "F ind" button. If the te xt is found in the current custom function, it will be highligh ted in the text editor as shown below. Also, the text "Find only in this CusF" will be displayed below the command line in the search area, indicating a local search. Each time the "Find" button is clicked, the next instance of the search text will be highlighted until the text cant be found anymore. At this point the message in the search area will change to "Text Not Found" and the next time "Find" is cli cked, the first result will be highlighted again.

205. Chapter 11 11-2 To make a program visually more compact, the colon symbol ":" may be used to act as delimiter. e.g. IF A > B THEN C = D*5 ELSE C = D/5 ENDIF may be written more compactly as IF A >B : C=D*5:ELSE:C=D/5:ENDIF 11.2 TBASIC Integer Constants, Variables & Operators The TBASIC compiler in i-TRiLOGI supports full 32-bit integer computations. However, only variable A to Z are 32 bits in length which allow them to represent number between -231 to -231, the remainin g system variables and data memory DM[n] are all 16-bit variables which means that they can only store number between -32768 to +32767. However, all numerical computations and comparisons in TBASIC are carried out in 32-bit signed integer, regardless of the bit-length of the variables involved in the numerical expression. 11.2.1 Integer Constants These may be entered directly in decimal form, or in hexadecimal form by prefixing the number with the symbol "&H". e.g. 12345678 &H3EF =1007 (decimal) If the result of an expression is outside the 32-bit limits, it will overflow and change sign. Care must therefore be exercised to prevent unexpected result from an integer-overflow condition. A constant may be used in an assignm ent statement or in an expression as follow: A = 12345 IF A*30 + 2345/123 > 100 THEN ....ENDIF

207. Chapter 11 11-4 appended to DM[] variables as follows: DM[1]_Current_status_of _product1 - refers to variable DM[1]. 3. Starting from version 6.45, the DM[1 ] to DM[4000] can also be used as 32- bit variables DM32[1] to DM32[2000] in the following manner: DM[1] & DM[2] == DM32[1], DM[3] & DM[4]= =DM32[2]... DM[2N-1] & DM[2N] = DM32[N]. If you require lots of 32 bi t variables it may be simpler to use only the DM32 and not the 16-bit DM. If you mix the use of both DM and DM32 then you need to manage the memo ry properly to ensure that they don't overwrite each other memory space. The simulator fully support the use of DM32 variables in any expression. However, for the actual PLC only th ose with firmware r78 supports DM32 variables. PLC with older firmware cannot directly use DM32 in the program. E.g. DM32[100] = DM[1] * A 4. System variables. These are special integer variable s that relate to the PLC hardware, which will be described in the next section. 11.2.3 System variables: NOTE: All of the following System Variables can have comments appended to them with the same format as described in section 5 (Integer Variable Comments). a) Inputs, Outputs, Relays, Timers and Counters Contacts The bit addressable I/Os elements are or ganized into 16-bit integer variables INPUT[n], OUTPUT[n], RELAY[n], TIMERBIT[n ] and CTRBIT[n] so that they may be easily accessed from within a CusFn. T hese I/Os are arranged as shown in the following diagram:

37. Chapter 3 3-9 Program Transfer All steps are the same whether the PLC is connected via serial port or Ethernet unless otherwise specified. 1. Select “Program Transfer to PLC” from the “Controller” menu (or press CTRL + T on the keyboard). 2. The “Login to TLServer” window wi ll open as shown below. Although it mentions TLServer, it is ac tually used to login to either server (TLServer or

75. Chapter 6 6-1 6 LADDER LOGIC PROGRAMMING TUTORIAL Your Assignment: Creating Your First Ladder Logic Program In this tutorial, we would like to create a simple program as shown below:

93. Chapter 6 6-19 "stuck at "ON" state even after you have released the right mouse button. Click on "Manual" button using the right mouse button again and it will be turned to OFF. 10. When "Manual" input has been turned ON, the running lights should stop. This is because the normally-closed contact of the "Manual" input in Circuit #2 is now turned OFF and the 0.5s clock pulse could not trigger the [AVseq] function anymore. 11. If you now left-click on the "Step" inpu t, the running lights will move one step at a time in response to your mouse cl ick. Observe the Seq1:x contact with respect to the counter value of Seq1 and the logic of this circuit become very clear instantly. 12. Observe that the timer "Duration" continues to count down every 0.1 second, and when it reaches 0, the "Duration" outp ut coil label will be highlighted. You can use this timer to stop the pr ogram by connecting a N.C. "Duration" contact to Circuit #1. This is left as an exercise for you! 13. You can also observe the execution of the Custom Function #1 by clicking on the "View" button on the "Program mable Logic Simulator" screen and the following window will appear:

125. Chapter 8 8-19 will be captured into these two buffer areas. The data must be entered in “comma-delimited” format as described below: 1. Integer EEP Buffer Format Integer EEPROM data should be entered in the format [address], [data] and a line break. E.g. to store decimal da ta 12345 (equivalent to 3039 in hex) into address 10, enter the following text into the Integer EEP Buffer area. 10, 12345 or, in hexadecimal data format: 10, &H3039 2. String EEP Buffer Format String EEPROM data should be entered as $[address], [text string]. E.g. to store the string “Test Message 10” into string a ddress 5, enter the following text into the String EEP Buffer area: $5,Test Message10 $8,Rm Temp=25\DFC If you need to store a non printable char acter or ASCII character which is > 127 in value into the string EEP buffer, yo u can enter it as an “escape sequence” which is in the format of “\XX”. The backslash character “\” denotes that this is an escape sequence, and XX is the hexa decimal value of the character. E.g. character A can be written as “\41” and ch aracter Z can be written as “\5A”. In the second example above, the \DF char acter is ASCII 223 which on an LCD216 or LCD420 will be displayed as a 'degree' symbol. Note: 1. Normally when an EEPROM is in erased state, all it memory bits contain binary ‘1’ and when you read them from the EEP ROM as string, they will be returned as “\FF”. 2. To prevent disrupting communication with the PLC, the strings to be written to EEP must not contain any of the following characters: ASCII 0 (“\00”), ASCII 10 (“\0A”) and ASCII 13 (“\0D”).

141. Chapter 8 8-35 The actual DAC output = 5.030V x 0.994 = 5.000V 5. DAC Zero Offset If you plot the line graph for the output voltage versus the DAC set value, the line should normally pass through the origin. But if there were any zero offset error, then the line would be above or below the origin. The DAC output on the F-series PLC shou ld not have any zero offset error and you normally should just leave these fields set to “0”. However, if for any reason there is a need to apply a zero offset error correction, you can enter a value between –100 to +100 into the “DAC Zero Offset” field. The CPU would add the zero-offset value you enter into this fiel d to the “X” in the “SETDAC n, x” statement and only send the sum to the actual DAC hardware. 6. A/D Moving Avg This field lets you define the number of points of moving av erage that the F1616- BA CPU firmware uses to compute the va lue returned by the ADC(n) function (for F-series PLC users, please refer to Chapter 5.2.5 of the User Manual for an explanation of moving average). A larger number of moving Average points has the positive effect of filtering out large noise spikes seen at t he analog input, but the disa dvantage is that the PLC would be slower in noticing a sudden step change at the analog input. If you specify a moving average of 1 point, that means no moving average will be used and the ADC(n) function will return the most recently sampled data at the analog input #n.

162. Chapter 9 9-10 Each time when the execution condition of a [DNctr] function changes from OFF to ON, the present value of the designated counter is changed as follow: a) If the counter's present value (PV) is inactive, load the counter register with the "Set Value" (SV, defined in the Counter table) minus 1. b) If the counter’s present value (PV) is already ‘0’, then load the counter’s PV with the SV defined in the coun ter table and turn on the counter's contact (also known as the completion flag). c) Otherwise, decrement the counter PV register by 1. Increment Counter [Upctr] Each time when the execution condition of an [Upctr] function changes from OFF to ON, the present value of the designated counter is affected as follow: a) If the counter is inactive, load the counter register with the number '0001'.

165. Chapter 9 9-13 Note that [ILoff] is the only function th at does not need to be energized by other program elements. When you use one or more [ILock] functions, there must be at least one [ILoff] function before the end of the program. Otherwise the compiler will warn you for the missing [ILoff]. The logic simulator always clears the Interlock at the end of the scan if you omit the [ILoff] function. You can program a second or third level Interlock within an Interlock section using a few [ILock] function s. However, you only need to program one [ILoff] function for the outermost Interlock sectio n, i.e. [ILoff] need not be a matching pair for an [ILock] function. 9.3.6 Differentiate Up and Down [d DIFU] and [d DIFD] When the execution condition for [dDIFU] goes from OFF to ON, the designated output or relay will be turned ON for o ne scan time only. After that it will be turned OFF. This means that the function generates a single pulse for one scan time in response to the ri sing-edge of its execution condition. When its execution condition goes from ON to OFF nothing ha ppens to the output or relay that it controls. On the other hand, when the execution condition for [dDIFD] goes from ON to OFF, the designated output or relay will be turned ON for one scan time only. After that it will be turned OFF. This me ans that the function generates a single pulse for one scan time in response to the trailing-edge of its execution condition. When its execution condition go es from ON to OFF, nothing happens to the output or relay that it controls.

211. Chapter 11 11-8 11.2.6 Integer Variable Comments With i-TRiLOGI version 6.2 and above, you can now attach comments to any variable/register name of any length to make program easier to read. The compiler will ignore any alphanumeric charac ters (A to z, 0 to 9 and ‘_’) that are attached behind the variable name followi ng an underscore character “_”. It is important to understand that by appe nding these comments to variables, no new variables are being created. For Example: "X_Some_Integer" corresponds to "X" An integer variable (such as DM[1]) can have different comments each time it is referenced in the same program beca use the compiler ignores the comments anyways. Although, in most cases it may be best to limit a variable to one comment to avoid potentially overwriting data since no new variables are actually create, as mentioned above. For Example: If an integer variable, DM [1], was named "DM[1]_one_integer" in one part of a program and named "DM[1] _two_integer" in another part of the program, then they will still both refer to DM[1]. If each variation has different integer data, then the data that was st ored in the last variation that was updated will be the data in DM[1]. Then if the previous variation is accessed, it wont contain the data that was originally stored in it. 11.2.7 Variable Define Table (NEW!) With TRiLOGI version 6.42 and higher, it is possible to create a table of variable/constant/expression definitions. Please see section "8. Define" in the Introduction to TBASIC & Custom Functions for more information on how to interface to the Define Table. Here is an example of a possible Define Table :

215. Chapter 11 11-12 behind the variable name following an un derscore character “_”. It is important to understand that by appending th ese comments to variables, no new variables are being created. For Example: "A$_Some_String" corresponds to "A$" (or $$[1]). A string variable (such as A$) can have different comments each time it is referenced in the same program beca use the compiler ignores the comments anyways. Although, in most cases it may be best to limit a variable to one comment to avoid potentially overwriting data since no new variables are actually create, as mentioned above. For Example: If a string variable, A$, wa s named "A$_one_string" in one part of a program and named "A$_two_string" in an other part of the program, then they will still both refer to A$. If each variation has different string data, then the data that was stored in the last variation th at was updated will be the data in A$. Then if the previous variat ion is accessed, it won’t contain the data that was originally stored in it. 11.3.5 Variable Define Table (NEW!) This new feature allows you to define an acceptable name for any variable, constant or even an entire expression. Please see section 9.3 Define Table and 10.2.7 Variable Define Table for more details.

306. Appendix 2 Appendix 2: Application Notes & Programming Examples

322. Appendix 3 Appendix 3: A-3 Troubleshooting Serial Communication

23. Chapter 1 I-TRiLOGI Setup Guide 1-10 English language user may modify the content of their pull down menu and on screen display by modifying the “en_language.txt” file. You can open some of the supplied language files (e.g. English vs. Spanish) to understand how the English language items are translated to another language. When the i-TRiLOGI version 6.x or TLServer 3.x program starts up , the program will automatically try to load the specific la nguage file based on the locale of the user’s operating system and use the fi le content throughout the session. However, if the program fails to find the corresponding language text file, then it will use a set of internally defined English language text strings for its entire menu and on screen display. For English locale user, all i-TRiLOGI 6.x help files are stored in the following folder: “c:\TRiLOGI\TL6\public\Help”. However, if you start TRiLOGI in locale xx, then when you attempt to open an online help fi le, TRiLOGI will first check if there exist a folder “c:\TRiLOGI\TL6\public\xx_Help” . If it finds it t hen the help files will be loaded from this locale-specific fold er. But if it cannot find the “xx_Help” folder it will then load the help files from the default folder: “c:\TRiLOGI\TL6\public\Help”. Hence for those who wish to experiment with providing their own locale specific help fi les, they should copy all the help files from the default folder into the new lo cale-specific “xx_Help” folder and then make changes to files in the new folder . When they press <F1> in TRiLOGI the help files will be loaded from the “xx_Help” folder.

206. Chapter 11 11-3 IMPORTANT (16-bit variables comparison) When entering an integer constant using the hexadecimal prefix "&H", it is important to note the sign of the intend ed value and extend the signs to most significant bit of the 32 bit expression. E.g. to represent a decimal number "- 1234", the hexadecimal representation must be "&HFFFFFB2E" and not "&HFB2E". Assuming that a 16-bit variable DM[1] contains the number -1234 and a comparison statement is made to chec k if the number is -1234. The 32-bit hexadecimal representation of constant -1234 is &HFFFFFB2E. If you enter the constant as 16-bit representation "&HFB2E" as follow: IF DM[1] <> &HFB2E CALL 5 TBASIC translates the number "&HFB2E " into a 32-bit decimal number 64302, which when compared to the number "- 1234" contained in DM[1] will yield a "False" result which is an error. The following are the correct representation: a) IF DM[1] <> -1234 CALL 5 : ENDIF b) IF DM[1] <> &HFFFFFB2E" CALL 5: ENDIF 11.2.2 Integer variables: Variables are memory locations used for storing data for later use. All Integer variables used in TBASIC are GLOBAL variables - this means that all these variables are shared and accessible from every custom function. With i-TRiLOGI version 6.2 and above, you can now attach comments to any variable name of any length to make program easier to read. See section 5 (Integer Variable Comments) below for more details. Specific examples with each variable type are shown below. TBASIC supports the following integer variables: 1. 26 Integer variables A, B, C....Z whic h are 32-bit variables. Note that the variable name is a single character by default; however, as mentioned above, you can append a comment to the variable. EG: A_temperature, A_distance - both refer to the same variable A 2. A large, one-dimensional 16-bit integer array from DM[1] to DM[4000], where DM stands for Data Memory. A DM is addressed by its index enclosed between the two square brackets "[" and "]". e.g. DM[3], DM[A+B*5], where A and B are integer variables. A comment can also be

32. Chapter 3 3-4 1) Find out what your routers gatewa y address is (typically 192.168.1.1 or 192.168.0.1) and what static IP addresses are free to use with your PLC. NOTE: if the routers gateway address is “192.168.1.1”, the default PLC IP address (192.168.1.5) will most likely work unless it is already used by another device on the same network. If it is free to use, the next two steps can be skipped as the PLC will already be able to connect to the LAN. 2) Connect to the PLCs serial port from the PC with TRiLOGI and TLServer. 3) Edit the PLC network settings usin g the Ethernet & ADC Configuration tool from the “Controller” menu in TRiLOGI. Only the IP address is necessary to configure for basic connection to the LAN. Please refer to the Quick Connection guid e in appendix 1 to connect the PLC to your PC via serial port. Please refer to chapter 2 of the PLCs user manual for more detailed information on network configuration. Network Wiring You will likely already have a network av ailable that consists of an Internet modem that provides Internet to a wire d or wireless router, which has at least one PC connected to it. In this case, all that needs to be done is connect the PLC to the router with standard Ethernet cable. The final network configuration will likely resemble the below simple network diagram. If you are on a corporate network, then you will need to consult the IT administrator to get the PLC connected to the network.

44. Chapter 4: Using TLServer 4-1 4 USING THE TLSERVER – WEB SERVER FOR TRILOGI 4.1 Overview When you first start TLServer, the following window will appear. Refer to chapter 1.5 Run TRiLOGI and TLServer for instructions on starting TLServer. Traditionally, the TLServer program is used as the software gateway to connect the (now legacy) M-series PLCs to the corporate LAN or the In ternet so that they can be controlled and programmed by an i-TRiLOGI client from anywhere in the world. M-series PLCs did not have built-in TCP/IP network capability and therefore had to rely on the PC and TLServer software to provide the network connectivity. TLServer provides the TCP/IP interface to the network client and it then pass the data to/from the PLCs via their RS232 or RS485 serial ports only. On the newer Super PLCs such as the Na no-10, FMD or F-series PLCs, there is already a built-in Ethernet port which allows them to be connected to a router and hence directly accessible to/from t he Internet. TLServer is therefore not needed for normal Ethernet communication with the PLC. However, TLServer is still an important tool for i-TRiLOGI software to connect to the PLCs under the following circumstances: 1) A router connection is not readily available to the PLC. 2) The IP address and/or port number of the PLC's Ethernet port is unknown 3) The PLC' Ethernet setup parameter tabl e is corrupted, rendering the Ethernet port inaccessible. With TLServer, as long as there is an available serial port (RS232/RS485 or USB- RS232/RS485 adapter) on the PC, the i-TRiLOG I software will be able to connect to the PLC without using the PLC's Ethernet port at all. This allow i-TRiLOGI software to reset the PLC's Ethernet confi guration in case of corruption or lost configuration data.

69. Chapter 5 Chapter 5 Running The Internet TRiLOGI Client

87. Chapter 6 6-13 item #1 "SeqN:x". When prompted to select a sequencer choose "Sequencer 1" and another dialog box will open up for you to enter the specific step number for this sequencer. At this point, you shou ld enter the number "1" since we are using Step #1. 3. We have thus far been creating ladder circuits only by clicking on the ladder icons. A short-cut method of choosing elements to be created without using the mouse does exist. Observe the icon carefully and you will notice a small numeral at the lower right hand corner of each icon which correspond to the shortcut key. You may wish to try this short-cut for the remaining part of Circuit #3. Press the <7> key and the Output table will immediately pop up for selection of a coil. Pick "Out1" from the "Output" table and the "Out1" coil will be connected. 4. Circuits #4, 5 and 6 ar e very similar to Circuit #3 and you shouldn't have problem creating them. Complete these circuits and we are ready for some interesting simulation exercises. When yo u have created all the circuits, press <Enter> key or <ESC> key at the last blank circuit to end "Ladder Edit" mode. 5. Next, we want Seq1:4 contact to execute a "Custom Function" (the abbreviation is CusF). A custom func tion is one that you can create to perform very sophiscated control acti ons using the TBASIC language. The Custom function can contains multiple TBASIC statements that gives the PLC extremely powerful capabilities unma tched by many ladder-only type of PLCs. The Circuit we wish to create is as follow: 6. First, create the contact "Seq1:4" as pe r previous circuits. T hen left-click on the to connect to a Special Function coil. Select from the popup menu the item "E: Diff. Up Cust om Function" to create a "Differentiated Up" version of Custom Function (For a full explan ation of the meanin g of Differentiated Up", please refer to TBASIC Introducti on). The Custom function popup menu will appear for you to select the Custom Function number you wish to insert. Up to 256 Custom functions can be de fined and you can click on the first custom function, as follows:

130. Chapter 8 8-24 8.3.10.1 BASIC CONFIGURATION 1. IP Address One of the most important parameters that you must define here is the “IP Address” field (as shown above). By defaul t, every F-series PLC is shipped with the static IP address: “192.168.1.5”. You will need to assign the PLC’s with an IP address that is unique on your network an d yet is accessible from your PC. If you are on a company network, then you mu st consult your company’s system administrator to assign you a useable IP address. However, if your PC is connected to a sm all local area network, then most likely you will have a LAN IP address of 192. 168.XXX.YYY. For proper networking, you

131. Chapter 8 8-25 should set the PLC’s IP address to “192. 168.XXX.ZZZ”. i.e. The first three numbers should match each other. The fourth number (ZZZ) should be an IP address that is not used by any other devices on your network. Note that majority of small LANs are bu ilt using a network router that assigns dynamic IP addresses (called DHCP server) to the PC. You should enter the administrator page of the router and de fine the range of DHCP for use by the PCs and then you may assign the PLC with any IP address that is outside of the DHCP range. E.g. If you define the DHCP address range to be 192.168.1.100 to 192.168.1.150, then you may assign t he PLC with any IP address between 192.168.1.2 to 192.168.99 (Usually the router itself would have the IP address 192.168.1.1, and the address 192.168.1.255 is reserved so these two addresses are not available) and also between 192.168.151 to 192.168.1.254 (again making sure that 192.168.1.254 is not already used by your router). 2. GateWay IP Addr The Gateway IP address (as shown above) lets the F-series PLC communicate with other LAN segments or connect to the Internet. The gateway address is usually the local IP address of the rout er where the PLC is connected. For small local networks with no plan for connection to the Internet, the Gateway IP Address is not needed and can be set to 0.0.0.0. But if you plan to use the Fserver’s email capability then you must fill in the correct Gateway IP Address. Ask your system administrator if you have any question about this. 3. SMTP Server IP Address The SMTP (Simple Mail Transport Protocol ) Server field (as shown above) lets you define the IP address of the email se rver that the PLC can use to send out emails from user’s program (for F-series PLC users, please refer to Chapter 2.4.2 of the User Manual for more details on how to program the PLC to send emails). This is the same SMTP server that your normal email client software such as Thunderbird or MS Outlook uses to send out email. You can ask your Internet Service Provider (ISP) for the IP addre ss of their SMTP server. The ISP usually provides the SMTP server in domain na me form (such as “mail.sbcglobal.net”), but you should also be able to reques t the numerical IP address of the SMTP server from the ISP.

135. Chapter 8 8-29 selected, the i-TRiLOGI client or Java Applet can log-in to the FServer using whatever username and password since FServer will bypass the username and password authentication and allow the client to log in. 11. Access Level You can define the access level that the i- TRiLOGI client is permitted to operate under on the PLC. Three access levels are currently defined: 1 for Programmer, 2 for User and 3 for Guest. Please see the TL Server User Setup fo r the definition of the access levels. 12. Advanced Configuration The Advanced Configuration button lets you configure other more advanced (beyond the basic Ethernet configuration) , but less often used features of the PLC. This includes definition of the “Trusted IP” addresses as well as calibrations of the PLCs Analog I/Os and Real Time Clock (RTC).

152. Chapter 9 Chapter 9 Ladder Logic Language Reference

154. Chapter 9 9-2 the same job. Of course it makes little sens e to use a PLC if that is all you want to do. We will see how a PLC can simplify wiring shortly. Note: The contact "Switch" shown in the abov e diagram is termed a Normally-open (N.O.) contact. Now, let's say if there are 3 switches that must work together to control the lamp. A Master switch must be ON, and one of the two control switches "controlsw1" and "controlsw2" must be ON while the other must be OFF in order to turn ON the lamp (think of three-way switches in your house and you will get the idea). We can wire all 3 switches to 3 inputs of the PLC and the lamp to the output of the PLC. We can write the following ladder program to perform this task: A contact with a "/" across its body is a Normally-Closed (N.C.) contact. What it means is that the ladder program is using the "inverse" of the logic state of the input to interpret the diagram. Hence in the above ladder diagram, if "M aster" and "controlSW1" are turned ON but "controlSW2" is turned OFF, the lamp will be turned ON since the inverse logic state of an OFF state "controlSW2" is tr ue. Think of an imaginary current flowing through the "Master" contact, then throug h the "controlSW1" and finally through the normally-closed "controlSW2" contact to turn ON the lamp. On the other hand, if "controlSW1" is OFF but "controlSW2" is ON, the Lamp is also turned ON because the current could fl ow via "Master" and then through the lower parallel branch via N.C. "controlSW1" and the N.O. "controlSW2". Note: As you can see, although the switch "controlSW1" is connected to only 1 physical input to the PLC, but it appe ars twice in the ladder diagram. If you actually try to connect physical wires to implement the above circuits, both "controlSW1" and "controlSW2" will have to be of multiple poles type. But if you use a PLC, then these two switches only need to be of single-pole type since there is only one physical connection whic h is to the input terminal of the PLC. But in the ladder diagram the same cont act may appear as many times as you wish as if it has unlimited number of poles.

221. Chapter 12 12-5 Comments : CRC16 for DM[5], DM[6]... ..DM[12] will be assigned to DM[100] CRC16 for RELAY[2], RELAY[3], RELAY[4], RELAY[5] will be assigned to X. 12.10 DELAY n Purpose : To provide a time delay of n millisecond to the process. Example : DELAY 100 Comments : Provide a 100 ms (0.1s) delay to the current custom function. It is important to note that this is a “brute force” delay method and only to be used with caution. When a DELAY function is executed the CPU wa its at the statement until the period specified by the “delay” is over. This means that all the remaining ladder programs and other custom functions will stop responding to changing input conditions, only system services (serial input, countdown timers and host link commands etc) as well as interrupt driven CusFns will work during the period of delay. This may not be desirable if the rest of the process must respond to fast changing inputs. For delays longer than 0.1s a much better way is to invoke the regular PLC timer and use the timer contact to trigger another custom function at the end of the delay. Note that for Nano-10, FMD Series, and F-series PLCs, the minimum delay is 1ms and the re solution is 1ms, whereas for the Legacy T100MD+ and T100MX+, the minimum delay provided by this function is 10ms, and the resolution of the time delay is 10ms. This means that if you execute DELAY 155 the actual delay will be rounded to 160ms, whereas for DELAY 154 the actual delay will be 150ms. 12.11 EXIT Purpose : To exit from a WHILE.. ENDWHILE or FOR....NEXT loop

223. Chapter 12 12-7 incremented by the amount specified by STEP. If STEP is not specified, the increment is assumed to be 1. A check is performed to see if the value of the counter is greater than the final value y if ST EP is positive (or smaller than the y if STEP is negative). If it is not greater, the program branches back to the statement after the FOR statement, and the process is repeated. If it is greate r, execution continues with the statement following the NEXT statement. This is called a FOR-NEXT loop. A run-time error will result if STEP is evaluated to be 0. Examples : FOR I=1 TO 10 FOR J = 100 to 1 STEP -10 DM[I] = DM[J] NEXT NEXT Comments : FOR-NEXT loops may be neste d; i.e. a FOR-NEXT loop may be placed within the context of another FOR-NEXT loop. When loops are nested, each loop mu st have a unique variable name as its counter. The NEXT statement for the inside loop must appear before that for the outside loop. Each Loop must have a separate NEXT statement to mark the end of the loop. See Also : WHILE..ENDWHILE , CONTINUE 12.13 GET_IPAddr dmindex Purpose : To return the IP address of this PLC's built-in Ethernet port and store each '.' separated valued and the port number in DM[dmindex] to DM[dmindex+4]. Comments : To return the IP address of a PLC's Ethernet port into the variables DM[100] to DM[104] (e.g. to display on a HMI panel), you can invoke a function that runs GET_IPAddr. Example : GET_IPAddr 100 ‘ Return the IP address and port

230. Chapter 12 12-14 Purpose : To define PLC Timer #1 to #n as “High Speed Timers” (HST). A HST counts down every 0.01s inst ead of every 0.1s for normal timer, and their other properties are identical to normal timer. Those Timers whose number are above n are not affected and remain ordinary timers. 12.24 I2C_READ i2cslave, dmstart, count Purpose : Special command to execute a I2C_READ out of the PLC's I2C port (requires I2C-FRTC module to be installed). Comments : The CPU will send a I2C START bit, followed by the slave address byte (i2cslave) with "R/W" bit set to high, and then send out the number of clock pu lses required to read count number of data bytes from t he the slave. The data bytes received from the slave will be stored in the memory location DM[dmstart] to DM[dmstart+count-1]. After receiving all the required data bytes the CPU will send the I2C STOP bit to the slave to end the communication. i.e. there is no need execute the I2C_STOP command after an I2C_READ command. Parameters : i2cslave = The 7-bit slave address that the CPU is reading from. dmstart = The starting index of the DM[ ] that is to receive the first data count = number of data bytes to read from the slave. Example : I2C_READ &H0C,21,2 ' read 2 bytes into DM[21] and DM[22] After sending the START bit, the CPU will write the 7-bit slave address &H60 (=110 0000 binary) and a R/W bit set to 1, followed by 16 clock pulses to read 2 bytes of data and store into DM[21] and DM[22], and then the CPU will generate the STOP bit. See Also : I2C_WRITE , I2C_STOP Note:

244. Chapter 12 12-28 12.42 PIDdef ch, lmt, P, I, D, Purpose: To set up the parameters for a Proportional, Integral and Derivative (PID) Controller function. The function PIDcompute( ) will make use of the parameters defined here for the corresponding channel #ch. Ch = channel number (1-16) Lmt = Maximum (saturation) limit for the computed result. P = Proportional Gain (KP) I = Integral Gain (KI ) D = Differential Gain (KD) Transfer Function of a PID Controller are defined as follow: All four parameters: lmt, P, I & D can be either 16 or 32-bit integer constants or integer va riables. For the lmt term, the computed controller output value by the PIDcompute( ) function is not allowed beyond the + lmt value (i.e. lmt represents the saturation point of the computed controller output). PIDcompu te( ) function implements "Integrator anti-windup" featur e, which will avoid integrating the error signal when output is already saturated . Important: When this statement is run, the integral and differential terms of channel ch is set to zero. Hence PIDdef should be run only once during initialization and not repeatedly executed. Otherwise the PIDcompute( ) fu nction will not run properly because of the loss of integral and differential data. See Also : PIDcompute( )

246. Chapter 12 12-30 character in the argument list. A PRINT statement that ends with a semi-colon “;", will not send the CR character. If you have a long string to send than you can use ";" to break the whole command into several lines, with each line ending with a ";" except the last lines. Examples : PRINT #2 "The value of A+B = ";A+B; PRINT #2 "Units" Comments : IF A=5 and B=100, the string "The value of A+B = 105 Units" and a CR character will be sent out via Comm. port #2. In TRiLOGI simulation mode, the ASC II string will be displayed on a pop-up window to simulate PRINT action. See Also : INPUT$( ) 12.45 PULSEFREQUENCY(ch) PULSEPERIOD(ch) PULSEWIDTH(ch) Purpose : Return in Hz the frequency of the last input pulse; Return in microseconds the width or period of the input pulses arriving at channel #ch of the pulse-measurement pin. Parameters : ch = channel # (1-8) Comments : The pulse-measurement channel #ch must have been enabled by the PMON statement already. However, if you need to use the HSC and the Pulse Measurement on the same channel, then you don’t need to execute both the HSCDEF and PMON, so you should only need to execute the HSCDEF. The HSCDEF function wi ll automatically configure the Pulse Measurement function so it is not necessary to use the PMON function (in fact If yo u run the PMON command after HSCDEF, it actually disables the HSC). However, if you use only the PMON function, it would not enable the HSC function. If the pulses stop coming in, then PULSEFREQUENCY will return a zero while the other two functions will saturate at a certain

247. Chapter 12 12-31 maximum value (for Nano-10, FMD series, and F-series PLCs it is equivalent to about 3.28 seconds) The SETSYSTEM 20 command can be used to switch the resolution between 1us (default) and 0.1us. Example : A = PULSEWIDTH(1) See Also : PMON / PMOFF 12.46 READMODBUS (ch, ID, addr) Purpose : Use the MODBUS ASCII or RT U protocol to automatically query a MODBUS ASCII or RTU slave de vice and obtain the desired 16-bit register data. The commu nication baud rate is the default baud rate of that Comm port unless it has been changed by the SETBAUD command. Parameters : ch - PLC Comm port number (1 to 3 using Modbus ASCII or 11to 13 using Modbus RTU). ID - device ID of the MODBUS device (1 to 255) addr - zero-offset address of the holding register in the MODBUS device. Example : relay [3] = READMODBUS(3, 5, 101) Comments : The relay will contain the 16-bit data obtained from the MODBUS device with ID = 05 and from register offset address 101 (in MODBUS term this refer to the #40102 holding register) . Reading it into the relay[ ] channel allows bit level manipulation by ladder logic. It can of course also be read into any data memory. This command automatically checks the response string received from the slave device for the correct LRC and the slave address. The status of th e operation can be checked by the user program by testing the STATUS(2) function, which will return a ‘0’ if there is any erro r or if the slave device is not present.

262. Chapter 12 12-46 Purpose : To set channel #n of t he PLC's Digital-to-Analog Converter (DAC) with the 16-bit integer resu lt of the expression x. n must range between 1 and 16. Once set, the DAC channel will latch the set value until the next SETDAC statement on the same channel is executed. Examples : SETDAC 5,A+B*16 Comments : DAC channel #5 will be set with the value of A+B*16. A run- time error will result if n is less than 1 or is greater than 16. The actual number of DAC channel s depends on the PLC model in use. 12.65 SETDimmer ch, value Note : Applicable only to F-series PLCs Purpose : To set channel #channel of the F-series PLC's Light Dimmer Control outputs to fire a trigger pulse to opto-isolated TRIAC (or Solid State Relay). Comments : The trigger pulse is fired after a time delay specified by the value parameter (each unit is equal to about 53 microseconds) and it is measur ed with respect to the zero crossing that occur at every half cycle of AC voltage. Parameters : ch = Channel. Range = 1 to 12 (which maps to FPLC outputs #5 to 16) value = Trigger Pulse Time Delay. For 50Hz AC signal, range =1 to 188 For 60Hz AC signal, range =1 to 156 Note : when value = 1 the output is fully ON. When value is near is maximum value the output is fu lly OFF. Do not set value to larger than the maximum for each particular AC frequency. Example : SETDIMMER 1,78 The PLC light dimmer output channel 1 (which corresponds to digital output #5 of F-series PL C) will send a short trigger pulse

265. Chapter 12 12-49 When using TRiLOGI the software will automatically prompt you to enter the password string if it encounters a PLC which has been password-locked. Note that the password is case sensitive. Password locked PLC cannot be accessed by older version of TRiLOGI. Comments : This feature is mainly used to protect an unattended PLC which is linked to an auto-answer modem. Without password protection anybody can dial in with a TLServer or TL41.exe and have full control of the PLC, which may be a serious security problem. Within the PLC software you may also use a timer to periodically re-arm the PLC with this command for maximum protection. You can also use different passwords for different time of the day or a set of rotating passwords to provide greater security. If you are linking the PLC to the internest via i-TRiLOGI , you will notice that the TLServer already provides username/password authenticat ion. However, the password here works independent of the access provided via TLServer, hence this command can still be used to provide an additional layer of security against unauthorized access to the PLC. 12.70 SETPROTOCOL ch, mode Purpose: A Nano-10, FMD series, and F-series PLC (as well as the legacy T100M series) automatically senses the type of communication protocols sent to it and responds accordingly. You may however fix the protocol type so that it does need to check the protoc ol type before responding. This command also allows the PLC to be defined as “No Protocol” so that it will not automatically re spond to data that it receives which appears like one of the supported protocols. This may be important in some applications in which the PLC serial port is used purely to receive incoming data via INCOMM and INPUT$ and you do not want it to respond to some data that appears to it as a valid communication protocols This is also useful for implementing user’s own communication protocol without worrying about conflict with the existing protocols.

285. Chapter 12 12-69 Comments : When STEPMOVE command is first executed, the internal relay #r will be cleared before the fi rst pulse is sent. After the completion of the movement (i .e. when all the pulses have already been sent), the relay #r will be set. Count is a 32-bit integer number which allows you to program the stepper motor to move from -2 31 to +2 31 .(i.e. about ± 2 x 10 9 ) steps. Count can also be an integer variable A-Z. However, if you use a 16-bit vari able such as DM[n] for count then the range of movement can only be between 1 to 32,767. Pulse generation can be interrupted by issuing a STEPSTOP command in another CusFn, which may occur in cases when the hardware hits a limit-switch and must stop the motor immediately. Important: When a stepper channel is already activated (i.e. mid-way through its pulse generation) re peat execution of STEPMOVE command on the same channel will be ignored by the PLC. Re-execution of the STEPMOVE command on this channel can only take effect after the channel’s pulsing operation has been completed by itself or aborted by the STEPSTOP command. When in TRiLOGI simula tion mode, execution of the STEPMOVE command will bring up a pop-up window that displays all the parameters of the motion path.

315. Appendix 2 A2-9 The timer #1’s Present Value (P.V) register is loaded with this number, which will start the timer countdown. In the next logic rung, the timer coil connected to the latched “OUT1” is necessary to prevent the timer from resetting itself. But It will not overwrite the PV with its own Set Value (SV), which will not be used at all in this case. This is because the previo us ladder program has already started the timer with a value determined by the position of the potentiometer “knob”. A2.2.4 Motion Control of Stepper Motor The ‘Super’ PLC can generate pulses to feed to stepper motor driver. The maximum speed, acceleration , deceleration and total number of pulses to generate are definable using TBASIC. Both absolute positioning commands and relative move commands are supported. Assignment: 1. A “DEFHOME” input define the current location as home position. 2. Press the “START” input to begin Inde xing the stepper motor to position at 1500, -2000, 4500 and 9000 steps with resp ect to the HOME position. Pause for 1 seconds at each position. Return to home at the end of the cycle. 3. Maximum speed = 5000 pps, Acceleration=100 steps to full speed.

21. Chapter 1 I-TRiLOGI Setup Guide 1-8 1.5 Run TRiLOGI and TLServer All i-TRiLOGI Version 6.x files will be installed in the following default folder: "C:\TRiLOGI\TL6" You normally would not need to go directly to this folder to run TRiLOGI or TLServer. This is because during installation of i-TRiLOGI, a program Group folder "i-TRiLOGI 6.xx" will be created in the St art Menu to provide short cuts to the TLServer program, the i-TRiLOGI applic ation and the TL6 Applet starter, as illustrated in the following picture. In the example screenshot above, the TRiLOGI programming environment can be started by selecting “i-T RiLOGI Version 6.4” from the option list. TLServer can be started by selecting “TLServer Version 3.1” Note: A short cut for TLServer is also crea ted on the “Quick Launch” toolbar. For Windows XP user, you may have to right click on the tool bar area

112. Chapter 8 8-6 of interfacing to other equipment, but wi thout revealing the core content of the PLC program to the end user. Beside s being able to protect the OEM's intellectual property, it will also help to prevent the end users from mistakenly modifying the core program which can lead to disastrous result. 8.1.7 Write Compiled Code to Disk This new feature is added since i-TRiLOGI version 5.32. You can now write the compiled program code to a disk file so that you can send the compiled code (with a ".CO5" extension) to your end customer to upload to the PLC using a standalone "TL5 Uploader" program. This allows you to protect your source program file content, while gi ving the end users of your equipment the ability to upgrade the PLC program. The end users DO NOT need to install the i-TRiLOGI or the Java JRE in order to use the TL5 Uplo ader program. so that makes it more flexible for you to distribute self-upgrade for the end users. The TL5 Uploader program can be obtained by emailing to "sales@tri-plc.com" and installed by first unzipping the "Insta ll TL5 Uploader.zip" file found in your i- TRiLOGI Version 6.x CD-ROM or and then run the "Setup.exe" program. Please note that the "TL5 Uploader" is a copy righted program and Triangle Research International is the copyright owner of th is program. However, Triangle Research International authorize the licensed users of the i-TRiLOGI version 5.xx software to freely distribute the "Install TL5 Uploader .zip" program to their end users at no charge. Note: 1. Although i-TRiLOGI version 6.x suppo rts Unicode for its user-interface, the compiled code produced by TL6 is iden tical to that of TL5 and therefore the compiled file is still saved in ASCII format. To maintain backward compatibility the "Write Compiled Code to Disk" function still produces ".CO5" file that can be uploaded using the TL5 Uploader" program. 2. Beginning from i-TRiLOGI version 6.41, you can also use the i-TRiLOGI software to transfer the .CO5 file to the PLC. This allows licensed i-TRiLOGI users to exchange compiled .CO5 file without revealing the source code. 8.1.8 Print You may use all the printing resources supported by your O/S to print a selectable range of the ladder diagram, t he I/O Tables or the custom functions. When executed the following "Print Control Panel" will appear:

119. Chapter 8 8-13 normally identified by their label name s. However, you can also choose to display an optional small literal to indicate the I/O types and physical I/O number, which is now linked to the I/O labelname. e.g. i1=input 1, o12=output 12, r25= relay 25, t1= timer 1 and c5=counter 5. When i-TRiLOGI first starts, the display is enabled but you have the opti on of turning it off if you find it distracting. 8.2.10 Edit Custom Function <F7> Opens up the Custom Function Editor window for you to enter the TBASIC program. You will be required to select the custom function number or a label name from the CusFn table (which is part of the I/O Table) . Each i-TRiLOGI file can contain a maximum of 256 custom fu nctions. At any one time only one custom function will be opened for ed iting. The custom fu nction number and the required label name will be displaye d on the Title of the Custom Function editor window: NOTE: This is a new and improved custom function editor. For a full description of its features, see the TBasic Introduction page and go to the 2. Custom Function Editor section. 8.2.11 Clear Custom Functions This command allows you to select a ra nge of custom functions whose content you want completely cleared. You will be prompted to select the range of custom functions to erase. Note that this action is not undoable.

34. Chapter 3 3-6 2) Next you need to configure the seri al port settings by clicking on Serial Port Setup , and the above-right window will open. The default serial port settings are as follows: Baud Rate : 38400 bps Data Bits : 8 Stop Bits : 1 Parity : None (N) Time Out : 500ms These settings match the default com settings for all ‘Super’ PLC serial ports, so they don’t need to be changed unless they have been specifically modified by a PLC program transferred to the PLC after purchase. 3) The only setting that needs to be checked and possibly modified is the Port Name . This is the com port that the PC uses to connect to the PLC. Select the COM port that the USB adapte r is installed on (or the built-in RS232 port if your PC has one) from t he drop-down menu. Note that the USB adapter would need to be installed prop erly before starting TLServer or it wouldn’t be available from the drop-down list. 4) You can test the COM setup by entering a Host Link command in the “Command String” field. The following example is a good basic command to

72. Chapter 5 5-3 3. Next, check the TLServer front panel for its IP Address. If you are running TLServer on a PC without network co nnection it will probably show: IP Address = 127.0.0.1:9080. If you have an Internet connection before you start up TLServer, then you will see the Internet IP address of your PC. If your PC has both a local area network connection as well as a direct Internet connection, you will see two IP addresses being reported. (Although localhost address 127.0.0.1 may not be reported but it is always there as long as both the Client and the Server reside on the same computer. Always use the localhost IP address 127.0.0.1 if both the Client and the TLServer are running on the same computer.) 4. Now, simply key in the IP Address, including the port number in your browser's "Address" (for IE5) or "URL" (for Netscape) text entry area. For localhost connection, enter: http://127.0.0.1:9080 5. The browser will now issue a HTTP request to the TLServer. Since no filename has been specified, the default file in the web-server root directory "index.html" is loaded. This HT ML file is written in Javascript to provide some other options. To start the TRiLOGI as an applet, select the appropriate option and the TL6Applet.jar file will be loaded from the TLServer into your browser for execution.

74. Chapter 6 Chapter 6 Ladder Logic Programming Tutorial

77. Chapter 6 6-3 4. Press <Enter> key again and the highlight bar will be moved to Input #2. 5. Without using the mouse button, simply start typing the name "Stop" at Input #2. The text field will be automatically opened up at Input #2 for entry. Press <Enter> after typing in the name for "Stop" input. 6. Complete entry of the other two input label names "Manual" and "Step" as above. Note that i-TRiLOGI Version 6. 2 and up allows I/O label names of up to 16 characters. However, if you wish to keep compatibility with Version 5.x to 6.1x, you should use no more than 10 characters to define the I/O names. Also, white spaces between names are not acceptable and will be automatically converted to the underscore character ( '_' ). e.g. If you enter the name: "F series PL C" for an I/O, it will be accepted as "F_series_P". 7. After entering label names for Inputs #1 to #4, move to the "Output" table by pressing the right cursor key or by clicking on the right arrow button. Enter all the output and relay label na mes in their respective I/O tables. We will discuss the "Timer" table in the next step. IMPORTANT 1. You can shift the Items in the I/O ta ble up or down or insert a new label between two adjacent, pre-defined labe ls. Simply press the <Ins> key or Right-Click the mouse button to pop up the "Shift I/O" menu, which allows you to shift the selected I/O. However, please note that if you shift the I/O down, the last entry in the I/O table (e.g. Input #256) will be lost. 2. In i-Trilogi 6.2 and up, shifting of Custom Function Label names will now shift the function content along with the la bel name. (In previous versions of i- Trilogi, shifting of the I/O label would not shift the function content, therefore making it untenable to use I/O label shift to reorganize custom functions. Warnings are provided if such an action were to result in overwriting of an existing custom function. 3. i-TRiLOGI Version 6.2 and up allows I/O label names of up to 16 characters. However, if you wish to keep compatibility with Version 5.x to 6.1x, you should use no more than 10 characters to define the I/O names.

91. Chapter 6 6-17 3. The label names for the inputs, output s, relays, timers and counters defined earlier in the I/O tables au tomatically appear in thei r respective columns. To the left of each label name column is an "LED" lamp column which indicates the ON/OFF state of respective I/O. A red color lamp represents the ON state of an I/O, whereas a dark grey color lamp represents an OFF state. The I/O number is indicated in the middle of the lamp. The simulator requires the use of the mous e to work properly, so it is important to remember the mouse button actions as follows: Left Mouse Button Turn ON the I/O when pressed. Turn OFF when button is released. Right Mouse Button Toggle the I/O when pressed once. (i.e. OFF becomes ON and ON become OFF) 4. Our ladder program requires us to "p ush" the "Start" button momentarily. You can simulate this action by moving th e mouse pointer to the "Start" label (or the LED lamp) and press the LEFT mo use button once and then release the button. The action starts! 5. At this time, notice that the relay "R UN" is latched ON an d the timer "Duration" begins to count down from the valu e of 1000 every 0.1sec, and the Output #1-#8 are turning ON/OFF sequentially in a "running light" pattern. Sequencer "Seq1" in the "Ctr/Seq" column begins to count upward from 1 to 3 and then overflows to 0 and repeats continuously . For each step of the Sequencer, the corresponding Output will be turned ON. Our demo program will show a running light pattern starting from Outputs 1 & 8, then 2 & 7, 3 & 6 and 4 & 5 and then back to 1 & 8, 2 & 7..... 6. Now you should verify that the logi c works as intended by observing the ladder diagram. You should notice that the "Run" labels in all circuits are highlighted as shown below:

123. Chapter 8 8-17 You can find out the PLC's firmware ve rsion number, the maximum of input, outputs, relays, timers and counters supported on this PLC as well as the total amount of program memory available. The same info will be displayed when you try to transfer a program to the PLC. 8.3.8 Set PLC's Real Time Clock The PLC's real time clock (RTC, which in cludes both date and time) can be set quickly using this command. When you ex ecute this command, a dialog box which contains the year, month, day, hour, min, sec and day of week are displayed for you to enter the value. The dialog box is initially filled with value taken from the client's computer's own calendar and clock. You can change any of the field to the desired values and then click on the "Set PLC's Clock" button: The dialog box will be closed after the i- TRiLOGI has transferred all the data to the PLC. You should use on-line monitoring to verify that the data has indeed been properly written into the PLC. Note that the "Year" field is restrict ed to only between 1996 and 2096, "Month" is between 1 and 12, "Day" is between 1 and 31, "Hour" is between 0 and 23, "Min" and "Sec" are between 0 and 59. If yo u enter an illegal value i-TRiLOGI will beep and the cursor will be put at the o ffending text field. Correct the mistake and then click on the "Set PLC's Clock" bu tton again to transfer the values to the PLC. 8.3.9 EEPROM Manager This command allows you to read/write the EEPROM data content from and to a Nano-10, FMD series or F-series PLC (a s well as the legacy M-series PLC with

126. Chapter 8 8-20 Click on this button to write both the integer and string EEP buffer contents to the PLC’s EEPROM. i-TRiLOGI will prompt yo u to confirm the write action and it will also prompt you to login to a TLServer if it is not already connected to one. You can click on one of these two buttons to read a range of data EEPROM as 16-bit integer or as an ASCII string into their respective EEP Buffer. The program will attempt to login to a TL Server if it is not already connected. It will check the maximum EEPROM addresses available on the target PLC and then prompt you to enter the range of integer data yo u wish to read (up to the maximum available): The data read from the PLC are stored into the EEP buffer in comma-delimited format as described above. Integer EE PROM data can also be captured in hexadecimal format if you check the check box. You can edit or append to the captured data in the buffer and then write them back to the data EEPROM area or save as a hard disk file. You can save both the Integer and String EEP Buffers content to a single text file with the default extension “.csv”. The data are stored in comma-delimited format described above with Integer data being save first, then followed by the string data. The comma-delimited format makes it very easy for a spreadsheet program such as MS-Excel to import t he data into the spreadsheet for further processing. You can also use MS-Excel to generate data that are to be written to the EEPROM and then save the file as “CSV” file, which can then be imported by EEPROM Manager using the “Load from File into Buffer” button. EEPROM Manager Applicatons

145. Chapter 8 8-39 the "Measured DAC", write them into t he PLC and then reboot it to complete the calibration. 3. Automating Analog Output Calibration The procedure described in th e last section may be a little bit tedious to work with since it involves several manual steps and require measuring the analog output readings and convert them into the 0-4096 range. It however illustrates the principle used by the calibration routine. In order to automate the calibration of the analog outputs, an additional button is included to assist with the task. When you click on this button, i-TRiLOGI will perform the following tasks: 1) It clears all the old analog output calibration parameters for any analog output channel that has a non-blank entry into the SETDAC field. 2) It reboots the PLC so that the anal og output from the PLC will be freed from any old calibration data. 3) It sets the corresponding analog output channel using the data entered into the "SETDAC" field. 4) It waits for one second and then read the DM[1] to DM[4] data from the PLC and store into the "Measured DAC" fields for DAC #1 to #4. Therefore, if your PLC's analog inputs are already calibrated previously, you can make use of your calibrated Analog inputs to measure your uncalibrated analog outputs and store the measured readings into DM[1] to DM[4] to be used by your calibration program! What you do is to connect the PLC's DAC #1 to its own ADC #1, DAC #2 to ADC #2 etc, and then write a PLC program to read the ADC data, take an average readings to even out white noise, then wr ite the average readings into DM[1] to DM[4]. The button can then retrieve the measured DAC readings from the DM[1] and DM[2 ] in a single step to perform the calibration. Alternatively, if you have a precision me asuring instrument that is capable of talking to your PLC (e.g. another PLC or an instrument that can communicate with the PLC via Modbus protocol), then the precision instrument can measure the DAC output of the PLC and write the measured readings into the DM[1] to DM[4] of the PLC, which can also be used by the button to read the measured readings easily.

146. Chapter 8 8-40 Once the reading has been obtained, just click on the button to complete the calibration. We have therefore reduced the analog ou tput calibration to a simple two-step process which can be easily handled by any production operator during production of an OEM equipment. 7. Communicating with the PLC This program communicates with the PLC vi a the same user interface as all other communication functions under the "Con troller" menu. This means that the calibration tool will be communicating with the PLC using the TC P/IP protocol. If the PLC has a built-in Ethernet port then it should be connected to an Ethernet router or switch with a preconfigured private static IP address. If the PC is also on the same network then you simply login to the PLC server using the private IP address of the PLC. However, if you do not know or have lost the IP address of the PLC, t hen it is still possible to calibrate the PLC's by connec ting the serial ports on the PLC to the PC. In this case, you will need to ru n the TLServer on your PC and configure the PC's serial port to work with the PLC' s serial port. The configuration tool will connect to the PLC indirectly via the TLServer software. Click here for more details about TLServer. If your i-TRiLOGI is not yet connected to a TLServer software or directly to the PLC built-in hostlink command server (known as F-Server in the Nano, FMD or F-series PLCs), then when you try to calibrat e the PLC you will see the login popup windows as follow:

164. Chapter 9 9-12 9.3.4 Clear Relay Function [Clear] To de-energize a program element th at has been latched by the [Latch] function, it is necessary to use [Clear] function. On selecting [Clear], choose the output or relay to be de-energized. When the execution condition for that circuit is ON, the designated output or relay will be reset. In the ladder diagram, the program element label name will be shown above the [Clear] symbol. If the execution condition for [Latch] an d [Clear] functions are both ON at the same time, then the effect of the de signated bit depends on the relative locations of these two functions. Reme mber that an output or relay bit energized by [Latch] will remain ON until it is turned OFF by [Clear]. It is recommended that [Clear] circuit be placed just after the [Latch] circuit for the same output or relay controlled by these two functions. This ensures that [Clear] function has higher priority over [Lat ch] function, which is normally so in hardware latch-relay or other industrial PLCs. 9.3.5 Interlock [ILock] The "Interlock" [ILock] and "Interlock Off" [ILoff] functions work together to control an entire section of ladder circuits. If the execution condition of an [ILock] function is ON, the program will be ex ecuted as normal. If the execution condition of [ILock] is OFF, the progra m elements between the [ILock] and [ILoff] will behave as follow: a) all output coils are turned OFF. b) all timers are reset to inactive. c) all counters retain their present values. d) Latched relays by [Latch] function are not affected. e) [dDIFU] and [dDIFD] functions are not executed. f) all other functions are not executed. An Interlock section is equivalent to a master control relay controlling a number of sub-branches as follow:

189. Chapter 10 10-17 3. Likewise, any changes to the OUTPUT[n ] variable using the SETBIT or CLRBIT statement will not be transferred to the physical outputs until the end of the current ladder logic scan. Hence do not wait for an event to happen immediately after executing a SETBIT or CLRBIT statement on an OUTPUT[n] because nothing will happen to the phys ical output until the current ladder logic scan is completed. 4. If you want to force the output to change immediately you will need to execute the REFRESH statement. Consid eration must be given to how such an act may affect the other parts of the ladder program since not the entire ladder program has been executed. 5. Like all ladder circuits, the relative po sition of the circuit which triggers the CusFn may affect the way the program work s. It is important to consider this fact carefully when writing your ladde r program and TBASIC CusFns. Always remember that the CPU executes the ladder logic and CusFn sequentially, even though the equivalent circuits in hard-wired relay may seem to suggest that the different rungs of ladder circuits were to work simultaneously. 6. In line with the typical Ladder Logic programming rules, a CusFn may appear only once within the ladder diagram, re gardless of whether it appears in the normal or differentiated form. A compilation error will occur if a CusFn appears in more than one circuit. 7. However, a CusFn may be "CALLed" as a subroutine by any other CusFn and there is no restriction placed on the number of repeated CALL of a CusFn by more than one CusFn. A CusFn may also modify the logic states of an I/O element or the value of internal timers and counters using its powerful TBASIC commands (such as SetBit, ClrBit). Th e compiler however will not alarm the user that a CusFn may inadvertently al ter the logic state of an I/O already controlled by some other ladder circuit. This power and flexibility offered by t he TBASIC-based custom functions must therefore be handled with greater care by the programmer. It is important to prevent conflicting output conditions due to an I/O being controlled or modified at more than one place within a logic scan . The net result is that the logic state of the I/O appears to be in different states at different parts of the ladder circuit. This could lead to bizarre outcomes that may be difficult to trace and debug. 10.4.3 Interrupt Service CusFn A CusFn may also serve as an "Interrupt Service Routine" which is executed asynchronously from the normal ladder logic execution. An interrupt-driven

237. Chapter 12 12-21 12.33 LET Purpose : To assign the value of an expression to a variable Syntax : [LET] variable = expression Examples : LET D = 11 A$ = "Welcome to TBASIC" Comments : LET statement is optional: i. e. the equal sign is sufficient when assigning an expression to a va riable name. The variable type on both sides of the equal side must be the same. i.e. string variable may not be assigned to a numeric expression and vice-versa. Important : a) When assigning a 16-b it variable to a 32-bit integer, only the lower 16 bits of the 32-bit integer will be assigned. Hence the programmer must take special care if the 32-bit number is out of the range of a 16-bit number (which is between -32768 to 32767). b) If a negative 16-bit numb er is assigned to 32-bit integer variable, then the sign bit will be extended to 32 bits. e.g. DM[1] = -123. A = DM[1] The 16-bit hexadecimal value of -123 is &HFF85, but A will be assigned the hexadecimal va lue &HFFFFFF85. Their decimal representation are however the same. 12.34 LOAD_EEP(addr) LOAD_EEP8 (addr8) LOAD_EEP16 (addr16) LOAD_EEP32 (addr32) Note : LOAD_EEP8, LOAD_EEP16, and LOAD_EEP32 are only available on PLCs with firm ware >= r78. LOAD_EEP is equivalent to LOAD_EEP16 and is available on all firmware versions.

255. Chapter 12 12-39 However, when the addresses grow larger up to a certain point, the integer and string data space will cross path and overwrite each other’s space. It is therefore the programmer’s responsibility to check that this does not happen. Here is how: Assume the total data space for integer data = N words (16 bit). Total number of data space = 2N bytes => Maximum number of string data space = 2N/40 (rounded down). To determine the upper limit of one type of storage, you have to first decide how much space you want to allocate to the other type. E.g. 1 : N = 1700, and you want us e the first 510 location for integer data, that means the maximu m number of string space available = (1700–500)*2/40 = 59. E.g. 2 : N = 7700, and you want to store 200 strings. The maximum number of integer space av ailable = (7700*2 – 200*40)/2 = 3700. Example : save_EEP$ A$,3 The content of A$ will be stored at string space #3 of data EEPROM. See Also : LOAD_EEP$( ) 12.56 SET_DNS dmindex Purpose : To set the DNS address of th is PLC's built-in Ethernet port using the parameters stored in DM[dmindex] to DM[dmindex+3]. Comments : To change the DNS address of a PLC's Ethernet port, you can load the new DNS address into the variables DM[100] to DM[103] (e.g. from a HMI panel ) and then invoke a function that runs SET_DNS 100 to write the new DNS address into the PLC.

107. Chapter 8 8-1 8 TRILOGI MAIN MENU REFERENCE Both TRiLOGI application and applet pr ograms have nearly identical look and feel (as shown below), with the exception that the applet can’ t save to or load from local drive. The main body of the program window is for displaying and editing your ladder logic program. A ladder logic program is made up of many ladder “rungs”. In TRiLOGI we call each ladde r rung a “circuit” with an associated “circuit number”. The currently selected circuit is marked by a little red triangle pointed to the circuit’s intersection with the left vertical line (a.k.a. the “power rail” in ladder logic terminology) The circuit number of the selected circui t is displayed on a button located just above the top left corner of the ladder ed itor window. If you happen to click on this button, a dialog box will popup that prompts you to enter the circuit number you wish to go to and the editor will br ing you there immediately. The five blue buttons next to the Circuit # butto n are called “Bookmarks” and their usage has been covered in details in Chapter 6. 8.1 File Menu The File menu provides commands for the opening/saving of i-TR iLOGI files either on the local harddisk or on the TLServer's storage space.

30. Chapter 3 3-2 3.1.1 Serial Port All TRi ‘Super’ PLCs have at least one RS485 port and all but the Nano-10 have a RS232 port. Either of these ports can be used to connect a PC to the PLC for programming or monitoring. RS232 TRi ‘Super’ PLCs with a DB9 serial port (9-pin connector) can interface via RS232 directly to a PC if it has the same type of port or indirectly through a USB port. Most modern PCs now only have USB seri al ports, so this would be the only option. For USB connection, you will need a USB to RS232 adapter that plugs into the USB port of a PC and the DB9 serial port of the PLC. Typically a straight through DB9 cable will need to be added to the adapter to extend the connection since USB to RS232 adapters are fairly short. Here is a link to a known compatible USB to RS232 adapter supplied by Triangle Research: http://www.tri-plc.com/USB-RS232.htm RS485 All TRi ‘Super’ PLCs have a two-wire RS4 85 serial port (screw terminal connector) and can only interface to a PC via RS485 indirectly through a USB port. For USB connection, you will need a USB to RS485 adapter that plugs into the USB port of a PC and has a two wire connection to the PLC (usually labeled A & B or D+ & D-). Twisted pair cabling (shiel ded for noisy environments) should be added to the adapter to make a co nnection since USB to RS485 adapters would not typically provide wire connection.

120. Chapter 8 8-14 8.2.12 Set TAB Width You can change the number of spaces the editor used to display the <TAB> character that you insert to format the code hierarchically. 8.3 Controller Menu All commands in this menu are for communi cation with the PLCs via the TLServer or the Ethernet XServer. Hence the TLSe rver must be actively running and connected to the PLC(s) via its serial port before the commands here can be successfully executed. Note that TLServer can be running on the same computer that i-TRiLOGI is running on (using localhost IP 127.0.0.1) , or on another comp uter in the same local area network, or anywhere in the wo rld with an Internet connection. The experience is identical regardless of wher e the TLServer (and hence the PLC) is situated. Note: In order to maintain compatibilit y with the "Ethernet XServer" device which is not Unicode aware, the TL6 Application still uses standard ASCII encoding when communicating with the PL Cs. (This is unlike opening or saving i-TRiLOGI program files to the TLServer, that would require Unicode network stream as mentioned in the "Fil e" menu help page). As a result, the TL6 application can work with TLServer versio n 3.x as well as older TLServer 1.x and 2.x. when it is only for the purpose of programming/controlling and monitoring the PLC and not to read/write i-TRiLOGI file. If there is no existing connection made to the TLServer, then execution of any command in this menu will always bring up the password dialog for you to enter the Username/Password as well as the IP Address:port of the TLServer. You must be positively authenticated before you ar e able to log-in to the TLServer. See Log In to TLServer for detailed explan ation of the Username/Password Dialog box. Once you have log-in to the TLSe rver, see explanation of each function below: 8.3.1 Select Controller <Ctrl-I> The only editable field is the ID field. You have to enter the ID address in hexadecimal notation (00 to FF). This command allows you to select another PLC that is connected to the same TLServer but with a different ID for on-line monitoring or program transfer.

85. Chapter 6 6-11 5. Next, we want to insert the special bi t "Clk:0.5s" to the left of the "Manual" contact. Press the <SHIFT> key to move the insertion point to the left end of the highlight bar as shown above. Then left-click on the icon to create a normally-open contact. Scroll the I/O table to the "Special Bits" table and select the item: "0.5s Clock". The parallel branch would have been completed by now. Note: The "Special Bit" table comprise s some clock pulses and some other special purpose bits. These include the eigh t built-in clock pulses in the system with periods ranging from 0.01s to 1 minu te. Built-in clock pu lses are useful if you need a time base to create, for ex ample, a "flashing light". A contact such as "Clk:0.1s" will automatically turn itself ON for 0.05s and then OFF for another 0.05s and then ON again, result ing in a series of clock pulses of period = 0.1 second. 6. Next, move the highlight bar to the ri ght end junction of the parallel circuits as follow: 7. Now, click on the icon to insert a special function coil. A popup menu will appear for you to select the desired special function. Click on the item "4.[AVseq]-Advance Sequencer" to insert the Advance Sequencer function [AVseq].

88. Chapter 6 6-14 7. Since the custom function has not b een defined with a label name, you will be prompted to give it a label name. The label name given to the CusF must be unique and are subject to the same limitations as that of the I/O label names. Lets enter the label name "EventCount" for function #1. Note: Label name for Custom function is optional and if you don't wish to use label name then the program will automati cally assign it a name "Fn_#1" for function #1, "Fn_#2" for function #2, and so on. 8. When the Custom Function editor ha s been opened, enter the following text and then close the editor window by click on the or by pressing the <ESC> key. If you would like to exit the editor window without saving the changes, click on the button.

90. Chapter 6 6-16 the <Spacebar> to open up the comm ent editor window. You can use the normal text editing keys such as left, right, up, down cursor keys, and <Ctrl- Left>, <Ctrl-Right>, <Del> and <Backs pace> keys for editing the comment text. 6.6 Ladder Logic Programming Tutorial: STEP 6 The stage has been set and the show is ready! Having completed the demo program, it is time to test if it works as intended using the built-in real-time programmable controller si mulation engine. Open the "Simulate" pull-down menu and activate the command "Run (All I/O reset) - Ctrl+F9". i-TRiLOGI will immediately compile the ladder program and if no error is detected, it will instantly proceed to open up the "Pro grammable Logic Simulator" screen, as shown below: 1. If you have followed closely all the in structions during the creation of the demo program, you should not encounter any compilation error. However, if you do receive an error message, then please check your circuit against the picture shown in the assignment page , make all necessary corrections and then try again. 2. The simulator screen comprises 5 column s: Input, Timer, Counter/Sequencer, Relay, and Output. With the exception of the Relay table which contains up to 512 elements, and the Timer table wh ich contains up to 128 timers, all other columns contain 256 elements each. Every column has its own vertical scroll bar. You can use the mouse to scroll each column independently to locate the desired I/O.

136. Chapter 8 8-30 8.3.10.2 ADVANCED CONFIGURATION 1. MAC ID A read-only field that contains the 6 byte (48-bit) Ethernet MAC ID. 2. Trusted IP - MODBUS/TCP Access Security

140. Chapter 8 8-34 The zero offset error can be corrected by entering a value into the “ADC Zero Offset” field. Any number between – 100 and 100 can be entered here. The ADC(n) function would add the zero-offs et value that you entered here to the measured value and return the total sum to the calling routine. 4. DAC Calib. A value x entered in each of these fields represents the multiplication factor (1 + x/10000) that the PLC will apply to the “val ue” parameter, which is executed by the command “SETDAC n, value” before ac tually writing to the DAC output. This allows the user to apply a correction fa ctor to the DAC output if there is a problem with the DAC voltage. Example 1: If you execute “SETDAC 1,2048”, you would expect the DAC #1 to output 5.000V on a 10.000V full scale DAC, but instead you only get 4.960V. Proportional Error = 4.960/5.000 = 0.992 Multiplication factor required to co rrect the DAC output = 1/0.992 = 1.0081 = (1+81/10000) You can therefore enter the value “ 81” into the “DAC Calib.” field corresponding to DAC #1 and save the parameters to the PLC. After the PLC has rebooted, when you execute the statement “SETDAC 1,2048”, the CPU would apply the multiplication factor of 1.0081 to the actual digital value it sends to the DAC output. The actual DAC output =4.960V x 1.0081 = 5.000V. Example 2: Same as Example 1 but you measure 5.030V when you expect 5.000V Proportional Error = 5.030/5.000 = 1.006 Multiplication factor required to correct the DAC output = 1/1.006 = 0.9940 = (1 – 0.0060) You should therefore enter the value –60 into the “DAC Calib” field corresponding to DAC #1 and save it to the PLC. After the PLC has rebooted, when you execute the statement “SETDAC 1,2048”, the PLC will apply the multiplication factor of 0.9940 to 2048 before it writes to the DAC hardware.

156. Chapter 9 9-4 The same principles can be applied to internal bits and coils as were previously described for physical input contacts and output coils. Once you understand these fundamental principles of interpretting a ladder diagram, everything should become clearer and simpler. Ladder diagram programming can be used to create a rather sophisticated control system. However, In i-TRiLOGI we augment it s power further by allowing a ladder program to activate customized functions created in TBASIC. 9.1.2 Relay Coils A contact can also be activated by the presence of an electrical current. This makes it possible for a control system to control the turning ON or OFF of a large load by using electrical current to activate a switch that can conduct high current. The simplest form of this type of contact is a relay. In traditional electrom agnetic relay, a coil of wire is wound around an iron core which turns it into an electromagnet. W hen current passes through the "coil" the magnet is "energized" and the force is used to either close a contact (that makes it a normally-open contact, closed only when energized) or open it (that will be a normally-closed contact since it is closed when not energized). Ladder Logic programming language borro ws some of those terms used to describe the electromagnetic relay for it s own use. You connect a relay coil to the right end of the ladder diagram just like an output, as follows: In a PLC, there are hundreds of internal "relays" which are supposed to behave like the typical electromagne tic relay. Unlike an output (e.g. the "Lamp" output)

172. Chapter 10 Chapter 10 Introduction to TBASIC Custom Functions

174. Chapter 10 10-2 Alternatively, you can use <Ctrl-X>, which will cut the text (copy and delete). Once you have copied or cut the desired text, move the text editing cursor to the destination and press <Ctrl-V> to paste it to the new location. i-TRiLOGI 6.2 and up introd uces a brand new custom function editor. The custom function editor now has a whole new interface with split panes that provide text editing for writing code (just like before) on the upper pane and a web browser/TBASIC help information on the lower pane. The first time the custom function editor is opened after starting i-TRiLOGI, the text editor pane will be empty and the lower pane will display some information about Triangle Research, our products, or software update information (see below). The lower pane can also be used to display help or error messages when writing or compiling your program. Update : A define button has been added as of i- TRiLOGI version 6.42 and higher and a breakpoint feature for debugging purposes. 10.2.1 Split Pane Window The upper pane is used as a text editor for writing TBASIC code and the lower pane can either display information abou t Triangle Research (as shown above),

178. Chapter 10 10-6 10.2.3 Cursor Position In TRiLOGI 6.49 and higher the row and co l of the cursor position within the function editor is display on the right editor panel.

196. Chapter 10 10-24 When the program reaches a PAUSE stat ement it will enter a PAUSE Mode and you can then examine the variable in the PLC. You can add as many PAUSE statement as you need in different part of the program to halt the program execution. However, since the software does not show you exactly where the program is halted except to tell you th at a PAUSE statement is known to have been executed in a particular function number, and if you have more than 1 PAUSE statement in a particular custom function then you will need to put some markers so that you know where the prog ram has stopped. The marker could be displaying of some text on the LCD (e.g. "Pause @21") that a certain PAUSE point has been reached or you can assign a cert ain value to a reserved variable and the value corresponds to the location of your PAUSE statement. This unfortunately means that you need to mo dify your program in order to break the PLC program at a certain location. Although it may be only a small effort to add and delete PAUSE statements in the TBASIC program and then re-run the te st immediately duri ng simulation, if you don't use the simulator but instead de bug your program directly on the PLC, then you must re-transfer the program to the PLC every time you add or delete a PAUSE statement. This can be time cons uming if your program is large or you have a very long custom function. So t he new BREAKPOINT features described in the next section can be good a time saver. 10.7.2 Using Breakpoints Starting from i-TRiLOGI version 6.45 a new "Breakpoint" feature has been added to the program so that debugging can be more easily performed without the need to modify and transfer the program to the PLC. The Breakpoint feature is supported on all Super PLCs with firmware version r78 and above. The break point feature is always available to the si mulator in this software version but the program does not let you send the progra m break points to a PLC with firmware older than r78. To set a break point in any part of th e TBASIC program, open up the custom function and place the cursor on the li ne where you want the program to pause when it reach the line. Then click on the "Toggle Breakpoint" button to set the break point. A breakpoint that is set wi ll be shown up as a blue rectangular box around the line, as shown below:

197. Chapter 10 10-25 If you click on the "Toggle Breakpoint" button again the blue box will disappear, which means the breakpoint has been cleared. Note: 1. You can define up to a maximum of 8 breakpoints in a program. 2. Comment/Remark lines and blank line s are not compiled and breakpoint should not be set on any of these lines. 3. The breakpoints that you've defined are saved along with the program. Each breakpoint can be cleared indivi dually by placing the cursor on the breakpoint line and the click the "Toggle Breakpoint" button. If you wish to clear all breakpoints in the program yo u can click on the "Edit" pull down menu and select "Clear All Breakpoints". In TRiLOGI 6.49 and higher it is possible to find breakp oints that have been set by clicking on the button. This will iterate through all of the break points that have been set in the program.

222. Chapter 12 12-6 Syntax : EXIT Comments : This new command is only available to PLC with firmware version r75 and above. Instead of using the GOTO command to get out of the loop, the EXIT command will orderly end a WHILE..ENDWHILE loop or a FOR...NEXT loop and jump to the next statement after the ENDWHILE or the NEXT command Example : S = 1 WHILE S S = S+1 IF S >= 100 EXIT: ENDIF DELAY 1 ENDWHILE X$ = INPUT$(1) When S has been incremented to 100, the CPU will exit the loop and continue executing the command after the ENDWHILE statement, which is the X$ = INPUT$(1) statement. See Also : WHILE..ENDWHILE , FOR..NEXT , CONTINUE 12.12 FOR ... NEXT Purpose : To execute a series of in structions for a specified number of times in a loop. Syntax : FOR variable = x TO y [STEP z] . . . . NEXT where variable may be any integer variable A to Z only and is used as a counter. x, y and z are numeric expressions. STEP z is an optional part of the statement. x is the initial value of the co unter, y is the final value of the counter. Program lines following the FOR statement are executed until the NEXT statement is encount ered. Then the counter is

228. Chapter 12 12-12 Purpose : To return a string that represents the hexadecimal value of the numeric argument n. If the se cond format is used then this function will return a string of ‘d’ number of characters. Examples : A$ = HEX$(1234) B$ = HEX$(1234,7) Comments : A$ will contain the string : "4D2" , B$ will contain the string “00004D2”. See Also : HEXVAL( ), STR$( ), VAL( ) HEXVAL(x$) Purpose : To return the value of a hexadecimal number contained in the argument x$. Examples : B = HEXVAL("123")*100 Comments : B should contain the value 29100 (&H123 =291) See Also : HEX$( ) , STR$( ) , VAL( ) 12.21 HSCDEF ch, fn_num, value Purpose : Enable and set up parame ters for the High Speed Counters channel ch. These counters op erate independently of the ladder logic scan time and ca n capture high speed input pulses generated by position encoders. ch = channel number (1-8) fn_num = Custom Function # to trigger when value is reached. value = trigger when HSC reach this (32-bit) integer value. If the PLC supports quadratu re encoder inputs, then the HSC counter variable HSCPV[ch] will increment/decrement according to direction of rotation. When value is reached, the specified custom function activates immediately. Important : All High Speed Counters are disabled automa tically when the PLC is reset unless they ar e enabled by the HSCDEF statement. However, if more than one HSCDEF for the same channel ch is executed, only the last executed HSCDEF

242. Chapter 12 12-26 treated as the end of a string in TBASIC and will be ignored if you use PRINT #n statement to send out CHR$(0). Examples : OUTCOMM 2,225 12.40 PAUSE Purpose : To set a breakpoint for executing the CusFn. This is used mainly for debugging a CusFn. By Inserting a PAUSE statement at the place of interest, you can suspend the program execution when PAUSE is encountered, after which you may examine the values of the re levant variables. You can continue to perform on-line monitoring of the PLC that has been paused. Program execution can also be continued by pressing the <P> key during Simulation or On-line Monitoring. 12.41 PIDcompute(ch, E) Purpose : This function computes the output for the PID compensator/ controller, using the P,I, and D Gains defined in the PIDdef statement for the same channel ch. The integral and differential values are stored within the channel's internal data space and will be automatically used by the PID computation routine. The PIDcom pute( ) function uses the lmt (max. limit) term of PIDdef stat ement to limit the results of its computation. If the absolute va lue of the computed result is greater then "lmt", then the result will be set equal to "lmt" for +ve number and to "-lmt" for negative value. When this happens, the integral term will not accumulate the current error to prevent an "integra tor windup" which is very undesirable for the system. ch = channel number (1-16) E = Closed-loop Error. (i.e. Set point value - Feedback Value) The controller may obtain feedback from ADC, High Speed Counters, PULSEFREQUENCY or other means. The obtained result is then scaled and subtracted from the desired (set point) value to get "Err ". All computations are performed in

245. Chapter 12 12-29 12.43 PMON ch PMOFF ch Purpose : PMON enables Pulse Measurement Function at channel #ch, whereas PMOFF disables the channel. After enabling the channel, you may then use the functions PULSEWIDTH(ch) and PULSEPERIOD(ch) to obtain the width and period of the input pulses arriving at the pu lse measurement input pin. You must call PMON once during init ialization to enable the pulse measurement hardware. Otherwise the two functions will only return 0. You should avoid repeatedly executing PMON function, otherwise the pulse me asurement hardware will be reset repeatedly as well, an d accurate measurement cannot be obtained. If you no longer need to measure the pulse-width or period for a particular channel whic h has been PMON before, you should disable it using PMO FF to save CPU time because pulse measurement is interrup t driven and consumes CPU time. Example: PMON 1 : PMOFF 5 See Also : PULSEWIDTH( ) / PUSEPERIOD( ) / PULSEFREQUENCY 12.44 PRINT# n x$; y; z.... Statement Purpose : To send a string of ASCI I characters formed by its parameter list (x$; y; z) out of the PLC to other devices via the communication port #n. Parameters : n must be an integer constant of between 1 and 8. Integer value in the parameter list (y; z..) will be converted into the equivalent ASCII representatio n. Each parameter must be separated by the semicolon(;). Action : The ASCII string is first fo rmed by the PRINT statement using all the arguments in the argument li st and the completed string is then sent out of the serial channel #n at one go. The PRINT statement automatically sends a Carriage Return (CR-ASCII 13) out of the specified serial port after sending out the last

264. Chapter 12 12-48 Integers must be converted to string using the STR$( ) or HEX$( ) function to be accepted by this function. Special case: if n =0 the string x$ will be sent to the LCD’s “Instruction-Register” which allows hardware-specific LCD configuration such as clear screen, set cursor ON/OFF etc. (please refer to LCD’s manual for details) The parameter offset = 1 to 40 allows you to send the string x$ beginning from the offsetth position. Only the characters position to be occupied by x$ will be written to the display, other characters of the display remain unaffected. The PLC may support LCD display modules capable of displaying up to 4 lines x 40 characters per line of alphanumeric characters. If t he display has fewer lines or fewer characters per line, the unavailable lines or characters will be ignored by the PLC. Once set, the LCD display will latch the set value until the next SETLCD statement on the same line and same offset is executed. On the TRiLOGI simulator, the result of the SETL CD is displayed together with the Special Variables view screen. Examples : SETLCD 1,1,"This is a 1x20 LCD Display" 12.69 SETPASSWORD string Purpose : When this statement is executed, the PLC will not properly respond to any host link commands sent to it except the command “PWxxxx...xx” which must contains the same string “xxxx...xx” (not more than 19 characters) as defined in the SETPASSWORD command. All other commands will receive a “PWER” response indicating a “password error” state. Once the correct password has been accepted the PLC will work as normal and respond to all host link commands. Execution of “PW” host link command without any string will put the password lock back in force to prevent unauthorized access. Example : SETPASSWORD “I love TRiLOGI”

15. Chapter 1 I-TRiLOGI Setup Guide 1-2 j2re-1_4_2_19-windows-i586-p.exe Although your PC may already have a la ter version of JRE (in 2012 the latest JRE is version 7), it was discovered the JRE 1.4.2_19 is proven to work best with i- TRiLOGI software. This is especially so if your PC has a 64-bit Windows and some users reported that the JRE 7 on their 64-bit Windows did not work properly with I- TRiLOGI. You can install JRE 1.4.2_19 even if your PC already have other JRE versions. I- TRiLOGI software will automatically invoke JRE 1.4.2_19 if it is in stalled on your PC. JRE must be installed BEFORE installing the i-TRiLOGI software. First, double-click on the file "j2re-1_4_2_19-windows-i586-p.exe" to install the JRE. Please follow all instructions provided by the Install Shie ld program and install it onto the given default path (which is C:\Program Files\Java\ on 32-bit Windows and C:\Program Files (x86)\Java on 64-bit Windows. 1.4 Install i-TRiLOGI 6.x The following steps can be taken to install the i-TRiLOGI software: 1. After you have installe d JRE 1.4.2_19, then double-click on the "SetupTL6.exe" file (or the “Setup6xx.exe” file if you have downloaded the latest upgrade) to install I-TRiLOGI. 2. On any PC with an operating system that has user account controls, the first installation step will likely be a warn ing about an unknown publisher, as per the below screenshot. If this appears, click ‘Yes’ to continue. 3. Next you will be asked if you want to install the indicated version of i-TRiLOGI. Again, click ‘Yes’ to continue.

108. Chapter 8 8-2 8.1.1 New <Ctrl+N> Activate this command when you want to create a new ladder logic program. All current ladder circuits and custom func tions will be cleared from the screen and the default filename is "Untitled.pc6". 8.1.2 Save <Ctrl+S> This command saves the whole ladder logi c program, all I/O tables and all the custom functions to the disk . The current file will be saved to the same source from which it was opened from, i.e. If a file has been previously opened from the TLServer via the network, this command wi ll save the file back to the TLServer. Likewise, a file opened from the local harddisk will be saved automatically to the local harddisk. 8.1.3 Open (TLServer 3) - <Ctrl+O> This command is for loading a i-TRiLOGI pr ogram file "xxx.PC6" from the TLServer version 3.x or later. Due to the need to use Unicode in the network stream to handle Unicode-based ".PC6" file, this function on TL6 ca n only work with TLServer 3.x and above. Since TLServer 2.x does not support Unicode network stream this function will not work with TL Server 2.x. (If you attempts to execute "Open (TLServer 3)" and put in the IP addre ss of a running TLServer 2.x or earlier, TL6 will complain that the TLServer is no t running or unsuccessful connection to TLServer.) When selected, you will be prompted to enter the Username and the Password to gain access to the TLServer. (the sa me Username and Password must have already been defined in TLServer for this to work). If you are running i-TRiLOGI as a local application instead of as an appl et, you may be required to enter the "IP Address: port" of TLServer in order to connect to TLServer. (Note that last entry of IP Address: port is saved to the TL6 configuration file and will be loaded when the TL6 application re-starts). Each user has his own exclusive director y for storing his i-TRiLOGI files. Once authenticated, a network file dialog wi ll be opened for you to select a file, delete a file or create a subdirectory, as shown below:

24. Chapter 2 – Introduction To I-TRiLOGI Chapter 2 Introduction to i-TRiLOGI Client/Server Architecture

31. Chapter 3 3-3 Here is a link to a known compatible USB to RS485 adapter supplied by Triangle Research: http://www.tri-plc.com/U-485.htm 3.1.2 Ethernet Introduction All TRi Nano-10, FMD series, F-series, and newer PLCs have an Ethernet port built in, which can be used for programmin g and monitoring with the TRiLOGI software, as well as communication with other Ethernet devices and software. These PLCs can connect to the PC runni ng TRiLOGI many ways as follows: a) Wired connection to a router that the PC is also connected to (PC connection can be wired or wireless). b) Direct connection to the PCs wired Ethernet port via crossover cable c) Wireless connection to a wireless router if the PLC is connected to a wireless bridge (adapter) Only the first option, which is most common, will be described here. In a typical local area network (LAN) ther e would be one router (wired or both wired and wireless) that the network devices connect to, one modem that provides Internet to the router, and the devices connected to the router (such as the PLC and PC). Before You Begin The first thing you need to do is confi gure the network settings in the PLC to match those of the LAN. This is typically done as follows:

36. Chapter 3 3-8 a) Program Transfer b) Online Monitoring Whether you are connected to the PLC via serial port or Ethernet, you can now perform both of these tasks. If you ha ve connected via serial port, then TRiLOGI will connect to TLServer (must be running on the PC connected to the PLC). If you have connected via Ethernet, then TRiLOGI will connect to the PLCs web server, which is called FServer. First you will need to start TRiLOGI , which can be done from the Start menu. See section 1.5 Run TRiLOGI and TLServer for more details on starting TRiLOGI. The below window will open: For the purposes of this tutorial, the Demo .PC6 program will be referenced. This is a sample program that is included in the i-TRiLOGI installation. This sample program, as well as all the other included sample programs, are accessible from the “ C:\TRiLOGI\TL6\usr\samples ” folder. Below is the Demo.PC6 program:

59. Chapter 4: Using TLServer 4-16 window will pop up, as shown below, that allows you to enter the recipient email address. Once you have typed the recipients email address, you can press enter to send a default email (can't be changed). If it works, you will see a message window that says the email has been sent, as shown below, and you will receive an email with the following content: "Test Message sent from TLServer" If some settings in the email configurat ion are not correct or you do not have a working Internet connection, you will see an error message. If you use the TLServer email relay feature and encounter failure when the PLC attempts to email and if you cannot figu re out what caused the problems, then you can start upthe TLServer with Java Console enabled and re-run the email test with the "Debug" checkbox select ed. The Java console will output all interactive messages the TLServer exchan ges with the SMTP server. From the error messages produced you may be able to better figure out the cause of the email failure. Note: TLServer automatically enables deb ug messages when you use the "Email Test" button to send a test email via the SMTP server, regardless of the state of the "Debug" checkbox. The "Debug" checkb ox is effective only when TLServer carries out the the email relay oper ations on behalf of the PLCs.

73. Chapter 5 5-4 Note: The TLServer's root directory is not the same as the PC's root directory. In TLServer, the r oot directory is actually at "C:\TRiLOGI\TL6\public\". This is t he directory where the index.html and TL6Applet.jar file are stored and these files are served to the web browser when you enter the TLServer's IP Addr ess as mentioned above. Visitors have no access to the PC's file direct ory above the server's root directory so the content of your other PC files will not be at risk of being exposed to visitors to TLServer. Disabling TRiLOGI Applet If you want to prevent visitors to TLServer from loading TRiLOGI Applet at all, just remove the "TL6Applet.jar" file from the directory: "C:\TRiLOGI\TL6\public\". In that case you can only access the PLC using the TL6 application program.

79. Chapter 6 6-5 5. We have now completed defining the I/Os, timers and counters. Press the <ESC> key to close the counter or other tables. Note that not all labels need to be defined before programming. You may create the label names any timer during circuit creation by pressing hotkeys <F2>. 6.3 Ladder Logic Programming Tutorial: STEP 3 We are ready to create Circuit #1 as shown below: 1. With the circuit pointer (red colo r triangle) at Circuit #1, press the <Spacebar> to enter the "Ladder Edit" mode. You can also enter the circuit edit mode by double clicking at Circuit #1. Once you enter the "Ladder Edit" mode, a row of ladder icons appear along the top of the main i-TRiLOGI window just below the pull down menu. The following is a description of each it em. A yellow color highlight bar, which you can move to select an element in the ladder circuit, will appear.

95. Chapter 7 Chapter 7 i-TRiLOGI Ladder Logic Editor

142. Chapter 8 8-36 8.3.11 Auto Analog Calibration Available since version 6.43, this new An alog calibration tool allows OEMs to perform quick calibration of the PLC's analog inputs and outputs. This new tool is normally located under the "Controller" Menu. Alternatively, this tool may also be opened from the "E thernet & ADC Configuration Tool -> Advanced Config." by clicking on the button labelled "Auto-Calibrate Analog". The Auto Calibrate Analog I/O screen is sp lit into two parts. The upper portion is meant for calibration of the Analog inputs . The lower portion is for calibration of the PLC's analog outputs. We will explai n each part separately in the next few sections as you may only need to calibrate what you need to use. However, for those not too familiar with how to communicate with the PLC via i- TRiLOGI, go to section 4. Communicating with the PLC below that describes the connection procedure. 1. Analog Inputs (ADC) Calibration

161. Chapter 9 9-9 9.3.1 Reversible Counter Functions: [DNctr], [Upctr] and [RSctr] The [DNctr], [UPctr] and [RSctr] functions work toge ther to implement reversible counter functions on any of the 128 counters supported by i-TRiLOGI. The ordinary down-counter (created by clicking on the icon) essentially decrements the counter value by 1 from t he "Set Value" (SV) and will stop when its count becomes zero. Unlike the ordinary down-counter, a reversible counter is a circular counter which changes the counter present value (PV) between 0 and the SV. When you try to increment the counter past the "Set Value", it will overflow to become '0'. Likewise if you try to decrement the counter beyond '0', it will underflow to become the "Set Value". All three counter functions [DNctr], [UPc tr] and [RSctr] can operate on the same counter (i.e. assigned to the same counte r label) on different circuits. Although these circuits may be located anywher e within the ladder program, it is recommended that the two or three functions which operate on the same counter be grouped together in the follow ing order: DNctr], [Upctr] and [RSctr]. Note that NOT all three functions need to be used to implement the reversible counter. Decrement Counter [DNctr]

169. Chapter 9 9-17 9.4.1 Special Sequencer Functions Quite a few of the ladder logic special fu nctions are related to the use of the sequencer. These are described below: 1. Advance Sequencer - [AVseq] Increment the sequencer's step counter by on e until it overflows. This function is the identical to (and hence interchangeable with) the [UpCtr] function. 2. Resetting Sequencer - [RSseq] The sequencer can also be reset to become inactive by the [RSseq] function at any time. Note that a sequencer that is in active is not the same as sequencer at Step 0, as the former does not acti vate the SeqN:0 contact. To set the sequencer to step 0, use the [StepN] function described next. 3. Setting Sequencer to Step N - [StepN] In certain applications it may be more convenient to be able to set the sequencer to a known step asynchronously . This function will set the selected sequencer to step #N, regardless of its current step number or logic state. The ability to jump steps is a very powerful feature of the sequencers. 4. Reversing a Sequencer Although not available as a unique special function, a Sequencer may be stepped backward (by decrementing it s step-counter) using the [DNctr] command on the counter that has been de fined as a sequencer. This is useful for creating a reversible sequencer or for replacing a reversible "drum" controller. 9.4.2 Other Applications a. Driving Stepper Motor A sequencer may be used to drive a stepper motor directly. A two-phase stepper motor can be driven by four transi stor outputs of the controller directly (for small motors with phase current < 0. 5A) or via solid-stat e relays. The stepper motor can be driven using a sequencer that cycles through Step#0 to Step#3 (full-step mode) or Step#0 through Step#7 (half-step mode). Each step of the

170. Chapter 9 9-18 sequencer is used to energize different phases of the stepper motor. A clock source is needed to drive the stepper mo tor through its stepping sequence. The stepping rate is determined by the frequ ency (which is equal to 1/period) of the clock source. Clock pulses with periods in multiples of 0.01 second can be generated easily using the "Clk:.01s" bit and an [Upctr] function. For e.g., to generate a clock source of period = 0.05s, use "Clk.01s" to feed to an [Upctr] counter with Set Value = 4. The counter's contact (completion flag) will be turned ON once every 5 counts (0,1,2,3,4), which is equivalent to a 0.05 sec. clock source. b. Replacing a Drum Controller A drum controller can be replaced easily by a sequencer if the timing of the drum's outputs can be divide d into discrete steps. Assuming a drum controls two outputs with the timing diagram shown in the following figure: This can be replaced by an 8-step sequ encer. Step 1 (e.g "Seq1:1") turns ON and latch Output A using [Latch] function, Step 2 turns ON and latch Output B, Step 4 turns OFF Output A using the [Clear] fu nction, and Step 6 turns OFF Output B. All other steps (3,5,7,0) have no connection. 9.4.3 Program Example Assume that we wish to create a running light pattern which turns on the LED of Outputs 1 to 4 one at a time every seco nd in the following order: LED1, LED2,

181. Chapter 10 10-9 It is now possible navigate to any ot her function directly by choosing the function name from the “Select Function To Edit” drop box, as shown below. Alternatively, you can scroll from one cu stom function to the next one using the Fn Traverse2.jpg (1104 bytes) and Fn Trav erse3.jpg (1113 bytes) keys. However, clicking on the Fn Traverse1.jpg (1199 bytes) and Fn Traverse4.jpg (1122 bytes) buttons allows you to scroll to the prev ious or the next non-empty CusFn. All empty functions will be skipped. This is useful if you need to browse through all the custom functions to locate something. 10.2.6 View Other Custom Functions The "View Other Functions" choice box allows you to view another custom function via a read-only popup window without leaving the currently edited custom function. This is very conveni ent when you need to view the content of another custom function while editing one custom function.

291. Chapter 12 12-75 It is possible to break out of a WHILE loop using the GOTO command or the EXIT command (only on PLCs with r75 or higher firmware). Warning : Be careful that the WHILE loop will not be an endless loop as the PLC will appear to freeze up, being trapped in an endless-loop execution. TRiLOGI simulator attempts to detect this situation by giving a warning message if a loop is executed for an unduly large number of loops. Adding a break condition using GOTO or EXIT makes for more reliable WHILE loops. Examples : WHILE S = 1 IF INPUT[1] & &H0002: S = 0 : ENDIF ENDWHILE Execution will only be termin ated when input #2 is ON. WHILE loops may be nested; i.e. a WHIL E loop may be placed within the context of another WHILE l oop. Each Loop must have a separate ENDWHILE statement to mark the end of the loop. 12.92 WRITEMODBUS ch, DeviceID, address, data Purpose : Automatically write the 16-bit data to a MODBUS device using the MODBUS RTU/ASCII pr otocol. The communication baud rate is the default baud rate of that COMM port unless it has been changed by the SETBAUD command. Comments : The command automaticall y checks the response string received from the slave device for the correct LRC and the slave address. The status of th e operation can be checked by the user program by testing the STATUS(2) function, which will return a ‘1’ for successful command and a ‘0’ if there is any error or if the slave device is not present. Parameters : ch = PLC COMM port number. Range = 1-8 for MODBUS ASCII Range = 11-18 for MODBUS RTU (11 is com1, 12 is com2, etc)

324. Appendix 4 Appendix 4: A-4 PLC-to-Modem Communication Setup

101. Chapter 7 7-6 7.3 The Edit Menu 7.3.1 Cut Circuit You can remove a number of circuits from the current ladder program and store them temporarily in the clipboard for pa sting into another part of the present ladder program or into another file altoget her. In other words, it lets you move a block of circuits from one part of the ladder program to another part or into another file. Please note that you can't UNDO a Cut Ci rcuit operation. However, if you do make a mistake you can always paste it back in its original position. 7.3.2 Copy Circuit (Ctrl-C) You can copy a block of circuits from the current ladder program and store them into the clipboard for pasting in to another part of the present ladder program or into another ladder program file altogether.

217. Chapter 12 12-1 12 TBASIC KEYWORD REFERENCE 12.1 ABS(x) Purpose : To return the absolute value of the numeric expression x Examples : A = ABS(2*16-100) Comments : A should contain the value 68. 12.2 ADC(n) Purpose : To return the value fr om the Analog-To-Digital Converter channel #n. n should be between 1 and 16. Examples : A = ADC(2) Comments : n may be a numeric expression which returns a value between 1 and 16. If it is out-of -range, a run-time error will be reported and the function will be aborted. TRiLOGI software is able to support up to 16 channels of 16-bit bipolar ADC (which may has a range between -32768 and 32767. The actual number of ADC channels and the resolution will depend on the target PLC. Note: On the Legacy T100MD+ an d T100MX+ PLCs, there are 8 or less ADCs and all the A/D are normalized to 12-bit with a range of between 0 and 4096. 12.3 ASC(x$, n) Purpose : To return the numeric valu e that is the ASCII code for the nth character of the string x$. If x$ is a null string, ASC(x$,n) returns value 0. n may start from 1 up to the length of the string. Examples : B = ASC("Test String",6)

1. Programmer’s Reference i-TRiLOGI Ladder+BASIC Version 6.49 Revision 1.4

49. Chapter 4: Using TLServer 4-6 10, FMD and F-series PLCs will be forced to the default baud rate of 38400 bps with 8 data bits, 1 stop bit, and no parity when started in pause mode (for all 3 serial ports). These newer PLCs will NOT be forced to 9600 bps unlike that of the RS232 port on the M-series PLCs.Since the PLC's serial port is set to 9600 bps when power ON with DIP Switch #4 set, you will need to change the baud rate temporarily in order to communicate wi th the PLC (e.g to disable a program that causes trouble). However, do remember to change t he baud rate setting back to 38400 bps after you have reset the PLC with the DI P switch OFF, otherwise you may have problems communicating with the PLC later on since changes to comm settings are automatically saved. NOTE: The Nano-10, FMD and F-series PLCs will be forced to the default baud rate of 38400 bps with 8 data bits, 1 stop bit, and no parity when started in pause mode (for all 3 serial ports). These newer PLCs will NOT be forced to 9600 bps unlike that of the RS232 port on the M-series PLCs. 4.2.3 Modem Support 1. Dial Modem: TLServer 3.x incorporates support for dialing a modem connected to the PC's com port. This is us eful if the PLC has to be located at a remote location yet still has access to t he public telephone line or to a cellular phone. You can then connect the PLC to a standard analog modem such as the US Robotic 33.6Kbps or Hayes Acura smart modem. The TLServer can then dial the phone number of the remote modem and make a connection. Once a connection is established, the remote PLC is immediately accessible to client applications such as i-TRiLOGI or TRi-Exce lLink, etc over the Internet, Intranet or localhost as if it were connected to the TLServer via the serial port directly

81. Chapter 6 6-7 If you observe the highlight bar carefu lly, you will notice a dark green color square at the right end of the highlight. This indicates the insertion location where a series contact will be atta ched. You can change the insertion location to the left or the right of the highlight bar by pressing the <SHIFT> key or <TAB> key (Note: <TAB> key only works on JRE 1.3.1 or earlier. It does not work on JRE 1.4.x) 4. Next, create the contact "RUN" which is parallel to the "Start" contact by left- clicking on the icon. The I/O table will appear again. Scroll to the "Relay" table and select the "RUN" relay. 5. To insert the normally-closed "Stop" co ntact in series with the "Start" and "Run" contacts, you need to move the highligh t bar to the junction of the "Start" and "Run" contact. First click on the "Sta rt" contact to select it. Then click on the icon to move the highlight bar to the junction, as follow:

82. Chapter 6 6-8 Note: The highlight bar will move to the ju nction if you click on the dark green insertion point on the "Start" contact. 6. Next, right-click on the icon. It will change into yellow color normally- closed contact as shown in the abov e diagram. You are now inserting a normally-closed series contact at the lo cation of the highlight bar. Pick the "Stop" label from the "Input" table to add the series contact. 7. We will now connect a relay coil "Run" to the right of the "Stop" contact. Click on the icon to insert the coil. Select "RUN" label from the "Relay" table. Remember that an input can never be used as a coil. Fortunately, i-TRiLOGI is smart enough not to call up the "Inputs" table when you are connecting a coil, to avoid unintentional errors. Notice that the coil symbol ---(RLY) indicates that this is a relay coil, which is helpful in identifying the function of the coil. i-TRiLOGI automatically places the coil at the extreme right end of the screen and completes the connection with an extended wire.

86. Chapter 6 6-12 8. When prompted, select Sequencer 1. This function will increment the step counter of Sequencer #1 each time its execution condition goes from OFF to ON. Again, remember to press the <Enter> key to complete Circuit #2 6.5 Ladder Logic Programming Tutorial: STEP 5 1. Circuits #3 to #6 are similar to o ne another. They make use of the Sequencer to turn on the Outputs 1 to 8 to create a pattern of "running lights" when executed. The label "Seq1:1" of the cont act in Circuit #3 represents Step #1 of Sequencer 1. Remember that each sequencer can have up to 32 steps (Step #0 to 31), with each step indi vidually accessible as a contact. A normally-open contact "Seq1:1" will be closed whenever the step counter of Sequencer 1 reaches number 1. Likewise a normally-closed contact "Seq5:20" will be opened when the step counter of Sequencer 5 reaches number 20. 2. To create the normally-open co ntact "Seq1:1", left-click on the icon. When the I/O table pops up, scroll to t he "Special Bit" table and select the

133. Chapter 8 8-27 domain name (such as yahoo.com) and returns the IP address of the target server. You only need to fill in the DNS IP Address if you are asking the FServer to contact a remote server by domain name , instead of by IP Address. However, currently this feature is not supported on the FServer and hence it may be left as the default value of 0.0.0.0. 5. No. of Connections (FServer/ Modbus TCP) The F-series CPU assigns sufficient memory to support up to a maximum of 6 simultaneous TCP/IP connections to t he FServer and Modbus/TCP server. By default, each server is assigned a ma ximum of 3 connections each. However, to improve flexibility, you can re-assign the mix of maximum connections between the two servers as long as the no. of Modbus/TCP connections does not exceed 5 and the no. of FServer connections does not exceed 4. This means that you can define 1 to 4 FServer connections and 2 to 5 Modbus/TCP connections. When you change the number in one box the other box will change automatically so that the total number of possible connections remains at 6. 6. FServer Port No. The Port number is a 16-bit integer (range 0 to 65535) that needs to be specified on top of the IP address when accessing the FServer from across the network. The default value is 9080, which is the sa me default value used by the TLServer and i-TRiLOGI client software. Please se e the i-TRiLOGI prog rammer’s manual for an explanation of the use of the port number. One reason why you may want to change the port number is to use the “port forwarding” capability of an NAT router so that different F-series PLCs ma y be accessible from the Internet using the same public IP address of the router but with different port numbers. 7. Modbus/TCP Secondary Port No. According to MODBUS.ORG specifications, all Modbus/TCP servers must listen on port #502. However, Modbus.org also permits the device to be assigned a different secondary port number. As su ch, the Modbus/TCP server will always

138. Chapter 8 8-32 The bottom half of the "Advanced Conf iguration" screen contains ADC and DAC calibration constants that you can ent er and transfer to the PLC, as shown below: 4. ADC Calib. These fields are used to apply a multipli cation factor to t he value returned by ADC function. The multiplication factor = (1+ x/10000). Example 1: If you apply 2.500V to ADC #1 on a PLC with 5.000V full scale, you would expect the value returned by ADC(1) to be 2048. But the actual average reading centers around 2060. Proportional Error = 2060/2048 = 1.005859 Multiplication factor required to correct this error = 1/1.005859 = 0.9942 = (1 – 58/10000) => x = -58 You should therefore enter a value of 58 into the “ADC Calib” field for Ch #1 and save it to the PLC. After the PL C has rebooted, the CPU would apply the multiplication factor of 0.9942 to the re adings it received, which would correct the reading to: 2060 x 0.9942 = 2048. Example 2: If you apply 8.000V to ADC #8 on a PL C with 10.000V full scale, you would expect the ADC(8) function to retu rn a value of 8.000/10.000 x 4096 = 3277. However, your program returned a value of 3230 from ADC(8).

175. Chapter 10 10-3 or provide immediate help for any TBASIC keyword (as shown below). To use the lower pane for help on TBASIC keywords, simply select the keyword from the “Select Keyword” drop box or highlight the text in the editor. For Example: in the following screenshot, the code "SETLC D" is highlighted an d the syntax for "SETLCD" would be displayed as it is in the screenshot. 10.2.2 New Help Features. i-TRiLOGI Version 6.43 added the following useful features to its Help Pane: a) Select an I/O Label If the selected text is an I/O label name , the lower pane will display its I/O type and the I/O number as well as the cu stom function # where the same label name have been used. This can be very useful to find out where a certain variable may be changed in other custom functions.

191. Chapter 10 10-19 10.5.1 Simulation Run of CusFn. i-TRiLOGI fully supports simulation of all TBASIC commands. After you have completed coding a CusFn, test the effect of the function by connecting it to an unused input. Run the simulator by pres sing <F9> or <Ctrl-F9> key. Execute the CusFn by turning ON its control input. If your CusFn executes a command that affects the logic state of any I/O, the effect can be viewed on the simulator screen immediately. However, if the co mputation affects on ly the variables, than you may need to examine the internal variables. An I/O or internal relay bit that has been turned ON is indicated by a RED color rectangular lamp that simulate a LED being turned ON. You can pause the logic simulator at any time by pressing the <P> key or clicking on the [Pause] button. Likewise the simulator engine can be rese t by clicking on the [Reset] button. Simulation of ADC Inputs Along the top edge of the Programmable Logic Simulator screen, you will find 8 text fields adjacent to the label "ADC1-8". The programmer can enter the expected ADC values for ADC#1 to #8 in these text fields. In effect, these simulate the potential signal strength at their respective ADC input pins. These values will be captured by the TBASIC program when an ADC(n) command is executed in a custom function for ADC #n. Note: values entered at the ADC input te xt field will only be updated when the user press the <Enter> key or the <TAB> ke y to ensure that only finalized entries

118. Chapter 8 8-12 To do a global search, simply type the text in the same command line and click the "Find All" button. If the text is fo und in any custom function within the program, it will be highlighted in the text editor as shown below. Also, the text "Find in all CusF" will be displayed below the command line in the search area, indicating a global search. Each time t he "Find All" button is clicked, the next instance of the search text will be highlighted until the text cant be found anymore (in any custom functi on). At this point the first result will be highlighted again. If no text matches the search te xt, the message in the search area will change to "Text Not Found". NOTE: Highlighting of text found in the editor during a user initiated search or during compilation error tracking now works with JRE (Java Runtime Environment) 1.5 and 1.6 8.2.7 Goto <Ctrl+G> Use this command to move towards a specific circuit number. The "Goto" command is particularly useful if your pr ogram contains many circuits, and it is inconvenient to search for a particular circuit using the mouse or the cursor keys. 8.2.8 I/O Table <F2> Open up the I/O Table for de fining label names for the PLC's I/O. For detailed explanation of I/O tables, please click on the following link: I/O Definition Table 8.2.9 View I/O Type on Ladder <F3> Toggle between display or no display of the I/O type and physical I/O number for ladder logic contacts on the screen. All ladder logic contact symbols are

53. Chapter 4: Using TLServer 4-10 Double-clicking on an exis ting username opens up the username/ password dialog. You can now add password to the Administrator if you wish to prevent unauthorized access to the predefined usernames and passwords. There is also a pre-defined user named “samples” with no password where many samples TRiLOGI files are stored. If you select a username and then press the <DEL> key, you can delete the user provided its directory is empty. (You can use Window Explorer or TRiLOGI Application to delete t he contents of the user's directory first before deleting him/her from TLServer). 4.3.2 Add New User Clicking on this field allows you to a dd new users to the system. You can add as many users as you like subject to memory and hard disk limit. 4.3.3 Server Port If you click the check box to the left of the "Server Port" label, you can change the default "port" that the TLServer listens on. When the client accesses the TLServer. Whatever you define here must be matched by the same port number E.g. if the port number = 8000, then localhost access must be: http://127.0.0.1:8000/ However, if the port number is defined as 80 (default port for HTTP server), then you can access the server us ing just the IP address wi thout the port number: http://127.0.0.1/ 4.3.4 What Port Number Should TLServer Use? In most cases you can simply use the pr edefined port number “9080”. However, you may like to read the explanation box below regarding definition of a "Port". You can see that the default port for most public web-servers is port 80. You can define TLServer to listen at port 80 as well; in that case there is no need to specify the port number in the URL. However, there are reasons why you may or may

57. Chapter 4: Using TLServer 4-14 SMTP Mail Server: This will be the same Outgoing Ma il Server that you use in your email program such as the Eudora or Outlook Express. If in doubt, ask your ISP or System Administrator for help. This serv er must be setup properly before the TLServer can send any email. SMTP Port No.: This is the port that your Outg oing Mail Server will use to send emails. The default port number is 25, which is the most common port; however, some Mail Servers will use a different port and you should check with your ISP or System Administrator if you are not sure. Authentication: Some ISPs will only allow mail to be sent through their Mail Server if it originates from a trusted IP address (t ypically, only the Internet IP address that the ISP assigns to you). If this is t he case, then you may need to authenticate your IP address if it is different from the one provided to you (If you are sending mail from a location registered to another ISP using your Mail Server). If your ISP uses Authentication, then you will need to check the Authentication box and

97. Chapter 7 7-2 literal to indicate the I/O types and nu mber. e.g. i1=input 1, o12=output 12, r25= relay 25, t1= timer 1 and c5=counter 5. 5. <F5> - Refreshes the display. If fo r some reason the screen is garbled by incomplete circuit display, you can ju st press the <F5> key to redraw the screen. 6. <F7> - Opens any custom function. If the currently selected circuit contains a custom function, then it will be opened for editing. Otherwise i-TRiLOGI will ask you to select a custom function # from a menu. 7. <F8> - Compiles the i-TRiLOGI program to show the compilation statistics. 8. <F9> - Runs the simulator without resetting any I/O. 9. <Ctrl-F9> - Resets all I/Os and then runs the simulator. 10. <Ctrl-F8> - Resets all I/Os except inputs and then runs the simulator. 11. <Up>/<Dn><PgUp> and <PgDn> keys - Use the up/down cursor keys to move the marker to other circuits and the "Circu it #" display at the upper status line will simultaneously reflect the change. If you attempt to venture beyond the screen, the logic editor screen will sc roll. The <PgUp> and <PgDn> keys can be used to scroll one page at a time. 7.1.3 Navigating Circuits in Browse Mode Although most of the time you will prob ably be navigating the ladder circuit diagram using the scroll bar or cursor keys to find the circuit that you are looking for, there exist several short cuts to enable you to quickly jump to specific circuits in the program. E.g. If you select "G oto" from the "Edit" menu, you will be prompted by a “Goto Circuit” window to enter the circuit number to jump to immediately. You can also call up the “G oto Circuit” window by pressing <Ctrl- G> key anytime. If you have a large ladder program with mu ltiple rungs of circuits, then you will find the “Bookmark” feature very useful for quickly jumping from one circuit to another. The bookmarks appear as blue button along the top of the i-TRiLOGI editor windows: You can define up to five bookmarks by clicking on , each bookmark corresponds to a specific circuit #. By default all 5 bookmark points to circuit #1. Once you have defined the circuit # for a bookmark, then when you click on the bookmark button the editor instantly jumps to the pre-defined circuit number.

99. Chapter 7 7-4 7.2 The Circuit Menu 7.2.1 Insert Comments Comments are specific remarks used by a programmer to explain various characteristics of a program segment and are ignored by the compiler. i- TRiLOGI Version 6 allows comments to be freely inserted between circuits. Execute this command and the Comment Editor will be opened. The comment editor allows you to enter any text you li ke that best describe the working of the circuit. All standard text editing keys, including cut and paste are applicable to the Comment Editor. When you have fini shed editing the comments, click "OK" to accept the changes and to close the comment window or click abort to cancel the changes and close the comment window. Alternatively, you can press the <ESC> key to accept the changes and close the comment window. Once a comment has been created, it is assigned a circuit number and is treated like any other circuits. You can ed it it by pressing the <spacebar> when you are in Browse mode, al ternatively, you can move it around, copy it to another destination or delete it entirely using commands in the "Circuit" menu.

147. Chapter 8 8-41 If you are connecting to the PLC via TLSe rver that runs on the same PC as i- TRiLOGI, then simply select the "localhost-127.0.0.1:9080" to connect to TLServer. If you are connecting to the PLC's F-serv er, the IP address of the PLCs' and the port number should be entered in the "Server's IP Address:Port" field and select the corresponding radio button. The defaul t settings for the Ethernet port are IP: 192.168.1.5 and port: 9080 with no userna me and password required (same as shown in the screenshot above). Once you have entered the correct login information, click on the "De tect ID" button and wait for the PLCs ID to populate in ID box (01 is the default ID). T hen click "OK" and you are now connected to the PLC for any calibration work. 8.4 Simulate Menu i-TRiLOGI allows you to perform almost 100% simulation of your PLC's program off- line on your PC. This is a great tool for testing a program quickly before a machine has been manufactured. It is al so a wonderful tool for all new PLC programmers to practice their ladder lo gic programming skill without the need to purchase a PLC test station. i-TRiLOGI automatically compiles a la dder program before activating the simulator. If an error is found during compilation, the error will be highlighted where it occurs and the type of error is clearly reported so that you can make a quick correction. 8.4.1 Run (All I/O Reset) <Ctrl+F9> This should be the option to use when you first begin to test your i-TRiLOGI program. When executed, all I/ O bits (including inputs) are cleared to OFF state, all integer data are set to 0 and all stri ng data are set to empty string. Then the "Programmable Logic Simulator" wind ow will open for you to conduct the simulation test of your i-TRiLOGI ladder program. 8.4.2 Run (reset Except i/p) <Ctrl+F8> Very often you may wish to keep the in put settings "as is " when you reset the simulator. This situation is quite realisti c in the sense that when a PLC is powered- on, some of its inputs may already be in the ON state. (e.g. sensors may detect the end positions of a cylinder rod, etc) . This command allows you to preserve the logic states of all "Inputs" while rese tting all other data. Note that the <Ctrl- F8> key also works in the "Simulator" screen so that at any time you can reset the simulator without affecting the logic states of the inputs.

148. Chapter 8 8-42 8.4.3 Continue Run (no reset) <F9> Use this command to continue simulating the program since you last closed the simulator. All previous data are kept intact and will be used by the simulator to continue execution of the ladder progra m. If you have made changes to the ladder program or custom functions, the whole program will be recompiled before running. Note that first scan pulse (1st.Scan) wi ll not be activated when this command is executed since this is supposedly a cont inuation from the previous simulation run. This command can be useful if you have discovered a simple bug in your software during simulation, you can fix it immediately and test the effect of the change on the simulator instantly without restarting the entire simulation session from the beginning again. 8.4.4 Compile Only <F8> Allows you to compile the i-TRiLOGI file only in order to view the compilation statistics: 8.4.5 Reset All I/Os <Ctrl-R> Clears all I/Os in the simu lation engine without invoking the simulator. Since all I/Os whose logic states are turned ON in the simulator will also be shown as highlight on the ladder diagram, this offers a way to clear the I/Os if it hinders your viewing of the ladder program.

220. Chapter 12 12-4 12.8 CONTINUE Purpose : To command the CPU to jump to the next iteration of the WHILE..ENDWHILE or FOR..NEXT loop. Syntax : CONTINUE Comments : This new command is av ailable to all Super PLCs since firmware version r30. Upon executing the CONTINUE command the CPU will jump to the next iteration in the WHILE..ENDWHILE or FOR..NEXT loop. Example : FOR I = 1 to 10000 X = X + 1 IF INCOMM(1) < 0 CONTINUE ENDIF Y = Y + 2 NEXT If INCOMM(1) returns a -1 as in the second line of the FOR loop, the CPU will not execute the Y = Y + 2 statement, but will instead jump to the next iter ation, which is to increment index I by 1 and start executing the statement X = X + 1. See Also : WHILE..ENDWHILE , FOR..NEXT , EXIT 12.9 CRC16 (var, count) Note : {Applicable to all Nano-10, FMD Series, and F-series, but only to the legacy T100MD/MX PLC with firmware r44 or higher} Purpose : This function returns the computed CRC16 for a range of integers starting from variable “var” with the range indicated in the parameter “count”. CRC16 is a 16-bit version of “Cyclic Redundancy Check” – a popular mathematical formula for checking error in a data stream. Examples : DM[100] = CRC16(DM[5],8) X = CRC16(RELAY[2],4)

231. Chapter 12 12-15 1. This command is applicable only to Nano-10 and FMD PLC models with firmware >=r74 and I2C interface. 2. This command is ignored by i-TRiLOGI simulator. 12.25 I2C_STOP Purpose : Special command to gener ate an I2C STOP bit out of the PLC's I2C port (requires I2C-FRTC module to be installed). Examples : DM[5]= 12: DM[6]= 34 : DM[7]= 56 I2C_WRITE &H60,5,3 I2C_STOP Since the I2C_WRITE command does not automatically generate the STOP bit, this command is used to end I2C communication started by an I2C_WRITE command. See Also I2C_READ , I2C_WRITE Note: 1. This command is applicable only to Nano-10 and FMD PLC models with firmware >=r74 and I2C interface. 2. This command is ignored by i-TRiLOGI simulator. 12.26 I2C_WRITE i2cslave, dmstart, count Purpose : Special command to execute a I2C WRITE out of the PLC's I2C port (requires I2C-FRTC module to be installed). The CPU will send a I2C START, followed by the slave address byte (i2cslave) and count number of data bytes from the DM[dmstart] up to DM[dmstart+count-1] Comments : The command automatically checks for an ACK sent from the slave device, and the user prog ram can check the status of this operation by testing the STATUS(2) function. STATUS(2)

234. Chapter 12 12-18 ELSEIF or ELIF must be fo llowed by an expression to be evaluated (same syntax as for IF) and on the next line or followed by THEN there should be one or more lines of code to execute should the expression evaluate to true; however, the code is optional. ELSEIF is not the same as ELSE IF because the space indicates to the compiler that a new nested IF statement is beginning and this would require an ENDIF. Notes: Nesting of IF statement Statement blocks within the IF..THEN..ELSEIF..ELSE statement may contain other IF..THEN..ELSEIF..ELSE blocks (nesting). Each IF statement must be ended with the ENDIF statement. Otherwise an error message "IF wi thout ENDIF" will be reported during compilation. However, t he THEN, ELSEIF (or ELIF), and ELSE are all optional. Testing Equality: Special comparison oper ators may be used in the expression of the IF statement. Only integer expression may be compared. For comparison of strings, please refer to the "STRCMP(A$, B$)" function. Equal = Not Equal <> Greater than > Less than < Greater than or Equal to >= Less than or Equal to <= Examples : IF A >= B*5-20*C OR C=20 B = B-1 ELSEIF A < D B = B + 3 ELIF C = B A = C ELSE B = B*3 ENDIF

239. Chapter 12 12-23 leaves you 12000 - 2000 = 10000 bytes of FRAM space for storing 8-bit data starting from byte address space 2001 to 12000. Examples : DM[1] = LOAD_EEP8(10): A = LOAD_EEP8(2) relay[1] = LOAD_EEP(10): A = LOAD_EEP(2) DM32[1] = LOAD_EEP32(10): A = LOAD_EEP32(2) See Also : SAVE_EEP 12.35 LOAD_EEP$ (addr) Note : Applicable to all Nano-10, FMD Series, and F-series, but only to the legacy T100MD/MX PLC with firmware r44 or higher. Purpose : This function returns a string previously saved into the PLC’s internal data EEPROM using the “SAVE_EEP$ command. Examples : X$ = Load_EEP$(5) FOR I = 1 to 5 $$[I] = Load_EEP$(I+10) NEXT Comments : 1. String saved in EEPROM stri ng location #5 is loaded into X$ 2. Strings saved in EEPROM string locations #11 to #15 are loaded into A$ to E$ ($$[1] to $$[5] represents A$ to E$) See Also : SAVE_EEP$ for explanation of how the data EEPROM area are organized in these PLC’s to provide storage area for both integers and strings. 12.36 LSHIFT i, n Purpose : To shift 1 bit to the left the integer variable i which must be either an integer variable, a DM [n] or a system variable such as relay[n], output[n], etc. LSHIFT instruction permits more than one variable to be chained together before pe rforming a bit shift. The parameter n indicates the number of channels to be chained starting from i upward. n =1 if only one variable is involved.

240. Chapter 12 12-24 Examples : LSHIFT relay[2],3 Comments : The relay channels #2,#3, and #4 (which represent relays number #17 to #64 ) are chained together in the following manner: Bits are shifted from the lower channel towards the upper channel. Bit #15 of Relay[2] will be shifted into Bit #0 of Relay[3] and so on. Bit #15 of t he highest channel Relay[4] will be lost. See Also : RSHIFT 12.37 MID$(x$, n, m) Purpose : This function returns a su b-string of m characters from x$, beginning with the nth character. x$ - any string expression, variable or constant. n - any numeric expression producing a result of between 1 to 255 m - any numeric expression producing a result of between 0 to 255. Examples : A$ = MID$("Welcome to TBASIC",4,7) Comments : A$ should contain the string :"come to". 12.38 NETCMD$ (ch, x$) Purpose : This function sends a multi-point host link command string specified in the x$ via serial port #ch to another Nano-10, FMD series, F-series, or H-series/E10 PLCs (or the legacy M- series PLCs). It will then wait for a specified amount of time for a response string from the other PLC and this response string is then returned.

251. Chapter 12 12-35 Purpose : To perform a cold reboot of the PLC from within a CusFn. The effect is identical to a powe r-on-reset except that you execute this command without turning OFF power to the PLC. Comments : RESTART may be necessary for some changes to take effect, such as for the PLC to assume new IP address after executing the SET_IP command. Note : This command is ignored by i-TRiLOGI simulator. 12.52 RETURN Purpose : Unconditionally ends the execution of the current CusFn and return to the caller (which is either the ladder program or another CusFn which has executed a CALL command). Use of the RETURN statement is optional if there is no conditional ending required. After executing the last statement the CusFn will return to the caller automatically. See Also : CALL 12.53 RSHIFT i,n Statement Purpose : To shift the integer variable i 1 bit to the right. i must be either an integer variable, a DM[n] or a system variable such as relay[n], output[n], etc. RSHIFT instruction permits more than one variable to be chained together before pe rforming a bit shift. The parameter n indicate the number of channels to be chained starting from i upward. n =1 if only one variable is involved. Examples : RSHIFT relay[2],3 Comments : The relay channels #2,#3, and #4 (which represent relays number #17 to #64 ) are chained together in the following manner:

293. Chapter 12 12-77 Range = 11-18 for MODBUS RTU (11 is com1, 12 is com2, etc) ID - Device ID of the MODBUS slave device. Range = 1 to 255 addr - Zero-offset address of the holding register in the MODBUS slave device starting from 0 = 40001. var - the starting variable in the master whose data is to be sent out (may be a DM or any system variable) count - number of variables to send (max =16 in the legacy T100M Series PLCs). Example : WRITEMB2 13,5,101,DM[10],8 The PLC will use MODBUS RTU protocol, via its Comm port #3, to write 8 words of data from DM[11] to DM[17] to the slave MODBUS device with ID = 05 and into its register offset address 101 to 108 (in MODBUS term. these refer to the #40102 to #40109 holding registers) . See Also : READMB2 , WRITEMODBUS , STATUS(2)

294. Appendix 1 Appendix 1: PLC to PC Communications Setup - Hardware

102. Chapter 7 7-7 7.3.3 Paste Circuit (Ctrl-V) When you execute this command, the block of ladder circuit which you "Cut" or "Copy" into the clipboard will be past ed just before the currently selected circuit. The current circuit number will be adjusted to reflect the change. 7.3.4 Find (Ctrl-F) The Find command allows you to quickl y locate a ladder logic circuit that contains a particular label name. The Find command can also be used to search for a keyword in a TBASIC prog ram. When this co mmand is executed, you will be further prompted to select the option of searching for a ladder logic label or a text in a Custom Function. 7.3.5 Goto (Ctrl-G) Use this command to move towards a specific circuit number. The "Goto" command is particularly useful if your pr ogram contains many circuits, and it is inconvenient to search for a particular circuit using the mouse or the cursor keys. 7.4 The Circuit Editing Mode i-TRiLOGI comes with a smart editor which a llows you to insert or delete a single element within a circuit easily. The edit or interprets your circuit immediately upon entry and prevents you from crea ting illegal circui t connections. The functions of various keys in the circui t editing mode are detailed below. You know that you are in the circuit editing mode when a row of ladder logic icons appears along the upper status line nex t to the circuit number and a yellow color highlight bar appears and you can mo ve it to select an element in the ladder circuit, as shown below:

29. Chapter 3 3-1 3 INTERFACING TO THE PLC This chapter will discuss how to interface to the ‘Super’ PLC in terms of the most direct physical connection and the necessary software components for the purpose of programming and monitoring the PLC. These procedures will be covered in a bit of depth to explain certain aspects, so you may wish to reference the quick-connect guides instead, which are in the appendix of this document, if you wo uld like simple connection directions without explanations. Physical Connection There are two direct ways to physically connect to ‘Super’ PLCs for programming and monitoring from the i-TRiLOGI software: 1) SERIAL PORT (RS232 / RS485) 2) ETHERNET (Wired, RJ45 terminated) NOTE: There are other indirect ways to ph ysically interface to the PLC, such as serial/Ethernet radio, serial/Etherne t modem, wireless Ethernet bridge, XBEE radio, and others. Many of these are described further in subsequent sections of this document, independent documents, or the individual PLC reference manuals. Software Interface The i-TRiLOGI programming en vironment (client) is required to interface to the PLC for programming and online monitoring whether the physical connection is serial or Ethernet, but the server coul d be either TLServer or the FServer depending on the PLC model and type of connection. 3.1 Physical Connection Three methods of physical connection to the PLC are described here: Serial RS232, Serial RS485, and Ethernet.

47. Chapter 4: Using TLServer 4-4 4.2 Serial Port Setup 4.2.1 Setting Up and Testing TLSer ver's Serial Communication Port This dialog box allows you to configure the serial port of the host computer to match the setting on the PLC for proper communication. Most of the items here are self-explanatory. If you have more than one PLC connected to the host computer via RS485, all the PL Cs must have the same serial port settings as the TLServer. The button allows you to test whether the communication port is available to TLServer. You can also click the button to temporarily relinquish the port to other applications. Note that you will need to close an opened port before you can change its parameter. The (Command String) text entry field allows you to test communication with the PLC using its native or MODBUS ASCII pr otocols. If you enter a string here and press <Enter>, the ASCII string will be sent to the PLC connected to the serial port and the response string will be displayed in the bottom text box. If the comm port is not yet opened this command will automatically open it.

83. Chapter 6 6-9 8. Right below the relay coil is a parallel timer coil with label name "Duration". To create this coil, click on the icon. This allows you to connect a parallel coil to the existing coil. The "I /O" table will pop up for selection again. Since we want to choose a timer, scroll to the "Timer" table and pick the first timer with the label "Duration" to complete the circuit. Press the <Enter> key once to complete Circuit #1 9. Congratulations! You have just su ccessfully created you very own ladder logic circuit. It is that simple! It may be a good time to save your program now by pressing <CTRL-S> ke y or select "Save" from the "File" menu and give a file name for you new program. 6.4 Ladder Logic Programming Tutorial: STEP 4 We will now create Circuit #2 as shown below. 1. Follow the steps listed in STEP 3 to create the following circuit fragment: 2. We want to enclose the two series contacts "Step" and Manual" with a parallel branch that contains two element s. First, we will create the branch for the N.C. "Manual" contact.

134. Chapter 8 8-28 listen on port #502 for all of its connections by default. Should you choose to define a secondary port number, then the Modbus/TCP server will only listen on port 502 on one connection while the ad ditional connections (1 to a maximum of 4) would be listening on the secondary port. You may specify any port number between 1024 and 65535 (except for the port number already used by the FServer) to be the secondary po rt number. Please see the i-TRiLOGI programmer’s manual for an explanation of the use of the port number. One reason why you may want to change t he port number is to use the “port forwarding” capability of an NAT router so that different F-series PLCs may be accessible from the Internet using the sa me public IP addre ss of the router but with different port numbers. 8. Node Name You can assign up to 16 ASCII characters (any character) in naming a PLC. The node name is currently not used by t he network router so it is merely a convenient name for user to identify a PLC. 9. Username and Password (FServer only) You can use the username and passwor d feature to prevent unauthorized access to the FServer. It adopts the sa me proprietary encryption scheme used in the TLServer and i-TRiLOGI software to encrypt the password transmission. However, unlike the TLServer that allo ws you to define unlimited number of usernames and passwords, the FServer only permits a single username and password and this is limited to a length of 16 characters. 10. Use Username/Password (Yes/No) ? In applications where there is no danger of unauthorized access to the PLC via FServer, you can elect not to use the us ername/password. With the “No” option

153. Chapter 9 9-1 9 LADDER LOGIC LANGUAGE REFERENCE 9.1 Ladder Logic Fundamentals: Contacts, Coils, Timers and Counters 9.1.1 Contacts Ladder logic programs mimic the electric al circuit diagrams used for wiring control systems in the elec trical industry. The basic purpose of an electrical control system is to determine whether a load should be turned ON or turned OFF, under what circumstances and when it should happen. To understand a ladder program, just remember the concep t of current flow - a load is turned ON when the current can flow to it an d is turned OFF when the current could not flow to it. The fundamental element of a ladder di agram is a "Contact". A contact has only two states: open or closed. An open contact breaks the current flow whereas a closed contact allows current to flow through it to the next element. The simplest contact is an On/OFF switch which requires external force (e.g. the human hand) to activate it . Limit switches are those small switches that are placed at certain location so that w hen a mechanical device moves towards it, the contact will be closed and when t he device moves aw ay from it, the contact will be open. If a contact is connected to a load and the contact is closed, the load will be turned ON. This simple concept can be illustrated by the most basic ladder diagram as follow: The vertical line on the left is the "Pow er" line, current must flow through the "Switch" contact in order to turn ON the load "Lamp". (In fact, there should be a second vertical line on the right end of the ladder diagram to provide a return path for the current flow, but this is omit ted to simplify the circuit diagram). Now, if instead of wiring the switch to the lamp directly as suggested in the above diagram, you could connect the switch to the PLC's input and connect the lamp to the PLC's output, and then writ e the above ladder program to perform

157. Chapter 9 9-5 which has a physical connection out of the PLC, when an internal relay is turned ON, it is said to be "energized" but you will not see any changes in the PLC's physical I/Os. The logic state is kept intern ally in the PLC. The contact of the relay can then be used in the ladder diagram for turning ON or OFF of other relays or outputs. A relay contact in the ladde r diagram can be Normally-Open or Normally-Closed and there is no limit to the number of contacts a relay can have. 9.1.3 Out Coils A PLC output is really just an internal relay with a physical connection that can supply electrical power to control an extern al load. Thus, like a relay, an output can also have unlimited number of cont acts that can be used in the ladder program. 9.1.4 Timer Coils A timer is a special kind of relay that, w hen its coil is energized, must wait for a fixed length of time before closing its co ntact. The waiting ti me is dependent on the "Set Value" (SV)of the timer. Once the delay time is up, the timer's N.O. contacts will be closed for as long as it s coil remains energized. When the coil is de-energized (i.e. turned OFF), all t he timer's N.O. contacts will be opened immediately. However, if the coil is de-energized before the delay time is up, the timer will be reset and its contact will never be closed. When a last aborted timer is re- energized, the delay timing will restart af resh using the SV of the timer and not continue from the last aborted timing operation. 9.1.5 Counter Coils A counter is also a special kind of rela y that has a programmable Set Value (SV). When a counter coil is energized for the first time after a reset, it will load the value of SV-1 into its count register. From there on, every time the counter coil is energized from OFF to ON, the counter decr ement its count register value by 1. Note that the coil must go through a complete OFF to ON cycle in order to decrement the counter. If the coil remains energized all the time, the counter will not decrement. Hence counter is suitab le for counting the number of cycles an operation has gone through. When the count register hits zero, all the counter's N.O. contacts will be turned ON. These counter contacts will remain ON regardless of whether the counter's

173. Chapter 10 10-1 10 INTRODUCTION TO TBASIC CUSTOM FUNCTIONS 10.1 Overview i-TRiLOGI Version 6.xx supports user -created special functions, known as Custom Functions (the symbol CusFn will be used throughout this manual to mean Custom Functions). Up to 256 Cus Fns can be programmed using a special language: TBASIC. TBASIC is derived from the popular BASIC computer language widely used by microcomputer programmers. Some enhanc ements as well as simplifications have been made to the language to ma ke it more suitable for use in PLC applications. There are four simple ways to create a new CusFn: 1. From the "Edit" pull-down menu, sele ct the item "Edit Custom Function" and select the function number from a po p-up CusFn selection table which may range from 1 to 256. The selection table allows you to define unique and easily identifiable names for each custom function. Once you have selected the custom function the editor window will open up with the contents of that particular custom function. 2. You may also use the hotkey <F7> to open up the selection table. 3. If you have already created a ladder circuit which connects to either a [CusFn] or [dCusF] function (both appear as menu-items within the "Special Function" pop-up menu), t hen you can easily open up that particular CusFn by double clicking the left mouse butto n while the highlight bar is at the [CusFn] or [dCusFn]. Alternatively, you can open the CusFn by clicking the right mouse button while the highlight bar is at the [CusFn] or [dCusFn]. 4. You can open a custom function by cl icking on the "Open CusFn" button on the status bar below the pulldown menu.. 10.2 Custom Function Editor The custom function editor window allows creation of any number of lines of TBASIC program statements. Since this is a standard text editor, you should have no problem using the key and mouse co ntrols to edit the text. E.g. To copy a paragraph of text, select it usin g the mouse and the press <Ctrl-C>.

179. Chapter 10 10-7 10.2.4 Search / Find and Replace It is now possible to search for a word or phrase in the current custom function (local search) or in all of the custom fu nctions in your program (global search), and replace the text if desired. Local Search To do a local search, simply type the text in the command line below the "Find" and "Find All" buttons and then click the "F ind" button. If the te xt is found in the current custom function, it will be highligh ted in the text editor as shown below. Also, the text "Find only in this CusF" will be displayed below the command line in the search area, indicating a local search. Each time the "Find" button is clicked, the next instance of the search text will be highlighted until the text cant be found anymore. At this point the message in the search area will change to "Text Not Found" and the next time "Find" is cli cked, the first result will be highlighted again. Global Search To do a global search, simply type the text in the same command line and click the "Find All" button. If the text is fo und in any custom function within the program, it will be highlighted in the text editor as shown below. Also, the text "Find in all CusF" will be displayed below the command line in the search area, indicating a global search. Each time t he "Find All" button is clicked, the next instance of the search text will be highlighted until the text can't be found anymore (in any custom functi on). At this point the first result will be highlighted again. If no text matches the search te xt, the message in the search area will change to "Text Not Found".

193. Chapter 10 10-21 The second screen displays, in 25 pages, the values of the 16-bit DM variables from DM[1] to DM[4000]. Each page displays 16 rows x 10 columns = 160 DM variables. You can scroll up and down t he pages by clicking on the [PgUp] or [PgDn] buttons or using the corresponding keys on the keyboard. Starting from version 6.45 you can use tw o consecutive 16-bit DM variables as a single 32-bit DM32 variable in the follo wing manner: DM[1] & DM[2] = DM32[1]; DM[3] & DM[4] = DM32[2].... DM[2n-1] & DM[2n] = DM32[n]. A new button "View DM32[n]" is added and when cli cked, toggles the view of the DM variables between DM and DM32, as sh own below. The range of DM[1] to DM[4000] are mapped to DM32[1] to DM32[2000]. Note: Although this version of TRiLOGI allows you to view any super PLC's DM[] as DM32[] during online monitoring, only ne w Super PLCs with firmware version r78 or later is able to actually use DM32[n] in its program. i-TRiLOGI will check the PLC firmware version number during pr ogram transfer and will not transfer TBASIC program that contains DM32[] variables to those PLC with < r78 firmware. c) String Variable Screen The third screen displays the value of the 26 string variables A$ to Z$ in 4 pages, depending on the length of each string. If the execution condition is ON and the

225. Chapter 12 12-9 Purpose : To return the GATEWAY addr ess of this PLC's built-in Ethernet port and store each '.' separated valued in DM[dmindex] to DM[dmindex+3]. Comments : To return the GATEWAY a ddress of a PLC's Ethernet port into the variables DM[100] to DM[103] (e.g. to display on a HMI panel), you can invoke a function that runs GET_GATEWAY. Example : GET_GATEWAY 100 ‘ Return the DNS address Assuming the DNS address stored in the PLC is 192.168.1.1: DM[100] = 192 DM[101] = 168 DM[102] = 1 DM[103] = 1 Note : This command is ignored by i-TRiLOGI simulator. See Also : SET_GATEWAY , GET_DNS , GET_IPAddr , GET_SMTP , GET_SUBNET 12.16 GET_SMTP dmindex Purpose : To return the SMTP address of this PLC's built-in Ethernet port and store each '.' separated valued and the port number in DM[dmindex] to DM[dmindex+4]. Comments : To return the SMTP addre ss of a PLC's Ethernet port into the variables DM[100] to DM[104] (e.g. to display on a HMI panel), you can invoke a function that runs GET_SMTP. Example : GET_SMTP 100 ‘ Return the IP address and port Assuming the SMTP address st ored in the PLC is 192.168.1.101 and the SMTP port number is 587: DM[100] = 192 DM[101] = 168 DM[102] = 1 DM[103] = 101 DM[104] = 587

227. Chapter 12 12-11 See Also : SetCtrSV , SetTimerSV 12.19 GETHIGH16(v) Purpose : This function returns the upper 16-bit of a 32-bit integer variable v. This can be used to break the value of a 32-bit integer data or variable into two 16-bit values so that they can be saved to the EEPROM or to the DM[n]. Examples : DM[1] = GetHIGH16(A) save_EEP GetHIGH16(&H12345678), 10 See Also : SETHIGH16 GOTO @ n Purpose : To branch unconditionally out of the normal program sequence to a specified line with label @n within the present Custom Function. The destination line must have a corresponding line label marked as "@n", where n must be a constant within 0-255. Note that the label is local only to the present CusFn. i.e. another CusFn may have a label with the same n but the GOTO @n will only branch to the line label within the same CusFn. Examples : @156 SETBIT 0,3 . . . GOTO @156 Comments : An error message will appear during compilation if the destination label is undefined. 12.20 HEX$(n) HEX$ (n, d)

229. Chapter 12 12-13 statement will take effect. Hence you should put the next HSCDEF statement within the CusFn triggered by the first HSCDEF. By chaining the HSCDEF statement from one CusFn to another, you can control t he motion of the machine using the HSC value to execute a se ries of CusFn one by one. Within these CusFn you can program what to do to control the motion. E.g. changing the speed, putting on the brake, change direction of motion, etc. You can use the SETIO, CLRIO for digital ON/OFF cont rol and setDAC, setPWM for proportional control. Example : HSCPV[1] = 0 HSCDEF 1,19,-3310003 . . . . SETLCD 1,1,STR$(HSCPV[1],6) Comments : Enable High-Speed Counter #1 and make it activate function #19 when the counter reaches -33,100,003. Present value of HSC#1 was cleared to 0 before activating it. Note that TRiLOGI Version 5.x does not pe rform simulation of the High Speed counter operation since there is no High Speed Counter inputs on the simulator screen. Note that the HSDDEF statement will also activate the Pulse Measurement hardware as described in the Pulse Measurement section of the Nano -10, FMD series, and F-series User Manuals (does not apply to the legacy T100M series PLCs) See Also : HSCOFF 12.22 HSCOFF ch Purpose : Disable High Speed Counter #ch (ch = 1 to 8) If you no longer need the hi gh speed counter, it should be disabled in order not to waste the CPU’s time to service the interrupt generated by the change of state at the HSC input.. 12.23 HSTIMER n

289. Chapter 12 12-73 Purpose : To return a string which is an all-lowercase copy of A$. Examples : B$ = STRLWR$(A$)+Z$ C$ = STRLWR$(C$) Comments : The second example shows how to convert a string to all lower case. 12.86 STRUPR$(A$) Purpose : To return a string whic h is an all-uppercase copy of A$. Examples : B$ = STRUPR$(A$) C$ = STRUPR$(C$) Comments : The second example shows how to convert a string to upper case. 12.87 TESTBIT (v, n) Purpose : To return the logic state of bit #n of the variable v. The function returns 1 if the bit is ‘1’, otherwise it returns 0. Parameters : v = Integer Variable or Register. May be any integer variable, however, if v is a 32-bit integer TESTBIT will only test the lower significant 16 bits. n = Bit #. Range = 0 to 15. Comments : Following digital electronic s convention, bit 0 refers to the least significant bit (rightmost bit) and bit 15 the most significant bit. (leftmost bit) of the 16-bit integer variable. Please refer to page 10-4 in “C hapter 10: TBASIC Statements, Functions, Operators and Va riables” for the mapping between I/O bits and the variables. Examples : TESTBIT (Input[2],3) To test whether input #20 is ON

311. Appendix 2 A2-5 You should open the “samples” folder and select any files with “.PC6” extension for viewing. There are also sub-folders within the “s amples” folder where sample programs that relate to a particular topic or devi ce are stored, such as those relates to using the MD-HMI. We strongly encourage you to open these example programs to see how these programs are structured. Most of these programs can be run in the simulator except those that involv e communication with other devices or high speed counters. A2.2.1 Display Alphanumeric Messages on built-in LCD Display FMD series and F-series PLCs all come with a built-in LCD display port that allows low cost connection to industry standa rd LCD display module. For such PLCs, programming of the LCD display is vi a the SETLCD statement supported by TBASIC language. Assignment: Every 1 second, display a message as follow: Where xx depends on reading of A/D #1 which is returned by function ADC(1). Temp. Check Sitting Rm = xx o C.

22. Chapter 1 I-TRiLOGI Setup Guide 1-9 along the bottom of the screen an d check the “Show Quick Launch” option in order for the quick launch tool bar to appear: 1.6 Using TRiLOGI 6.x with International Languages The main improvement in the new i-TRiL OGI version 6.x and its accompanying TLServer 3.x is that in version 6.x, a ll data file storage and communication are conducted using the international standa rd “Unicode” (UTF-16) instead of the ASCII code found in the earlier versions of TRiLOGI software. When used with Unicode-aware Operating System such as the Windows 2000 and XP, it is now possible to create program that uses non-Latin based characters such as the Chinese, Japanese, Korean (also known as CJK), Thai, Hebrew, and Arabic etc in their comments and I/O label fields. In addition, version 6.x also includes some enhanced capabilities such as a EEPROM manager that allows reading/writing of the PLC’s data EEPROM directly within the TRiLOGI software. Internet TRiLOGI version 6.x and TLServer 3.x also allow users to customize their menu and on screen display so that th e menu, screen display and some online help texts may be shown in other intern ational languages including the CJK. There is even an option in the language text file for you to increase the text size by several points to make it clearer to display some international characters such as Chinese, or simply to make it easier to read the menu and help text. Several language files are currently avai lable for download from the I-TRiLOGI upgrade website: Language ISO Abbreviation Language specific file English en en_language.txt Spanish es es_language.txt Chinese Zh zh_language.txt Users of other international languages ca n create their own specific language help text by copying the “en_language.txt” file into a file named as “xx_language.txt” where xx is the two character ISO abbreviation of the language. For example, to create a Korean language help text, you need to copy the “en_language.txt” file into a file name: “ko_language.txt” and then edit the file to translate the relevant English text into Korean language. Even

115. Chapter 8 8-9 NOTE: You can select the range of Custom Functions you want to export to a "txt" file, just like you can select the range of Functions you want to print. Export #Define Table The new #Define Table feature introduced since version 6.43 can be exported to a ".txt" file that can be opened any text editing program or MS Excel program. To export Custom Functions, just choose the "#Define " option from the Print Control Panel and click on the button. 8.1.9 Exit Execute this command to exit orderly fr om the i-TRiLOGI program. You will be prompted to save the current file if the contents have been edited and the changes have not yet been saved. 8.2 Edit Menu 8.2.1 Abort Edit Circuit Changes made to the current ladder circui t can be aborted if you execute this command before pressing <Enter> to accept changes made to the current circuit. If changes have already been accepted by pressing the <Enter> key, then this command will have no effect. Th is command is useful if you wish to completely abandon changes you have made to a circuit without going through all the undo steps.

50. Chapter 4: Using TLServer 4-7 Notes: • Due to the time delay for modulati on/demodulation process as well as transmission delay, two-way commu nications via modem tends to be noticeably slower than connection made by direct cable connection. This is quite normal and does not indica te a problem with the communication setup. • The PC's modem must be able to emulate the COM port of the PC in order for the TLServer modem function to work. Some of the newer computers employ "win modem" or "soft modem" which may only work with Windows' dial-up networking. These kinds of modems are implemented in software and they do not necessarily emulate a standard PC COM port properly. They also de mand quite a bit of CPU power to process the communication properly. Therefore these type of modems may not work too well with the TLServer . If your built-in soft modem does not work properly with TLServer, you should get an external PCMCIA card modem and these are quite inexpensive nowadays and they will work much better with the TLServer modem support function. To setup TLServer to dial a modem, firs t close the active COM port by clicking on the "Close Port" button. Select t he COM port where the modem is connected to. (you can find out the which COM th e modem is connected to by checking the "Control Panel -> Mode ms -> Properties") Cli ck to select the "Modem" checkbox. You will then be able to ent er a telephone number to dial. The 3 buttons: "Connect", "Hang Up" and "Special" become enabled when you select the "Modem" mode. Note that the "Baud Rate" field now becomes the "DTE speed" which specify the line rate be tween the PC and the modem (this has nothing to do with the actual baud rate between the modems which will be automatically negotiated based on the quality of connection). Normally you should leave the DTE speed set to the highest value (115200) unless your modem manufacturer specifies other wise. The PLC can be operating at a different baud rate from the PC to modem-line-rate because of the modu lation/dimoduation action of the modem. * Important: The PLC-to-modem connection must be properly prepared before you can use TLServer to connect to the PLC's modem. You can find more details about this in the " PLC-to-Modem Communication Setup " appendix. Once you have entered a proper phone number, click on the "Connect" button to start dialing the modem (make sure that the "Auto Answer" check box is not checked). If the remote modem is busy or does not answer the call you will see

52. Chapter 4: Using TLServer 4-9 Some sample ".PC6" programs that enable a PLC to dial in to the TLServer and request for file or email services are provided in the following folder: "C:\TRiLOGI\TL6\usr\samples\FileService_Modem" To prevent unauthorized incoming call , you can specify a "Call-In Password" string as described above. If the "Call-In Password" contains any text other than an empty string, then the incoming calle r, upon connection, must immediately send a CR-terminated string that matches t he "Call-In Password" string in order to maintain the connection. If the pa ssword is incorrect the TLServer will disconnect the remote modem to prevent unauthorized access. If the call-in password is validated the TLServer will acknowledge this by sending a CR- terminated string "<OK>" to the remote PL C via the modem. It is the duty of the incoming caller to check the acknowledgement string to ensure that the connection is not dropped by the TLServer. 4.3 Configure Users By definition, only the “Administrator” is authorized to add/delete users and change password. Hence when you click on the “Configure Users” button, you are assumed to be the Administrator and you will be asked to enter the Administrator’s password to gain entry. By default, no password has been defined for the Administrator , so you should just press <Enter> key to gain entry the first time. Once you get through the Administrator Login screen, a dialog box will popup, which allows you to add new users who are allowed access to the TLServer and the PLCs. You can also change the passw ord, username or the access level of an existing user or delete an existing user. A new us er defined here will be given his/her own exclusive subdirectory to store ladder programs. For PCs, this directory is located at: "C\TRiLOGI\TL6\usr\<username>" where <username> is the same as the Username defined here. 4.3.1 Select Username

150. Chapter 8 8-44 select a destination circuit location and press <Enter>. The selected circuit will be moved to the new location before the destination circuit. Note that if you wish to move a block of circuits to a new location, you may find it more productive to use the "Cut Circuit" and "Paste Circuit" commands in the "Edit" menu. 8.5.4 Append Circuit Execute this to add a new circuit to the ladder logic program. This new addition will be positioned immediately after the last circuit in the entire program. 8.5.5 Delete Circuit This command allows you to delete the one or more circuits. You will be prompted to enter the range of circuits th at you wish to delete. Please note that you can't UNDO a delete circuit operation. 8.6 Help Menu All contents in this manual are availabl e for instant reference on the computer where the TRiLOGI program is running. Th is includes running the “applet” version of TRiLOGI program on a remote browser because the relevant help files will be retrieved from the TLServer automatically. You can call up the help files anytime by pressing the <F1> key. You can also select the “Content” item from this “Hel p” menu to bring up the content page of the entire on-line TRiLOGI help files. On the content page you can find the links to the Ladder Logic Editor and the entire TBASIC language reference. There is a “TRiLOGI Upgrade” link in the Help menu that allows you to obtain the latest Internet TRiLOGI upgrade setup program from the Internet. Simply follow the instruction to enter the website us ing the supplied username and password to obtain upgrade. On TRiLOGI version 6.1, there is also a special command called “Chinese LCD Code Converter” on the Help menu. This is to help generate the escape sequences for special LCD model that can display Chinese characters. Its function will be covered in the Chinese LCD installation and user guide and is not needed by non-Chinese LCD users. Instant Help for TBASIC Keywords

163. Chapter 9 9-11 b) If the counter's present value (PV) is equal to the Set Value (SV, defined in the Counter table), load the counter register with number '0000' and turn on the counter's contact (also known as the completion flag). c) Otherwise, increment the counter PV register by 1. Reset Counter [RSctr] When the execution condition of this function changes from OFF to ON, the counter will reset to its inactive state. This function is used to reset both a reversible counter and an ordinary down-counter coil. 9.3.2 Sequencer Functions: [AV seq], [RSseq] and [StepN] Please refer to the documentation on Using i-TRiLOGI Sequencers 9.3.3 Latch Relay Function [Latch] Latching relay is conveni ent for keeping the status of an execution condition even if the condition is subsequently re moved. The program elements that are assigned as Latching Rela ys will remain ON once they are energized. Only Relays and Outputs may be a ssigned as Latching Relays. On selecting [Latch] function, you can use the left/right cursor keys or click on the left/right arrow keys to move be tween the Relay and Output tables. The selected relay or output will now be assi gned as a Latching Relay. You will be able to see the label name of the prog ram element above the [Latch] symbol in the ladder diagram. Although latch-relay can be used in place of self-latching (Seal) circuits, a latch- relay in an interlock section will not be cleared when the interlock occurs. Only a self-latching circuit as shown in the fo llowing will be cleared in an interlock section:

188. Chapter 10 10-16 This is often not desirable and the coil created using this menu item will be highlighted in RED color to serve as an alarm to programmer. You will probably find that you will use the differentiated version [dCusF] far more frequently. 10.4.2 Periodic Execution of a Custom Function There are many situations when you need the PLC to periodically monitor an event or perform an operation. For example, to monitor the temperature reading from a probe or check the real time clock for the scheduled time, and to continuously display chan ging variables on the LCD di splay. It is not efficient to use the continuous [CusFn] function fo r such purposes. It is far better to use the built-in clock pulses to trigger a di fferentiated Custom function [dCusF]. You can choose a suitable period from 0.01s, 0.02s, 0.05s, 0.1s, 0.2s, 0.5s, 1.0s and 1 minute for the application. Other period s can also be constructed with a self- reset timer. The custom function will only be executed once every period controlled by the system clock pulse or the timer, as follow: For example, you don’t need to update the value of a variable displayed on the LCD screen any faster than the human eye can read them. So using a 0.5s clock pulse may be sufficient and this wi ll not take up too mu ch CPU time for the display. For slow processes such as heating, a 1.0s clo ck pulse to monitor temperature change is more than sufficient. IMPORTANT 1. When the CPU scans the ladder logic to a circuit which contains a CusFn, and the execution condition of the circ uit is TRUE, the corresponding CusFn will be immediately executed. This mean s that the CPU will not execute the remaining ladder circuits until it ha s completed execution of the current CusFn. Hence if the CusFn mo difies a certain I/O or variable, it is possible to affect the running of the remaining ladder program. 2. Note that the INPUT[n] variables cont ain data obtained at the beginning of the ladder logic scan and not the actual state of the physical input at the time of the CusFn execution. Thus, it will be futile to wait for the INPUT[n] variable to change inside a CusFn un less you execute the REFRESH statement to refresh the physical I/O before you examine the INPUT[n] variable again.

214. Chapter 11 11-11 With i-TRiLOGI version 6.2 and above, you can now attach comments to any variable name of any length to make pr ogram easier to read. See section 10.3.4 (String Variable Comments) below for more details. 11.3.3 String Operators a) Assignment Operator A string variable (A to Z, DM and system variables, etc) may be assigned a string expression using the assignment statement: A$ = "Hello, Welcome To TBASIC" Z$ = MID$(A$,3,5) b) Concatenation Operators Two or more strings can be concatenated (joined together) simply by using the "+" operator. e.g. M$ = "Hello " + A$ + ", welcome to " + B$ If A$ contains "James", and B$ contains "TBASIC", M$ will contain the string: "Hello James, welcome to TBASIC". c) Comparison Operators Two strings may be compared for equality by using the function STRCMP(A$,B$). However, the integer comparator such as "= ", "<>", etc cannot be used for string comparison. d) Functional Operators TBASIC supports a number of statement and functions which take one or more string arguments and return either an integer or a string value. e.g. LEN(x$), MID$(A$,x,y), PRINT #1 A$,.... SETLCD 1, x$ VAL(x$), 11.3.4 String Variable Comments With i-TRiLOGI version 6.2 and above, you can now attach comments to any variable name of any length to make pr ogram easier to read. The compiler will ignore any alphanumeric characters (A to z, 0 to 9 and ‘_’) that are attached

235. Chapter 12 12-19 Comments : A few comparison expressions may be linked with logical- AND (AND statement) or logical-OR (OR statement) operator as shown in the above examples. 12.28 INCOMM(ch) Purpose : To return a single 8-bit binary data obtained from Comm. channel # ch. ch must be a numeric consta nt between 1 and 8. The actual target hardware determines the valid port #. This function returns -1 if there is no data waiting at serial port. Example : FOR I=1 to 100 DM[I] = INCOMM(2): IF DM[I]<0 RETURN :ENDIF NEXT Comments : Usually the PLC buffers the se rial data arriving at its COMM port so that the program does not need to continuously check the COMM port for data. When the program is ready to process the data it can use the FOR..NEXT loop shown in the above example to read in all the data in the COMM buffer until it encounters a -1, which indicates that the buffer is empty. Note: INCOMM is supported on all COMM ports of the Nano-10, FMD series, and F-series families of PLCs (as well as the legacy T100MD/T100MX PLCs). See Also : OUTCOMM , INPUT$( ) , PRINT # 12.29 INPUT$(ch) Purpose : To return a string obtai ned from communication port # ch. ch must be a numeric consta nt between 1 and 8. The actual target hardware determines the valid port #. This function returns an empty string if there is no valid string waiting at serial port in order not to hold up the CPU. Example : For I=1 to 1000 ‘loop 1000 times

253. Chapter 12 12-37 space. Byte, Word and Long Word Addressing: Note that the FRAM space for 8-bit, 16-bit and 32-bit SAVE_EEPXX and LOAD_EEPXX commands are the same space and they are mapped as shown below SAVE_EEP32 SAVE_EEP16 SAVE_EEP8 1 1 and 2 1, 2 3 & 4 2 3 and 4 5,6,7,8 ... ... ... N 2N-1 & 2N 4N-3, 4N-2, 4N-1, 4N If you intend to use the EEPROM/FRAM space to store more than 1 type (8, 16 or 32-bit) of data then you must properly manage the EEPROM/FRAM data space reserved for storing each type of data so that they don't overwrite each other address space. The easiest way is always to reserve enough space for 32-bit data, followed by space reserved for 16-bit and/or 8 bit data. E.g. If you have 6000 words (16-bit) of FRAM space - this means you have space for storing 6000*2 = 12000 bytes of 8- bit data and you only have 6000/2 = 3000 long words for storing 32-bit data. Now assume that your program needs to store up to 500 x 32- bit data and the balance for storing 8 bit data. If you reserve 500 long words for 32-bit data, that means you are using up 500*4 = 2000 bytes of the FRAM space. This leaves you 12000 - 2000 = 10000 bytes of FRAM space for storing 8-bit data starting from byte address space 2001 to 12000. Please refer to your PLC’s reference manual for the upper limit of available FRAM/EEPROM storage. Parameters : data - May be an integer constant or variable. addr - EEPROM/FRAM address for data storage.

325. Appendix 4 A4-1 A-4 PLC-to-Modem Communication Setup A remotely located Nano-10, FMD series, or F-series PLC can be connected to a host PC via public-switch telephone network (PSTN), radio or cellular phone network. This can be accomplished by using two analog modems, one connected to the PLC’s RS232 serial port, and another modem connected to the remote host PC as follow: There are a some technical issues that n eed to be handled carefully in order to successfully implement the modem-linked host communications as described in the following sections. A4.1 Modem Connection Modem 1 : The host PC may use any intern al or external modem that can communicate at 2400 bps or faster. Connec t the modem to the PC as instructed in the modem’s manual and connect the phone line to the phone jack on the back of the modem marked "WALL" or "Line". TRi 'Super' PLC

116. Chapter 8 8-10 8.2.2 Undo <Ctrl+Z> Undo the last changes made to a ladder circuit. i-TRiLOGI automatically stores the last 10 edited steps so you could ex ecute undo several times to restore the circuit back to its original shape. 8.2.3 Cut Circuit - <Ctrl+X> You can remove a number of circuits from the current ladder program and store them temporarily in the clipboard for pasting into another part of this ladder program or into another file altogther. In other words, it lets you move a block of circuits from one part of the ladder progra m to another part or into another file. Once you execute the "Cut Circuit" command, a prompt box as shown below will appear. You have to specify the rang e of the circuits you wish to cut and press the "Yes" button to remove them from the ladder program. Please note that you can't UNDO a Cut Circuit operation. 8.2.4 Copy Circuit (Ctrl+C) You can copy a block of circuits fr om the current ladder program and store them into the clipboard for pasting into another part of this ladder program or into another ladder program file altogther. The range dialog box similar to "Cut Circuit" will appear for you to enter the range of circuit to copy. 8.2.5 Paste Circuit <Ctrl+V> When you execute this command, the bloc k of ladder circuit which you "Cut" or "Copy" into the clipboard will be pasted just before the currently selected circuit. The current circuit number will be adjusted to reflect the change.

307. Appendix 2 A2-1 A-2 Appendix 2 : Application Notes & Programming Examples A2.1 Important Notes to Programmers of TRiLOGI Version 6.x A2.1.1 Understanding Ladder Logic Execution Process Like all industrial PLCs, the CPU of the ‘S uper’ PLC first checks the logic states of the physical inputs and copies them in to memory. During the ladder logic scan the actual logic states of the physical Inputs (except for interrupt inputs) are ignored by the PLC. The CPU uses the memo ry copy of the inputs to execute the ladder program. The CPU executes its ladder logic progra m starting from the top rung of the program to the bottom rung. When t he CPU reaches a ladder rung that activates a {CusFn} or {dCu sF} that custom function will be executed. The CPU will only continue to scan the rest of the ladder program when the current custom function ends normally. Hence the order in which a ladder rung is placed within a ladder program can have an effect on the behavior of the program. Output bits which are changed as a result of the program execution will only be updated to the physical outputs at the end of the ladder logic scan. One scan time is defined as the time it takes to execute the 3 steps (read physical inputs, execute program, update physical outp uts). The CPU repeats these 3 steps continuously all the time, known as “Ladder Logic Scanning”. Hence, it is important to note that t he variables INPUT[n] s and OUTPUT[n] in TBASIC are not the actual physical I/Os of the PLC, but only a memory representation of the actual I/Os whic h will be updated only during the I/O update cycles. The logic states of physic al inputs are copied into the INPUT[n] variables during input scan and the physical outputs are set to the logic states contained in the OUTPUT[n] variables during output updates. Therefore, one potential error that tr aditional BASIC programmers tend to commit is to attempt to poll for a change in the variable INPUT[n] within TBASIC such as the following: W HILE INPUT[1] = 0 .. ENDWHILE

48. Chapter 4: Using TLServer 4-5 Note that only multi-point host link commands are accepted here. The only point-to-point command acceptable her e is the "IR*" command which queries the ID address of the PLC. If you have only one PLC connected to your TLServer computer, then you can test the communication now using the following command string: Command String : IR* Response String: IR01* The response string tells you that the ID address of this single PLC is 01. You can then try other host link commands using this ID address. (e.g. @01RI0000* to query the states of inputs #1 to #8) If you have more than one PLC connected you should not use the "IR*" since all connected PLCs will try to respond simultaneously, thus resulting in a garbage return string. To change the ID of a PLC, e.g., fr om 01 to 05, you can send the command string "@01IW0500*" to the PLC. There is also a button which does this for you automatically. You can click on the "Detect ID" button to check the current ID and then the "Change ID" button to write the new ID to the PLC. If the response string box become too cluttered, click the button to clear the response box content. The button can be used for comput ation of the "FCS" (Frame Check Sequence) characters from whatever te xt string you enter in the Command String box. In the above example, si nce there is currently a text string "@01RVIA" in the Command Stri ng box, clicking on the button will compute the FCS of the string "@01RVIA". You can then append the computed FCS to the command string to form a complete command string with FCS and send to the PLC: "@01RVIA4D*" 4.2.2 Changing Communication Settings Most likely you may want to leave the comm port settings at their default values: 38,400 bps, 8 data bits, 1 stop bit, no parity . One reason for changing the comm port settings may be due to the need to change the PLC's serial port to lower values (e.g. for communication via radio using 9600 bps). Changes to the comm settings are saved to the TLServ er configuration file: "TLserver1.cfg" when you quit TLServer. One other scenario is when you need to power cycle a M-series PLC with DIP switch #4 turned ON (to halt the CPU to disable the "1st.Scan" pulse). The Nano-

84. Chapter 6 6-10 3. Click on the element "Step" to highlight it. Then right-click on the icon to create a N.C. parallel circuit that encloses both the "Step" and the "Manual" contacts. A cross will appear at the left hand end of the "Step" contact, indicating that this is the star ting location of the parallel circuit. You should now click on the "Manual" cont act to select the ending location for the parallel circuit. The ye llow highlight bar will be positioned at "Manual" contact now. 4. You will notice that the icon has now changed into a yellow color N.C. contact with an opposite connection arm. You should now click on the symbol to close the parallel branch. (One possible short-cut method is to double-click at the ending location to close the branch). As usual an I/O table will be opened for yo u to select the I/O. For now, select the "Manual" label from the "input" table to create the following circuit:

180. Chapter 10 10-8 NOTE: Highlighting of text found in the editor during a user initiated search or during compilation error tracking now works wi th JRE (Java Runtime Environment) 1.5 and 1.6 Replace Text A replace feature is now available in the custom function editor below the Find/Find All text field in TRiLOGI version 6.49 and higher. To replace text, enter the new text in t he replace field and do a local or global search to find the text that is to be replaced. When the searched text is found and highli ghted as in the abov e figure, click on Replace and the text in the Replace fiel d will overwrite the highlighted text. The next instance of the text being searched (if any) will be highlighted automatically. Continue to click replace until all inst ances of the searched text have been highlighted and replaced. Replace will only replace and find text in the same function. Find All is still needed to search text outside the function that needs to be replaced. 10.2.5 Navigating Custom Functions

192. Chapter 10 10-20 are used by the TBASIC program. (otherwi se, imagine if you tr y to enter the value 123 at ADC #1, the program would first be receiving "1", then "12" and then "123" which was not the intention). 10.5.2 Viewing TBASIC Variables The values of the internal variables as a result of the simulation run can be viewed by pressing the <V> (which stand for "View") key or by clicking on the [View] button while in the simulation screen. A pop-up window will appear with the values of all the variables as well as special peripheral devices supported by TBASIC. The variables are organized into 4 screens. You can move from screen to screen using the left/right cursor keys or by clicking on the navigation buttons: a) Integer variables Screen The first screen comprises all 26 32-bit inte ger variables A-Z, the system DATE and TIME, ADC, DAC, PWM and the resulting va lues of setLCD commands. The initial DATE and TIME figures shown during simula tion are taken from the PC's internal real-time clock values. However, subseq uent values can be affected by the values assigned to the variable DATE[n] and TIME[n]. The present values of the first 3 high speed counters: HSC1 to HSC3 are also shown on this page. Note that ADC data for any particular A/D channel #n will only be shown if an ADC(n) function has been executed. Otherwise the ADC value shown on screen will not reflect the true current value of the ADC port. b) Data Memory Screen

194. Chapter 10 10-22 CusFn is not of the differentiated type , then the CusFn will be continuously executed. The result of the variable will be continuously updated on the viewing window. d) System Variable Screen System variables such as INPUT[n] , RELA Y[n] and emINT[n] are visible in this screen. You may wish to click on the [Hex] button to view the values in hexadecimal notation as they are more commonly used by programmers to identify the bit patterns in these variables. 10.5.3 Changing the Contents of Variables While the "View Special Variables" wi ndow is open, you may change the contents of the following variables by clicking on the [Edit] button: A-Z, A$ to Z$, DM[n], DM32[n], DATE[n], TIME[n], INPUT[n], OUTPUT[n], RELAY[n], TIMERBIT[n], CTRBIT[n], TI MERPV[n], CTRPV[n] and HSCPV[n], emINT[n], emLINT[n]. A text entry window will pop up and you will have to enter the values in the form of assignment statements, such as: A = 5000; DM[99]=5678; DM32[100]=&H12789ABC OUTPUT[2]=&H01AB B$ = "Welcome to TBASIC" The variable will take up the new value as soon as it is entered, and if the execution condition for any CusFn is ON , the simulator will process the newly entered data immediately and produc e the new outcomes. This gives you greater flexibility in controlling the simulation process. 10.5.4 Decimal and Hexadecimal Representation All the numeric data shown in the "Special Variables" window are by default displayed in decimal notation. You ca n display the number in hexadecimal format by clicking on the [Hex] button or by pressing the <H > key. Press the <D> key if you wish to switch back to the deci mal format. This feature is very useful for programmers who are familiar with hexadecimal representation of a binary number. The [Hex] button will become t he [Dec] button when you enter the Hex display mode.

199. Chapter 10 10-27 the breakpoint, you can send all your defi ned breakpoints to the PLC by clicking on this checkbox. i-TRiLOGI will connect to the PLC and check if the program in the PLC is the same as the currently open program by verifying the checksums. If the program is current then it will transfer all the defined break point to the PLC. With the checkbox shown as "checked" any subsequent addition or deletion of breakpoints will be immediately transferred to the PLC When the PLC program reaches the defined breakpoint it will stop execution and the PAUSE LED on the PLC will light up . If you then go online monitoring the program will open up the custom function and highlight the breakpoint line where the breakpoint was encountered. Note that the breakpoint sent to the PLC is volatile. If you reboot or power-on reset the PLC all the breakpoints will be disabled. This ensure that production PLC will not halt at any breakpoint that you forget to clear. To manually clear all the brea kpoints, you can un-check the checkbox and the i-TRiLOGI program will di sable the breakpoints in the PLC. If the checkbox was already unchecked but for some reasons the PLC breakpoints have not been cleared yet, then you will need to first check the checkbox to transfer the breakpoints to the PLC and then followed with an uncheck to disable them. If a PLC stops at a breakpoint that is no t defined in your current file then the i- TRiLOGI program will give you an alert an d will not be able to display the line where the program break. 10.8 Error Handling Since the CusFn text editor does not restri ct the type of text that may be entered into its editor, the i-TRiLOGI compiler will have to check the syntax of the user’s TBASIC program to look out for mis- spelling, missing parameters, invalid commands, etc. Such errors which can be tracked down during compilation process are know as "Syntax Errors". 10.8.1 Syntax Error i-TRiLOGI employs a sophisticated yet extremely user-friendly syntax error tracking system: When a syntax error is encountered, the compilation will be aborted immediately and the CusFn which contains the error is automatically opened in the text editor. The location of the offending word is also highlighted

249. Chapter 12 12-33 for 8 words of data starting from register offset address 101 (in MODBUS term this refer to t he #40102 holding register) . Once it receives the returned data t hese 8 words will be stored in the memory locations: DM[10], DM[11],.....DM[17]. This command automatically checks the response string received from the slave device for the correct slave address and LRC (or CRC16 RTU protocol is used). Like READMODBUS command, the status of this operation can be checked by the user program by testing the STATUS(2) function. Special : This command by default uses MODBUS function 03 to perform the read, which means th at it is designed to read from holding register addresses (4-xxxx). You can force it to change to using function 04 in order to read from addresses 3-xxxx by executing SETSYSTEM 6,4 (only for CPU with firmware revision r47 and above). See Also : READMODBUS , WRITEMODBUS , WRITEMB2 , STATUS(2) , SETSYSTEM 12.48 REFRESH Purpose : To Force immediate refresh of the physical inputs and outputs. This can be used afte r executing a SETBIT or CLRBIT command on an output[n] variable and to force the physical output to change immediately (subject to I/O refresh time delay). Otherwise, the physical output will only be updated during the normal refresh cycl e which will occur only at the end of every ladder logic scan. This is useful for situations that require immediately action such as shutting down a load during an emergency. This command is likely to be used mainly by an Interrupt CusFn. Comments : The REFRESH command takes approximately 0.5ms to complete on the Nano-10 and F-series PLCs, 1ms on the FMD series PLCs, and up to 2ms on the legacy M-series PLC. Note that if any expansion boards are connected to the FMD series or F-series PLCs, it could also take up to 2ms to complete. If used frequently, it could incr ease the program scan time significantly.

208. Chapter 11 11-5 b) Timers and Counters Present Values The present values (PV) of the 128 timers and 128 coun ters in the PLC can be accessed directly as system variables: timerPV[1] to timerPV[256], for timers' present value ctrPV[1] to ctrPV[256], for counters' present value c) DATE and TIME Variables The PLC's Real-Time-Clock (RTC) derive d date and time can be accessed via variables DATE[1] to DATE[3] and TIME[1] to TIME[3], resp ectively as shown in the following table: Date Time YEAR DATE[1] HOUR TIME[1] MONTH DATE[2] MINUTES TIME[2] DAY DATE[3] SECOND TIME[3] Day of Week DATE[4] DATE[1] : may contain four digits (e.g. 1998, 2003 etc). DATE[4] : 1 for Monday, 2 for Tuesday, .... 7 for Sunday. d) High Speed Counters The NANO-10, FMD series, and F-Series PLCs support High Speed Counters (HSC), which can be used to capture high freq uency incoming pulses from positional

39. Chapter 3 3-11 4. Click OK to complete the server login process. 5. Click ‘Yes’ to continue when prompted with the program transfer confirmation window: Note that the “Transfer Program to PLC” window also allows you to select: a) whether only the program file name should be sent with the program or b) if the entire directory path of where the program is saved should be sent For more information on this, refer to section 8.3 Controller Menu 6. Click ‘Start Transfer’ to initiate the actual program transfer if is displayed, which indicates program compilation was successful.

60. Chapter 4: Using TLServer 4-17 4.4.3 Setting Up TLServer As Email Master For Multiple PLCs on RS485 A PLC program raises an email request fl ag by setting the variable emEVENT[1] to a non negative value (see explanation on "Writing i-TRiLOGI Programs that Can Send Emails") whenever it needs to send an email. The TLServer, upon sensing that an email request flag ha s been raised, will extract the sender, recipient and message strings from the PL C's internal variables and send them out using the pre-defined SMTP outgoing mail server. A single TLServer can service the email requests for one or more (max. = 256) PLCs connected to it via RS232 (single PLC only) or RS485. The second half of the Email Setup scr een with the title "Legacy EMail Feature (from TLServer 1.0)" are related to this email method. The setup is as follow: PLC ID# column: For you to select PLCs with ID from 00-FF (256 in total) to set the email service period. Check Every (seconds) This allows you to define how often the TLServer should check the PLC (the email service period) for the state of the outgoing email request flag. Simply click on field next to the PLC ID# of interest to open up a text entry field (as shown in the figure for ID=02). Enter a non-zero value (in seconds) to define its email servicing period. Note: Both SMTP Server and email service period definitions will be saved to the hard disk when you exit TLServer program. They will be reloaded when you start TLServer again. Inactive PLC TLServer attempts to communicate with every PLC that has a non-zero email service period. However, if the PLC is inactive (e.g. It has not been turned ON or has been disconnected from the server ) the communication will fail. Since communication failure takes considerab le amount of CPU waiting time and could affect the normal communication wi th other active PLCs, inactive PLCs are internally marked by the TLServer (shown as message in the email setup dialog) and will not be che cked according to their defined service period to avoid repeated communication failure. However, TLServer will re-

71. Chapter 5 5-2 where you've installed i-TRiLOGI). At the directory, enter the following command line: C:\TRiLOGI\TL6> java -j ar -Duser.language=xx TL64.jar where xx is the ISO defined two char acters definition of the language code. E.g. "es" for Spanish, "ko" for Korean and "zh" for Chinese. NOTE: The main-window window size is "memorized" in the config.tl6 file. HELP!!! When running i-TRiLOGI, you can get on-li ne help any time by pressing the <F1>. A Help window will open to show you the typical key/mouse actions. You can also click on the <More Help> button to get context-sensitive help loaded into your web-browser. i-TRiLOGI version 6.x and up now uses the default browser of your computer to display help data If t he "config.tl6" line does not contain the path to an alternative browser in the: “Browser Path=” line (which it doesn't by default). However, If you do not want to use t he PCs default browser, then you'll need to use the "Notepad" program to manually edit the "config.tl6" file in the "C:\TRiLOGI\TL6\" directory. For example: If you wanted to use Internet Explorer as the browser for i-TRiLOGI, you will need to Modify the first line in "config.tl6" as follows: Browser Path=C:/Program Files/Internet Explorer/IEXPLORE.EXE to match the correct browser path info. T here is no need to configure the applet browser path since the TL6 Applet automa tically uses the same browser in which it was loaded to open the help files. Hence, the applet does not need to know the browser path at all. 5.2 Running TRiLOGI Applet Using Web Browser 1. Before you could run the TRiLOGI Applet in a web browser, make sure that the TLServer 3.0 is already running. 2. Next, start up your Inter net Browser. It should be ei ther an Internet Explorer version 5.0 or later, Netscape Navi gator/Communicator Version 4.5 or later or Mozilla Firefox version 1.5 or later.

98. Chapter 7 7-3 When you click on , the following window will appear You can select the bookmark No. either fr om the choice box or by clicking on the blue bookmarks: and . Then enter or edit the circuit # to associate with the selected bookmark. You can opti onally enter/edit a description for the bookmark to help you recall the purpose of that section of ladder circuit which the bookmark is associat ed with. Then click the button to update the circuit # and description at the corresponding bookmark location. In i-Trilogi version 6.2 and later the book mark you have created will be displayed in the corresponding ladder circuits. Ne w programs created will set all the bookmarks to a default value of 0 so that no bookmarks are displayed until they have been manually created. In i-Trilogi version 6.2 and later there is a feature that allows you to immediately go the last circuit that was selected. Th is is implemented by clicking on the button that is located beside the bookmark buttons, which are described above. Whether you move to a new circuit by using the "Goto Circuit" command or a bookmark or just by clicking on a circuit with the mouse, the "Last" button will remember your last circui t position. This also allows you to easily switch back and forth between two circui ts an unlimited number of times because if you don't select a new circuit af ter pressing the "Last" key, you will go back to the circuit you came from. Note: The bookmark definitions are saved along with the program body into the “.PC6” file, which means th at the bookmark that you defined for a particular program can be recalled later when you open its “.PC6” file.

166. Chapter 9 9-14 NOTE: The [dDIFU] function can now be implem ented as a single contact with the Rising-Edge contact that is triggered once every time a rising edge is sensed. More information on this new contact ca n be found in the Contacts section of the "Contacts and Coils" help page. 9.3.7 Custom Functions: [CusFn] and [dCusF] These two functions allow you to connec t a user-defined custom function (CusFn) to the ladder logic as if it is a relay coil. Custom functions are created using the integrated editor provided by i-TRiLOGI Version6.x. Please refer to TBASIC Reference manual for detailed desc riptions of custom function creation and deployment methods. 9.3.8 Master Reset An ON condition to this function clears all mailbox inputs, outputs, relays, timers and counter bits, resets all timers counters/sequencers to inactive state, and clears all latched relay bits. All integer variables will be cleared to zeros and all string variables will be assigned to empty string. 9.4 Using i-TRiLOGI Sequencers A sequencer is a highly convenient feature for programming machines or processes which operate in fixed sequenc es. These machines operate in fixed, clearly distinguishable step-by-step orde r, starting from an initial step and progressing to the final step and then rest art from the initial step again. At any

182. Chapter 10 10-10 10.2.7 Undo Changes Click this button to undo any changes yo u just made to the custom function. You may also use the <Ctrl-z> shortcut key to achieve the same. The “Undo” button (shown below) can be used to undo the last change to the text in the currently opened Custom Function. 10.2.8 Aborting Changes The “Abort” button can be used to abort any changes made to the currently opened Custom Function since it was op ened. The custom function editor will be closed when you abort an edit. Note: If you navigate away from the curr ently opened custom function, or if you exit a custom function by using the <ESC > key or by clicking the CusFn Editor- 3.jpg (1142 bytes) button in the top-right corner of the editor, then the content of the custom function currently in the ed itor will be updated into the internal

190. Chapter 10 10-18 CusFn is run when the condition which caus es the interrupt occurs. The response time to execution is very short comp ared to the scan time of the ladder program. There are several interrupt sources which can trigger a CusFn: a) Physical Interrupt inputs The NANO-10/FMD series/F-Series PLCs cont ain some hardware "Interrupt" inputs which, when enabled by the INTRDEF stat ement, will trigger a particular CusFn defined in the INTRDEF statement when the logic level at the interrupt pin changes state (either from OFF to ON or from ON to OFF). b) Periodic Timer Interrupt (PTI) The Periodic Timer Interrupt (PTI) lets yo u define a custom function that will be executed by the CPU precisely every x numb er of milliseconds (ms). The PTI runs independently of the ladder logic and its execution is therefore not affected by the total PLC program scan time. NOTE: The PTI is not available on the legacy T100MD/T100MX PLC c) Power Failure Interrupt (PFI) The NANO-10/FMD series/F-Series PLCs CPU has a built-in power failure sensing circuit that will call a custom function when it detects an impending power failure. This allows you to perform such critical function such as saving critical data to the PLC’s non-volatile memory just before power failure. NOTE: The PFI is not available on the legacy T100MD/T100MX PLC d) High Speed Counters (HSC) Reach Target Count These PLCs also contain some "High Speed Counter" inputs which, when enabled by the HSCDEF statement, will tr igger a particular CusFn defined in the HSCDEF statement when the counter reaches a preset target count value. This enables the CPU to carry out immediate action such as stopping a motor or performing some computation. 10.5 Simulation & Examination of TBASIC Variables

218. Chapter 12 12-2 Comments : B should contain the value 83 (which is ASCII value of 'S'). If n is less than 1 or greater than string length, ASC(x$, n) returns a 0. See Also : CHR$(n) 12.4 CALL n Purpose : To call another Custom Function CusFn #n as subroutine. When the called function returns, execution will continue from the following statement. n mu st be either an integer constant between 1 and 256, or the label name of the Custom Function defined in the Custom Function table. Examples : IF B > 5 THEN CALL 8 : ENDIF CALL Addition “Addition” must be a defined name. See Also : RETURN 12.5 CHR$(n) Purpose : To convert a number n into its corresponding ASCII character. n must be a numeric constant (0 to 255) Examples : C$ = "This is Message #" + CHR$(&H35) Comments : C$ should contain: "This is Message #5", since CHR$(&H35) returns the character '5'. In TL6 you can also use “Escape” sequence to represent non-printable ASCII characterr E.g. "/0D” to represent CR character. See Also : ASC( ) 12.6 CLRBIT v, n Purpose : To clear the Bit #n of the integer variable v to '0'. n is an integer constant or variable of value between 0 and 15. v may be any integer variable or a system variable such as relay[n], output[n], etc. If v is a 32-bit integer, CLRBIT will only operate on the lower16 bits.

254. Chapter 12 12-38 Examples : save_EEP relay[1],100 save_EEP8 relay[1],100 save_EEP16 relay[1],100 save_EEP32 relay[1],100 See Also : LOAD_EEP( ) , GETHIGH16( ) , SETHIGH16 , LOAD_EEP$( ) and SAVE_EEP$ 12.55 SAVE_EEP$ strdata, addr Note : Applicable to all Nano-10, FMD Series, and F-series, but only to the legacy T100MD/MX PLC with firmware r44 or higher. Purpose : To store a string strdat a in the user’s definable EEPROM address addr for non-volatile storage. Parameters : strdata - may be any string constant or string variable. addr - FRAM/EEPROM address (1,2,3...). Please refer to your PLC’s reference manual for the upper limit of FRAM/EEPROM space. Implementation: Save_EEP allows you to save “strings” into the non-volatile data area of the PLC, which could be FRAM, FLASH, or EEPROM (legacy M-series PLCs only). This data space is divided into 40-byte chunks for string storage. I.e. regardless of the length of the string, each string storage location will occupy a fixed 40-character l ength. Hence if “stringdata” parameter is longer 40 characters, then only the first 40 characters will be stored in the memory space and the remaining characters will be discarded. The string and integer data actually share the same pool of data space. However, the string spaces are allocated from the top of the data space downward, while the integer spaces are allocated from the bottom of the data space and grow upward. This im plementation allows say both SAVE_EEP n, 1 and SAVE_EEP$ x$, 1 to be executed in the same program without the string and integer data writing over each other space.

260. Chapter 12 12-44 settings. Consult chapter 1 of yo ur PLCs reference manual for more details on regaining serial communication. Examples : SETBAUD 3,3 ‘ Set serial port #3 to 9600. 12.62 SETBIT v,n Purpose : To set the bit #n of the in teger variable v to '1'. v may be any integer variable or a system variable such as relay[n], output[n], etc. The range of n depends on the PLC firmware version, as follow: PLC Firmware Before r78 r78 or later n 0 to 15 0 to 31 n is an integer constant or variable of value between 0 and 15 or between 0 and 31. Following digital electronics convention, bit 0 refers to the least significant bit (rightmost bit) and bit 15 the most signific ant bit (leftmost bit) of the 16- bit variable and bit 31 is the most significant bit of a 32-bit integer variable. For older PLC firmware (befor e r78), SETBIT only works on the lower 16 bits. Please refer to page 10-4 in “C hapter 10: TBASIC Statements, Functions, Operators and Va riables” for the mapping between I/O bits and the variables. Examples : SETBIT output[2],11 Comments : output #28 will be turned ON. (Output channel #2 bit #11 = Output #17 +11 = 28) See Also : CLRBIT , TESTBIT( )

267. Chapter 12 12-51 executed and you can regain control of the PLC using i- TRiLOGI. 12.71 SETPWM n, x, y Purpose : To set channel #n of t he PLC's Pulse-Width Modulation (PWM) output with duty cycle repres ented by (x/100 %) and at a frequency (in Hz) given by parameter y. Parameters : n = PWM channel. Range = 1 to 8. Once set, the PWM channel will latch the set value until the next SETPWM statement on the same channel is executed. x = Duty Cycle. Range = 0 to 10000. If x is more than 10000, the duty cycle will be set to 100% y = Frequency. Range = 0 to 50000. If y is more than 50000, the frequency will be set to 50khz Examples : SETPWM 1, 4995, 2000 Comments : PWM channel #1 will be set to operate at 49.95% duty cycle for PWM that can resolve up to 0.01%. The actual resolution will depend on the PLC's PWM resolution. The PWM frequency is set to 2000 Hz or nearest. For a 10-bit PWM the best reso lution is about 1/1024 = 0.1 %. This means that in the above example the PWM will be rounded to 50%. Please check t he target PLC's manual for the actual resolution. 12.72 SETSYSTEM n, data Purpose : Allow changing of cert ain default system’s parameters. Currently only the following data are defined. More parameters may be defined in future. Some commands are specific to a PLC model and these will be mentioned in the relevant section of the hardware manual. n data Description

292. Chapter 12 12-76 DeviceID = Device ID of the MODBUS device. Range = 1 to 255 Address = Zero-offset address of the holding register in the MODBUS device. data = the 16-bit data to be written to the MODBUS device Example : WRITEMODBUS 3, 8, 1000, 1234 The data 1234 will be written to the MODBUS ASCII device with ID=08 at the holding re gister offset address 1000 (in MODBUS convention this refer to holding register #41001). WRITEMODBUS 13, 8, 1000, 5678 The data 5678 will be written to the MODBUS RTU device with ID=08 at the holding register offset address. See Also : READMODBUS( ) , STATUS(2) , NETCMD$( ) 12.93 WRITEMB2 ch, ID, addr, var, count Note : Applicable to all Nano-10, FMD Series, and F-series, but only to the legacy T100MD/MX PLC with firmware r44 or higher Purpose : Automatically write the mu ltiple words of 16-bit data to a MODBUS device using the MODBUS RTU/ASCII protocol. It is essentially the WRITEMODBUS command except multiple words can be sent. Comments : The command automaticall y checks the response string received from the slave device for the correct LRC and the slave address. The status of th e operation can be checked by the user program by testing the STATUS(2) function, which will return a ‘1’ for successful command and a ‘0’ if there is any error or if the slave device is not present. Parameters : ch - PLC COMM port number. Range = 1-8 for MODBUS ASCII

303. Appendix 1 A1-9 The online monitoring window should open immediately if you are still connected to the server. If not, then follow steps b-d from the serial Program Transfer section above to login to TLServer, or the Ethernet Program Transfer section below to login to FServer (PLC). The above monitoring window will appear after successful login. A1.2 Part 2: Ethernet Communication Setup Guide 1) NETWORK WIRING Below is an example of the most comm on network setup, which assumes the default PLC IP address (192.168.1.5) is able to work on your network. If this IP will not work, then follow the serial port setup in structions in part 1 of this guide and

326. Appendix 4 A4-2 Modem 2: The modem to be attached to the PLC (modem2) must be an external modem with an RS232 connection port. Since modem are DCE type device, they most likely come with a female type DB25 or DB9 socket meant for plugging into the PC’s RS232 port. Since the PLC’s host link port is also a female DB9, we need to construct a DB9-male -to-DB25-male cable or DB9-male-to-DB9- male cable to link the PLC to the modem, as follow: A4.2 Communication Speed When communicating via mo dems, there are two different definitions of communication speeds that you should be aware of: • The "DTE Speed" or "line rate" is t he serial communication speed between the modem and the device connected to its RS232 port. Most modems

204. Chapter 11 11-1 11 TBASIC STATEMENTS, FUNCTIONS, OPERATORS AND VARIABLES 11.1 What are TBASIC Statement and Functions? 11.1.1 STATEMENT A STATEMENT is a group of keywords used by TBASIC to perfor m certain action. A statement may take 0,1,2 or more arguments. The following are some TBASIC statements: PRINT, LET, IF, WHILE, SETLED ...etc. 11.1.2 FUNCTION A FUNCTION acts on its supplied argum ents and return a value. The returned value may be an integer or a string. A function can usually be embedded within an expression as if it is a variable or a constant, since its content will be evaluated before being used in the expression. e.g. A$ = "Total is $"+STR$(B+C) STR$(n) is a function which returns a string and therefore can be used directly in the above string assignment statement. The most distinguishable feature of a FUNCTION is that its arguments are enclosed within parenthesis "(" and ")". e.g. ABS(n), ADC(n), MID$(A$,n,m), STRCMP(A$,B$). Note: Statements or functions and their arguments are NOT ca se-sensitive. This means that commands such as PRINT and PriNt are identical. However, for clarity seek we use a mix of upper and lower case characters in this manual. 11.1.3 DELIMITER A TBASIC program consists of many st atements. Each statements are usually separated by a different line. The new li ne therefore acts as a "delimiter" which separate one statement from an other. Some statements such as IF..THEN..ELSE..ENDIF span multiple st atements and should be separated by proper delimiters.

41. Chapter 3 3-13 executes a ' RESET ' or ' SETSYSTEM 252,0 ' command first. This is necessary whether or not any FRAM-R TC module is installed . The program will still run normally other than that. If you click ‘Reboot’, the PLC will be hard reset (CPU is power cycled). This is not used for normal program transfer and is only necessary if there is a specific purpose for cycling PLC CPU po wer. Just as for a Reset, any timer and counter set values would be permanently stored in the PLC. The program transfer is now complete and online monitoring can be performed. Online Monitoring a) Select “On-Line Monitoring” from the “Controller” m enu (or press CTRL + M on the keyboard). b) The online monitoring window shou ld open immediately if you are still connected to the server.

155. Chapter 9 9-3 The above example may be simple but it illustrates the basic concept of logical AND and OR very clearly. "controlSW1" and "controlSW2" are connected in series and both must be TRUE for the outcome to be TRUE. Hence, this is a logical AND connection. On the other hand, either of the two parallel branches may be used to conduct current and, hence, this is a logical OR connection. Another type of contact, available for all of the Ethernet PLCs only, is the Rising- Edge contact, which looks like this: in the ladder logic toolbar and like this: when placed in a ladder logic circuit. This type of contact will detect a change of status from off to on and then send a single pulse out (one shot). This contact can be used for any physical input or output or any internal bits (relay, counter, timer). In the case of physical input and output rising-edge contacts, a rising edge will be detected if the I/O has changed from off to on from one I/O scan to another (any I/O status changes that happen during a ladder logic scan won’t matter for physical I/O). In t he case of the internal bit rising-edge contacts, a rising edge will be detected if the internal bit has changed from off to on from one ladder logic scan to another (any internal bit status changes that happen during an I/O scan won’t matter for internal bits). Here are some examples of this for the physical I/O: Ex1 . In the circuit shown below, if Input1 is off for an I/O scan and then on for the next I/O scan, a single pulse (one shot) wi ll be sent to Output1 and Output1 will be turned on for one program scan time (turned off on the next I/O scan). On the same I/O scan that Output1 is turned off and all following I/O scans, whether Input1 is still on or has been turned off, a rising edge will not have been detected and Output1 will remain off. Fo r a new rising edge to be detected, Input1 must be scanned as off first and then scanned as on in a following I/O scan. Ex2. In the circuit below, when Input1 goes from the off status to on status (as described previously), a single pulse will be sent to a [Latch] function that will latch Output1 to the on status. The actual Latch function will only be activated for a single scan time (just as Output1 wa s in the previous ex ample), but it will permanently latch Output1 to on until Output1 is unlatche d using the [Clear] function. This way Output1 will remain on even though Input1 has only sent a single pulse and Output1 will not be affected by any further rising-edge detections from Input1 (can only be latched once until it is unlatched).

248. Chapter 12 12-32 Special : This command by default uses MODBUS function 03 to perform the read, which means th at it is designed to read from holding register addresses (4-xxxx). You can force it to change to using function 04 in order to read from addresses 3-xxxx by executing SETSYSTEM 6,4 (only for CPU with firmware revision r47 and above). See Also : READMB2 , WRITEMB2 , WRITEMODBUS , STATUS(2) , NETCMD$( ) , SETSYSTEM 12.47 READMB2 ch, ID, addr, var, count Note : Applicable to all Nano-10, FMD Series, and F-series, but only to the legacy T100MD/MX PLC with firmware r44 or higher Purpose : Think of this as the mu lti-word version of READMODBUS command. Unlike the READM ODBUS command which is a function that returns a single 16-bit word, this command is implemented as a statement so that multiple words of data can be stored into the PLC internal memory . Parameters : ch - PLC COMM port number (1to 8 using Modbus ASCII or 11to 18 using Modbus RTU). ID - Device ID of the MODBUS slave device (1 to 255) addr - Zero-offset address of the holding register in the MODBUS slave device starting from 0 = 40001. var - the starting variable in the master for storing the returned data. (may be a DM or any system variable) count - number of variables to read (max. =16). Example : READMB2 3,5,101,DM[10],8 Comments : The PLC will use MODBUS ASCII protocol, via its Comm port #3, to query the slave MODBUS device with ID = 05 and ask

283. Chapter 12 12-67 Example: If 2,345 bytes have been uploaded to the server and the transfer has ended => A = STATUS(20) returns –2345 to A. See the Extended File System chapter in the PLC user manual for more information. Note: only for PLCs with firmware r77 or above 21 Return CPU Counter Value Can be used to measure execution time. This function returns the 32-bit value of a 10MHz free running counter in the CPU. The difference between the values from two STATUS(21) gives the elapse time of a process in 0.1us. E.g: A = STATUS(21) CALL [somefunction] B = STATUS(21) - A B is the execution time of [somefunction] in 0.1 microseconds. (i.e. if B = 10000 => 1 ms) Note: only for PLCs with firmware r78 or above 12.76 STEPCOUNT (ch) Purpose : While the stepper motor controller is sending out pulses, this function can be used to mo nitor the number of stepper pulses sent to the Stepper Motor Channel #ch since the execution of the last “STEPMOVE” command. Hence this function returns the relative number of step moves. This function can also be used to “measure” the physical size of a part if we use the stepper motor to drive a sensor and use the STEPSTOP command and the interrupt input to halt the stepper motor when the edges are detected. The physical size is then computed using the number of steps the stepper motor travels from one edge to another edge. The center position can be easily determined using such data too.

287. Chapter 12 12-71 12.81 STEPSPEED ch, pps, acc Purpose : To set the speed pps and acceleration/retardation acc parameters for the PLC's stepper motor motion controller (pulse-generator) channel #ch. Parameters : ch = Channel. Range = 1 to 8. pps = Speed. Range = 1 to 10000. Set the target no. of pulses pe r second (pps) output by the pulse generator. Acc = Acceleration Steps. Range = 1 to 2 32 . The acceleration ‘acc’ determines the total number of steps taken to reach full accelerati on from standstill and the number of steps from full speed to a complete stop. Comments : The stepper motor calculates and performs the speed trajectory according to these parameters when the command STEPMOVE is executed. STEPSPEED command should be executed at least once before executing any subsequent STEPMOVE command to control the pulse generation. T he defined parameters will be remembered until another STEP SPEED statement operating on the same stepper channel is executed again. Examples : STEPSPEED 2,2000,20 The PLC's Stepper motor cont roller channel #2 is configured to send out pulses at 2000 puls es per second when STEPMOVE instruction is executed. It follows a linear acceleration trajectory which takes 20 pulses to reach the full speed of 2000 pps. This is equivalent to an acceleration of: a = = = 100,000 pulse/s2 12.82 STEPSTOP ch

35. Chapter 3 3-7 test communication. If you have only one PLC connected to your TLServer computer, then you can test the communication now using the following command string: Command String : IR* Response String : IR01* The response string tells you that the ID a ddress of this single PLC is 01, which is default. If the ID was changed, then it will be shown in place of 01. If you get the message (Warning: No Response From PLC!) , then communication is not setup properly . First repeat the steps from PLC connection to TLServer setup and if ther e is still no response, refer to the TROUBLESHOOTING SERIAL COMMUNICATION Appendix at the end of this document. If you received the correct response, then setup is complete and communication is confirmed, so you ca n proceed to the next section to get communicating from TRiLOGI. 3.2.2 TRiLOGI Communication TRiLOGI is the client program that is used as the PLC programming environment and to perform the two main types of communication from TRiLOGI:

54. Chapter 4: Using TLServer 4-11 not want to do that. It depends on w hether you are installing TLServer on a corporate intranet or on the public Inte rnet and whether the client (TRiLOGI) is to access TLServer within the intranet en vironment or from the public Internet. Please read Appendix 2: “PLC & PC Har dware Setup and Configuration” for an explanation of how to use the port number properly. Ports, or addresses within a comput er, are used to enable communication between programs. Port addresses are 16-bit addresses that are usually associated with a particular application protocol. An application server, such as a Web server or an FTP server, listens on a particular port for service requests, performs whatever service is requested of it, and returns information to the port used by the application program requesting the service. Popular Internet application protocols ar e associated with well-known ports. The server programs that implement these pr otocols listen on these ports for service requests. The well-known ports for some common Internet application protocols are shown below: Port Protocol 21 File transfer protocol 23 Telnet protocol 25 Simple mail transfer protocol 80 Hypertext transfer protocol 4.4 Setup Emails 4.4.1 Introduction Before the Ethernet port was integrated into the newer Super PLCs such as the Nano-10, FMD and F-series, TRi PLCs can on ly use the TLServer as TCP/IP gateway to perform network related functions, including sending of emails. For newer PLCs with built-in Ethernet, in many ca ses the PLC can be setup to send email directly without relying on the TLServer. Please see the following FAQ posting for a description of all the current email methods: http://www.tri-plc.com/faqans5.htm#ans61 However, TLServer can still be very us eful as email helper in the following situations:

55. Chapter 4: Using TLServer 4-12 1. There is no Ethernet cable availabl e to the PLC but the PLC are networked via RS485 to a PC. 2. The PLCs are not permitted to make TCP connection directly to SMTP server residing outside of the LAN. 3. The SMTP server requires authentica tion to send email that the PLC cannot handle natively. The following describe in details the seve ral ways in which the TLServer can be used to help the PLC send out emails. Email Method 1 - Using TLServer as Email Master The TLServer supports a legacy email feature (carried over since version 1.0) where the TLServer act as a master to a bunch of PLCs connected together via their RS485 port. TLServer can be configured to scan the internal variables of any of the up to 256 PLCs ID connected to it to determine if any of these PLCs has a request for the TLServer to send out email. If so the TLServer will then retrieve the email data from the relevant PLC, construc ts a complete email and send it out. Click here for more details. Email Method 2 - Using TLServer as Email Slave In this setup, the TLServer will monitor the data it receives via its serial port for a special <EMAIL> tag, which triggers a se quence of actions w here it receive the sender, recipient, subject and mail content via the serial port. When all the data have been received the TLServer will connect to the SMTP server and send out the email. In this setup only 1 PLC may be connected to the TLServer to send out emails since it is a one-to-one intera ction between the PLC and the TLServer program. For more details on this email method, please view the " File and Email Services " section. Email Method 3 - Using TLServer as Email Relay Server - NEW! As you will see shortly, since version 3.16, the TLServer can be setup to work with both SMTP servers that require authentic ation and those that don't. However, the default email function on the Nano -10, FMD and F-series PLCs does not support account authentication to communicate with the external SMTP server. If the PLC is connecting to the SMTP serv er provided by the ISP then in many cases authentication is not needed sinc e the ISP will only allows connection from IP address that belongs to its subscribers. However, if your SMTP Server is not supp lied by the ISP of the network to which the PLC connects, then most likely authent ication will be required. In such a

96. Chapter 7 7-1 7 I-TRILOGI LADDER LOGIC EDITOR i-TRiLOGI's ladder logic editor window lies between the main menu bar along the top of the screen and the help me ssage line along the bottom of the screen. The cursor will a ppear in the window whenever you are in the logic editor. The ladder logic editor comprise s two modes: the browse mode and the circuit editing mode. We shall explain the operation of both modes. 7.1 The Browse Mode You are normally in the browser mode when you start up the program. The browse mode allows you to manipulate t he whole ladder logic circuit as a single entity: you can view any circuit, make copi es of it, move it to another location or delete it entirely. Each complete ladder logic "circuit" is given a circuit number. You should see a small red co lor marker showing you the currently selected circuit. The circuit number of t he selected circuit is shown on the upper status line as "Circuit # xxx ". 7.1.1 Mouse Actions Since i-TRiLOGI Version 6 runs under wi ndowing environment, all usual mouse action applies. You can grab the vertic al scroll bar to scroll to your desired circuit and click on it to select it. Doub le click on a circuit enters the Circuit Editing Mode which will be described later. 7.1.2 Keyboard Actions The functions of various keys in the browse mode are explained below: 1. <Spacebar> - Allows you to enter circuit editing mode for the currently selected circuit. If the selected ci rcuit is a comment ci rcuit, the comment editor will be opened automatically. 2. <F1> - Activates the context-sensitive help function to display on-line help. 3. <F2> - Opens the I/O Table to create the I/O Label Names 4. <F3> - Turns ON/OFF display of the I/ O type and the physical I/O number for ladder logic contacts on the screen (The physical I/O number is now linked to the labelname). All ladder logic cont act symbols are normally identified by their label names. However, you can also display an optional small

100. Chapter 7 7-5 7.2.2 Insert Circuit This command enables you to insert a new circuit just be fore the currently selected circuit. The curr ent circuit number will be increased by one while the new circuit will assume the current circui t number. You will be placed in the circuit editing mode for immediate circuit creation. 7.2.3 Move Circuit You can rearrange the order of the circuits by using this command. Select the circuit you wish to move and execute the "Move Circuit" command, then select a destination circuit location and press <Enter>. The selected circuit will be moved to the new location before the destination circuit. Note that if you wish to move a block of circuits to a new location, you may find it more productive to use the "Cut Circuit" and "Paste Circuit" commands in the "Edit" menu. 7.2.4 Append Circuit Execute this to add a new circuit to the ladder logic program. This new addition will be positioned immediately after the last circuit in the entire program. 7.2.5 Delete Circuit This command allows you to delete the one or more circuits. You will be prompted to enter the range of circuits that you wish to delete. Please note that you can't UNDO a delete circuit operation.

219. Chapter 12 12-3 Following digital electronics convention, bit 0 refers to the least significant bit (right most bit) and bit 15 the most significant bit (left most bit) of the 16-bit integer variable. Examples : CLRBIT output[2],11 Comments : Physical output #28 will be turned OFF. (Output channel #2 bit #11 = Output #17 +11 = 28) See Also : SETBIT , TESTBIT , SETIO , CLRIO , TOGGLEIO & TESTIO 12.7 CLRIO labelname SETIO labelname TOGGLEIO labelname TESTIO (labelname) Purpose : Manipulate the logic states of any input, output, relay, timer or counter contact bit within a CusFn. The labelname refers to the label names defined in the in put, output, relay, timer or counter tables. SETIO set a bit to ON, CLRIO clear the bit to OFF, and TOGGLEIO flip the current logic state of that I/O bit. TESTIO function returns a 1 if the bit is ON and a 0 if the bit is OFF. Examples : SETIO alarm IF TESTIO(alarm) THEN ... ELSE ...ENDIF Comments : This function offers a more efficient way of manipulating the I/O bits compared to the SE TBIT and CLRBIT function. However, SETBIT and CLRBIT functions have the advantage that they can use variables to indicate the index and bit position of the bit to be affe cted, whereas the I/O bit that affected by the commands here are fixed during compile time. Note that output bit changed in custom function will only be updated at the physical output at the end of the ladder logic scan unless a “REFRESH” command is being executed. See Also : SETBIT , CLRBIT

252. Chapter 12 12-36 Bits are shifted from the upper channel towards the lower channel. Bit #0 of Relay[4] will be shifted into Bit #15 of Relay[3] and so on. Bit #0 of t he lowest channel Relay[2] will be lost. See Also : LSHIFT 12.54 SAVE_EEP data, addr SAVE_EEP8 data, addr8 SAVE_EEP16 data, addr16 SAVE_EEP32 data, addr32 Note : SAVE_EEP8, SAVE_EEP16, and SAVE_EEP32 are only available on PLCs with firmware >= r78. SAVE_EEP is equivalent to SAVE_EEP16 and is available on all firmware versions. Purpose : To store an 8-bit, or 16- bit, or 32-bit integer in the user’s definable EEPROM/FRAM space at address addr8 /addr16/addr32 for non-volatile storage. Comments : SAVE_EEP8 If you attempt to save a 32-bit data, only the lower 8 bits will be saved. SAVE_EEP / SAVE_EEP16 To save the entire 32 bits of data, a) If your PLC firmware is < r78, then save the upper 16-bit using the GETHIGH16( ) function and the lower 16-bit directly in two separate locations. b) If your PLC firmware is >= r78, use SAVE_EEP32 command to save 32-bit vari able to the EEPROM/FRAM

297. Appendix 1 A1-3 Click on to open the serial port setup window (below screenshot). Once TLServer is configured , leave it running because it is needed to communicate with the PLC. If no settings have been changed in t he PLC, then the default baud settings shown above can be used. You will only need to select the correct COM port from the Port Name: field. Select the port your USB adapter is in stalled on. If you are unsure, check the device manager in your PCs contro l panel. You can see from the below screenshot that the Prolific USB adapter (f or RS232) is installed on COM6, so you would select COM6 from the Port Name field. Similarly, would select COM6 from the Port Name field for the Silicon Labs USB adapter (RS485).

62. Chapter 4: Using TLServer 4-19 The maximum number of lines in your em ail body is limited by the number of string variables D$ to Z$ (23 in total) available in the Nano-10, FMD series, and F- Series PLCs. For example, if the PLC needs to send em ail to trilogi@yahoo. com with a 1-line greeting, then the program needs to activa te a custom function that contains the following statements: A$ = "Demo1@PLC" ' sender B$ = "trilogi@yahoo.com" ' recipient C$ = "This is an email demonstration" ' subject D$ = "The time is"+STR$(TIM E[1])+":"+STR$(TIME[2])+". How are you doing ? " ' Message body emEvent[1] = 1 You must also setup the email service period (say every 10 second) in the "Setup Emails" screen for this PLC. When the TLServer scans the PLC and found that its emEvent[1] is set to 1, it will extract the headers and message body from the PLC's string variables. Only A$ to D$ will be extracted in this example since the message contains one line of body text only, as indicated in emEvent[1]). TLServer will then contact the SMTP server to send out the email. In addition, after processing the email re quest, the TLServer will set the emEvent[1] variable to a value of "-1" (no email). Hence ther e is no need for the i-TRiLOGI program to worry about clearing the email request flag after the email has been sent. In addition, this provides a way for the PL C program to know whether the TLServer is functioning properly and whether the email request has already been processed. However, do take note that even if the emEvent[1] has been reset it does not guarantee that the email has been correctly dispatched to the recipient. Success of emailing is subject to the prop er configuration of the TLServer, the network quality and availability of the SMTP server at the moment when TLServer tries to send out the email. For urgent situations you may consider sending out multiple emails periodically until the user has attended to the machine. 4.5 File and Email Services Starting from version 2.0, the TLServer provides a number of “File and Email Services” to the PLCs via the serial comm port. TRi Ethernet PLCs such as Nano-

160. Chapter 9 9-8 This special bit will only be turned ON in the very first scan time of the ladder program. After that it will be permanently tu rned OFF. This is useful if you need to initialize certain conditions at the beginn ing. When the program is transferred to the PLC, this bit will only be ON when the PLC is first powered up or after it has been reset. 9.2.5 Real Time Clock Error - RTC.Err FMD and Nano-10 PLC This bit is turned ON if an Nano-10 or FMD PLC does not have one of the following installed: FRAM-RTC, FRAM-RTC -0, FRAM-RTC-256 or I2C-FRAM-RTC and the clock has been reset due to power failure or watchdog timer reset. This gives warning to applications that require a correct real world time (such as scheduled ON/OFF operation) that the cl ock data is incorrect, hence enabling corrective action to be taken. F-Series PLC Since the F-Series PLCs do not use t he MX-RTC and instead have an on-board batter-backed RTC, the RTC Error event occurs if the RTC is corrupted or damaged (see the F-Series User Manual - section 12.8 for more detail) or if the battery is not installed. The special bit is called RTC.Err and can be obtained from the “Special Bits” I/O Table. The RT C.Err contact can be used to activate an alarm of some kind. M-Series PLC (Legacy) This bit is turned ON if the M-series PLC does not have battery-backed MX-RTC option and the clock has been reset due to power failure or watchdog timer reset. This gives warning to applications that require a correct real world time (such as scheduled ON/OFF operation) th at the clock data is incorrect, hence enabling corrective action to be taken. 9.3 Special Functions During ladder circuit editin g, when you click on the or icon to create a special function coil, a specia l function menu will pop up as shown below:

198. Chapter 10 10-26 10.7.3 Debugging Using Breakpoint on Simulator With a break point set in the custom fu nction and if you run the program using the simulator, when the simulator runs to the line where a breakpoint is set the program will pause and the custom functi on where the breakpoint is defined will be opened with the breakpoint line highlighted as shown in the following picture: At this point you can examine the variable data by clicking on the "View Var." button, which will open up the "View Va riable" screen. You can release the program from its PAUSE state by either cl icking on the "Continue" button or by clicking on the "Pause" button on the on-l ine monitoring screen. The program will continue execution until it hits the next breakpoint. Note that when the program is halted at a breakpoint you can defi ne more breakpoints so as to track the program execution. You can remove old brea kpoint at any time if you run out of the maximum 8 breakpoints limit. 10.7.4 Debugging Using Breakpoints on PLC Notice the checkbox below the "Toggle Breakpoint" button ? If you wish to halt the actual PLC (not the simulator) when the program runs to

263. Chapter 12 12-47 to the SSR to turn it on at 78 x (internal timer tick of 53 microsecond per unit) = 0.00413second from the last zero crossing. For a 60Hz AC this will occur at about 90 degree phase angle since the time duration of half a 60Hz wave = 1/60/2 = 0.00833 seconds. 12.66 SETHIGH16 v, data Purpose : To assign the upper 16-bi t of a 32-bit intege r variable v to data. The lower 16-bit of v is un affected. This can be used to construct the value of a 32-bit integer data using two 16-bit data obtained from either the EEPROM or the DM[n]. Examples : A = DM[2] SETHIGH16 A,DM[1] Comments : If you are constructing the value of a 32-bit variable from two 16-bit data, then SETHIGH16 should be executed only after the lower 16-bit has been assigned to the 32-bit variable, as shown in the above example. If you were to execute A = DM[2] after the SETHIGH16 A, DM[1] statement, the SETHIGH16 operation would have been lost since the assignment statement itself overwrites all previous operation (including SETHIGH16) on variable A. See Also : GETHIGH16( ) 12.67 SETIO labelname Note : -- Please refer to the definition of CLRIO command 12.68 SETLCD n, offset, x$ Purpose : To display the string expr ession x$ on Line #n on built-in alphanumeric Liquid Crystal Display (LCD) or compatible Vacuum Fluorescent Display (VFD). Comments : x$ may be formed by conc atenation of various strings using the ‘+’ operator (e.g. “Temp =”+STR$(A,3)+CHR$(223)+” C”).

269. Chapter 12 12-53 1 d higher) For T100MD+ and T100MX+ data (d) is applied to all 3 COMM ports simultaneously and can be any value from 0 to 255 e.g. SETSYSTEM 1, 3 The PLC will wait 3 x 150ms = 450ms for a valid response from the slave controller on all 3 serial ports. 2 2 dd dd dd dd d 12.72.2 Number of Com Retries # of retries if NETCMD$, READMODBUS, WRITEMODBUS, READMB2 or WRITEMB2 failed to get a valid response from slave controller. For Nano-10, FMD and F-series PLCs SETSYSTEM 2, data affects the 4 COMM port individually (COMM4 is Ethernet client connection) , where bit 0 & 1 for COMM1, bit 2 & 3 for CO MM2 , bit 4&5 for COMM3 and bit 6&7 for COMM4. By default data is set to &HAA (binary 10 10 10 10). This means 2 re-tries (a total of 3 tries) for all 4 COMM ports. data : dd dd dd dd Comm port : 4 3 2 1 Where dd = 00, 01, 10, or 11 (maximum = 3 re-try) In order to change the number of retries for COMM2 to 1 retry you have to set the bit 2 & 3 of data. E.g SETSYSTEM 2, &HA5 'binary 10 10 01 10 The above example set COMM2 to 1 retry and the other 3 ports are 2 retries. For T100MD+ and T100MX+

33. Chapter 3 3-5 3.2 Software Interface The first section will describe TLServer setup, which is used for serial port communication only. If you will be connec ting via Ethernet, you can skip the TLServer section and go straight to TRiLOGI Communication . 3.2.1 TLServer Setup TLServer is the server program that pr ovides serial connection to the PLC and TCP/IP connection to the TRiLOGI programm ing software. It is described in more detail in Chapter 2 Introduction to i-TRiLOGI Client/Server Architecture . TLServer is not needed for TCP/IP communi cation to the PLCs Ethernet port, only for serial communication . 1) First you will need to start TLServer , which can be done from the start menu or quick launch. See section 1.5 Run TRiLOGI and TLServer for more details on starting TLServer. The below-left window will open:

40. Chapter 3 3-12 Program compilation occurs automatica lly and you would not be able to proceed with the transfer if it failed. In that case, the general location of the error will be displayed with a description to help with troubleshooting. 7. Wait while the program transfer takes place (below-left screenshot). 8. Click ‘Reset’ when the program transfer is complete (above-right screenshot). IMPORTANT: (For Nano-10, FMD88-10, and FM D1616-10 PLCs) If your program is using any timers or counters, you must click ' Reset ' when the program transfer is complete so that the set values are properly stored to FLASH memory in the PLC. If you click on 'Close', timer and counter set values would not be retained and would be lost when PLC power is tu rned off or cycled unless the program

58. Chapter 4: Using TLServer 4-15 provide the correct Auth. Username an d Auth. Password. If you are unsure about this, then you should contact your ISP or System Administrator for help. Auth. Username: If Authentication is required , you will need to provide the correct Username. This is provided by yo ur ISP and you should contact your ISP or System Administrator if you don't know what it is or if you don't know if you need it. Auth. Password: If Authentication is required , you will need to provide the correct Password. This is provided by your ISP and you should contact your ISP or System Administrator if you don't know what it is or if you don't know if you need it. Port # to Relay PLC Email: If the TLServer is setup to be the email relay server for the PLCs, TLServer will be listening on this port for a SMTP connection from the PLC. The default port number is 9025. Th is port number is to be used as the SMTP port # on the PLC's "Ethernet & AD C Configuration" screen in order for the TLServer to relay the email content to the actual SMTP server that requires authentication. Please see Em ail Method 3 -Using TLServ er as Email Relay Server for description onon this topic) Important: your PC's firewall must be setup to allow connection to this port from other devices on your network in order for TLServer to work as an email relay server for the PLC. E.g. If the PC running the TLServer has IP address = 192.168.1.100, and the "Port # to Relay PLC Email" is set to 9025, then if the PLC wants to use TLServer as a SMTP relay server, it should configure its Ethernet port settings as shown below: You can test your email configuration by clicking the button once you have entered all the correct sett ings. Once you click the "E mail Test" button TLServer will initiate the sending of a test email us ing the Mail Server you specified. A new

122. Chapter 8 8-16 executes a ' RESET ' or ' SETSYSTEM 252,0 ' command first. This is necessary whether or not any FRAM-RTC module is installed . Refer to the Program Transfer section for procedure details 8.3.5 Transfer .CO5 File To PLC This new command is added from i-TRiLOGI version 6.41 onwards. It lets you transfer a file that has been saved previous ly to the hard disk using the "File -> Write Compiled Code To Disk" function under the "File" Menu. Using this function you can send compiled code to other users to be transferred into the PLC using a licensed copy of i-TRiLOGI v6.41 and above, but without revealing your source code. To ensure th at the file is not corrupted when you email to others, try to compress it using a Zip or Rar software. 8.3.6 Open Matching Source File You can use this command to query the connected PLC for the filename of the last i-TRiLOGI program transferred to it an d it will attempt to match it to a file stored in the log-in user's directory at TLServ er or on the PC's hard disk. If the file is found, it will be opened. Otherwise it will re port that the file is not found. Note that this command only opens the source file based on file name matching. It does not verify whether the file has been mo dified. It is the user's responsibility to ensure that the file stored in the server is the same one that has been compiled and transferred to the PLC. If you have created a new file (i.e. the fi le name is "Untitled" ) and then attempt to perform on-line monitoring, this comma nd will be called automatically to try to open a file that matches the PLC. The command is also invoked when you select a PLC with a different ID either fr om the "Controller" menu or from within the "Full-Screen Monitoring" window. Note to Unicode users: If you created yo ur file name using Unicode instead of plain ASCII, the Unicode filename will no t be saved into the PLC since TRi PLCs currently do not support Unicode in its in ternal memory. In such case you cannot use this command to open the matching source file. You would have use the "File -> Open (Local Drive)" command to manually open the file for monitoring purpose. 8.3.7 Get PLC's Hardware Info

149. Chapter 8 8-43 8.5 Circuit Menu 8.5.1 Insert Comments Comments are specific remarks used by a programmer to explain various characteristics of a program segment and are ignored by the compiler. TL6 allows comments to be freely inserted between circuits. Execute this command and the Comment Editor will be opened . The comment editor allows you to enter any text you like that best describe the working of the circuit. All standard text editing keys, including cut and paste are applicable to the Comment Editor. In early versions of i-Trilogi, you would press the <ESC> key or click the button to close the comment window and auto matically save the changes when you had finished editing it. i-Trilogi 6.2 and higher allows you to save and close the comment the same way as before or by clicking the button. It is also possible to exit the comment and discard any changes made since it was last opened by clicking on the new button. Once a comment has been created, it is assigned a circuit number and is treated like any other circuits. You can ed it it by pressing the <spacebar> when you are in Browse mode, al ternatively, you can move it around, copy it to another destination or delete it entirely using commands in the "Circuit" menu. Note: Since TL6 is Unicode-aware, you can now enter comments text in any international language and as long as the file is saved with a ".PC6" the comments will be properly saved into the da ta file and will be properly reloaded when the file is next open. 8.5.2 Insert Circuits This command enables you to insert a new circuit just be fore the currently selected circuit. The curr ent circuit number will be increased by one while the new circuit will assume the current circui t number. You will be placed in the circuit editing mode for immediate circuit creation. 8.5.3 Move Circuit You can rearrange the order of the circuits by using this command. Select the circuit you wish to move and execute the "Move Circuit" command, then

184. Chapter 10 10-12 10.3.1 Find If you select the "Find" menu, you will see the following window popup and you will be able to type text in the field that will be searched for within the Define table. 10.3.2 Insert Row A new blank row will be inserted above the row where the cell is highlighted when the mouse was right clicked. The highlighted row and all other rows below will be shifted down by 1 row and their row number will increase by 1. 10.3.3 Delete Row The row that was highlighted when the mouse was right clicked will be deleted. All other rows below the highlighted row will be shifted up by 1 row and their row number will decrease by 1.

213. Chapter 11 11-10 TRiLOGI Program Code Result Expression1 D would equal A + B + C IF A = 1 Expression3 ELSE B = 1 ENDIF If A equals 1, Expression3 will execute and the following code will run : If DM[1] = DM[2]:DM[3] = 1111:ENDIF If A does not equal 1, B will be equal to 1 Long_Expression The following code would execute : FOR I = 1 TO 1000 : DM[I] = I*2 : X=X+1 : CALL 2 : NEXT 11.3 String Constants, Variables & Operators A string is a sequence of alphanumeric characters (8-bit ASCII codes) which collectively form an entity. 11.3.1 String Constants A string constant may contain from 0 to 70 characters enclosed in double quotation marks. e.g. "TBASIC made PLC numeric processing a piece of cake!" "$102,345.00" 11.3.2 String Variables TBASIC supports a maximum of 26 string variables A$ , B$ ... Z$. Each string variable may contain from 0 (null string) up to a maximum of 70 characters. Note: For all NANO-10, FMD Series, and F-Series PLCs (as well as legacy M-series PLCs with firmware version r44 and above), you can access the 26 string variables using an index: $$[1] to $$[26]. I.e. A$ is the same as $$[1], Z$ is the same as $$[26]. Note that $$[1] to $$[26] are not additi onal string variables, it just give you a way to index the string variables not po ssible on previous firmware version. Also, only i-TRiLOGI version 6 and above properly support these variable names. Caution: Do not try to transfer a prog ram using $$[n] variable to a PLC with firmware earlier than r45 as it can cause the PLC operating system to crash.

272. Chapter 12 12-56 COMM2: d = &H0101 to &H01FF COMM3: d = &H0201 to &H02FF COMM4 (Ethernet): d = &H0301 to &H03FF ID for the respective COMM port will be set to 01 to FF after running the above command. (only applicable to PLC with firmware r76 and above) 9 1 0 12.72.8 Fast Refresh data = 1 : to enable Fast I/O REFRESH ONLY data = 0 : (default) REFRESH all i/os On FMD PLCs the fast I/Os are input 3 to 6 and output 5 to 8. On F-series PLCs, the fast I/Os are inputs 1 to 12 and outputs 5 to 16. All Nano-10 I/Os are fast I/Os so this command has no effect. By running SETSYSTEM 9,1 - only the fast I/Os are refreshed when TBASIC REFRESH command is run. This has the advantage of reducing the REFRESH latency (especially when executed within a interrupt service custom function).

278. Chapter 12 12-62 12.73 SetTimerSV n, value Purpose : Change the Set Value (S.V,) of the Timer #n to value . This statement to allow the user to modify the S.V. of the PLC internal timers without changing the source program. A TBASIC function can be written easily to make use of a few digital or analog inputs to mo dify the SV of these internals timers. Parameters : N - should be between 1 and 128. Value- should be between 0 and 9999. Examples : SetCtrSV 10,1234 SetTimerSV 3, GetTimerSV(3)+10 Counter #10 will assume a S.V. of 1234.. S.V of Timer #3 will be increased by 10. Comments : For F-series PLC the new S.V is stored in the onboard FRAM and hence is non-volatile. (See sample program "set_TCSV.PC4"). For Nano-10 and FMD PLC , the new S.V. are only stored on RAM-shadowed CPU flash memory and is normally volatile unless a RESET or SETSYSTEM 252, 0 command has been executed which forces a backup of the RAM shadow to the CPU flash memory. Programmer should therefore use this command sparingly. Note that TBASIC custom funciton can start a timer simply by setting its TIMERPV[] variable to any integer value between -1 (reset timer) and 9999 so it is not necessary to change the timer S.V.. The present values (P.V.) of timers can be read or written directly as integer variables "T imerPV[n]". But the Set Values can only be changed by this function. See Also : GetCtrSV( ), GetTimerSV( ) , SetCtrSV 12.74 SLEEP Purpose : To put the PLC CPU into sleep mode to save power.

302. Appendix 1 A1-8 g) Wait while the program transfer takes place (below-left screenshot). h) Click ‘Reset’ when the program transfer is complete (above-right screenshot). The program transfer is now complete and online monitoring can be performed. 9) ONLINE MONITORING Select “On-Line Monitoring” from the “Controller” menu (or press CTRL + M on the keyboard).

304. Appendix 1 A1-10 then refer to chapter 2 of your PLCs user manual for details on configuring the network settings via serial port connection. 2) START TRILOGI Refer to the START TRILOGI section in Part 1 of this guide. TLServer is not needed for Ethernet communication, so there is no need to start it or configure it. 3) OPEN FILE Refer to the OPEN FILE section in Part 1 of this guide. 4) PROGRAM TRANSFER a) Select “Program Transfer to PLC” from the “Controller” menu (or press CTRL +T on the keyboard).

327. Appendix 4 A4-3 can automatically detect the RS232 speed of the device and can assume any speed from 1200, 2400 all t he way to 115,200 bps. The first ASCII character they receive from the device will determine the DTE speed that the modem will use to communicate with the device. • The "modem-to-modem communication speed" is what you read on the modem specifications, such as 33.6K bps, 56Kbps etc. When two modems are connected, they automatically negotiate for the best speed to communicate between the two of them based on the quality of the phone connection and the maximum speed that both modems are able to achieve. We usually have no co ntrol of what speed they choose to communicate. But one thing is for su re, which is that the modem-to- modem speed is always lower than the DTE speed. Since the default communication baud rate of the 'Super' PLC’ s RS232 serial port is 38,400 bps, the PLC should send a modem initialization string to the modem on the first scan pulse so that the modem can recognize its default DTE speed (i.e. 38,400 bps) in order to talk to the PLC. E. g. To reset the modem, you just have to send an ASCII string "ATZ" to the modem using the following TBASIC command: PRINT #1 "ATZ" If you want your modem to automatically answer to an incoming call (e.g. using TLServer 2.x/3.x modem dialing capability), then you should execute the following TBASIC statement: PRINT #1 "ATS0=1" The above statement will tell the modem to answer on first ring, you can also change the number 1 to other numbers, E. g. if ATS0=3 it will answer on the 3 rd ring of the phone. A4.3 Software and Programming The TLServer 3.0, which is part of the In ternet TRiLOGI 6.x software suite, already includes built-in support for dialing a modem. Hence if you are using the PLC in passive answer mode only, all the PL C needs to do is to send a modem initialization string "ATS0=1" using the "1 st.Scan" pulse to put the modem in auto- answer mode whenever the PLC is powere d up. The PLC does not need to issue any more commands to the modem. Whenever a user wants to communicate with the PLC, he/she will first use the TL Server to dial and connect to the PLC’s modem and when the connection is establis hed, he/she will then be able to use

159. Chapter 9 9-7 1.0 second Clk:1.0s 1 minute Clk:1min A clock pulse bit is ON for the first ha lf of the rated period, then OFF for the second half. Duty cycles for these clock pulse bits are therefore 50%, as follow: The clock pulse bits are often used with counter instructions to create timers. Additionally, they can be used as timing source for "Flasher" circuit. A reversible counter can also work with a clock pulse bit to create secondary clock pulses of periods that are multiples of the basic clock pulse rate. 9.2.2 SeqN:X These are special "Sequencer" contacts which are activated only when the step counter of a Sequencer N reaches step #X. E.g. a Normally Open contact Seq2:6 is closed only when Sequencer #2 reaches Step #6. At any other step, this contact is opened. Click this li nk for detailed explanation and working examples on how to use a Sequencer. 9.2.3 Normally ON Flag - Norm.ON You can make use of this flag if you need to keep something permanently ON regardless of any input conditions. This is because with the exception of Interlock Off function ———[ILoff], a coil or a spec ial function is not allowed to connect directly to the power line (the vertical line on the left end of the ladder diagram). If you need to permanently enable a coil, consider using the "Normally-ON" bit from the "Special Bits" menu, as follow: 9.2.4 First Scan Pulse - 1st.Scan

250. Chapter 12 12-34 12.49 REM (or ') Statement Purpose : To allow explanatory remark s to be inserted in a program. The text after the REM statement un til the end of the line will be ignored by the compiler. An abbreviation for the REM statement is the apostrophe ( ' ) Examples : REM Waiting for the right time to turn on ' This is also a remark line. 12.50 RESET Purpose : To perform a software reset of the PLC from within a CusFn. All the variables will be reset to zero or inactive and all the hardware outputs such as DAC and PWM will be turned OFF. The effect is the same as the Ma ster Reset [MaRST] function in the ladder logic. The first scan bit (1st.Scan) will also be turned ON for one scan time. A RESET will also perform a FLASH memory backup for all NANO-10 and FMD series PLCs. This is especially important after any SETTIMERSV , SETCTRSV , or SET_IPADDR commands are executed because the ti mer and IP data must be backed up into FLASH. However, it is better to use the SETSYSTEM 252,0 command to perform a FLASH backup since a RESET will cause all volatile data to be lost. Comments : If the program is stuck at some dead loop (such as WHILE, FOR-NEXT) in a CusFn, then [M aRST] would not be executed since the ladder program would not have a chance to scan the ladder rung containing t he [MaRST] function. If this command is used by an interrupt service function, then it is possible to get the system out of the dead loop since the interrupt function can interrupt the dead loop and reset the PLC. 12.51 RESTART REBOOT

261. Chapter 12 12-45 12.63 SetCtrSV n, value Purpose : Change the Set Value (S.V,) of the Counter #n to value . This statement to allow the user to modify the S.V. of the PLC internal counters without changing the source program. A TBASIC function can be written easily to make use of a few digital or analog inputs to mo dify the SV of these internals timers/counters. Parameters : N - should be between 1 and 128. Value- should be between 0 and 9999. Examples : SetCtrSV 10,1234 SetCtrSV 3, GetCtrSV(3)+10 Counter #10 will assume a S.V. of 1234.. S.V of Counter #3 will be increased by 10. Comments : For F-series PLC the new S.V is stored in the onboard FRAM and hence is non-volatile. (See sample program "set_TCSV.PC4"). For Nano-10 and FMD PLC , the new S.V. are only stored on RAM-shadowed CPU flash memory and is normally volatile unless a RESET or SETSYSTEM 252, 0 command has been executed which forces a backup of the RAM shadow to the CPU flash memory. Programmer should therefore use this command sparingly. Note that TBASIC custom funciton can start a counter simply by settin g its CTRPV[] variable to any integer value between -1 (reset counter) and 9999 so it is not necessary to change the counter S.V.. The present values (P.V.) of counters can be read or written directly as integer variables "CtrPV[n]". But the Set Values can only be changed by this function. See Also : GetCtrSV( ) , GetTimerSV( ) , SetTimerSV 12.64 SETDAC n, x Statement

202. Chapter 10 10-30 Illegal acceleration for STEPMOVE! STEPMOVE channel out-of-range! STEPSTOP channel out-of-range! ADC channel out-of-range DAC channel out-of-range LED Digit # within (1-12) Only! PWM Channel out-of-range! LCD Line # must be (1-4) Only! PM channel out-of-range! System Variable Index Out-of-range! Shifting of (A-Z) Out-of-range! Illegal Opcode - Please Inform Manufacturer! Timer or Counter # Out-of-Range!

212. Chapter 11 11-9 The following explanations will reference the above example define table. a) Creating Variable Definitions It is possible to define label names for any variable available in TRiLOGI. The following results will happen based associated program code : TRiLOGI Program Code Result Name1 = 10 DM[1] would contain the value 10 Name4 = Name5 * 5 A would contain B x 5 DM[Name2] = Number1 DM[DM[1]] would equal 1 b) Creating Constant Definitions It is possible to define label names for constant values. The following results will happen based associated program code : TRiLOGI Program Code Result A = A + Number1 A would contain its current value plus 1 DM[Number1] = 2 DM[1] would equal 2 c) Creating Expression Definitions It is possible to define label names for entire expressions or code snippets. The following results will happen based associated program code :

236. Chapter 12 12-20 A$ = INPUT$(1) ‘ Read from COMM1 IF LEN(A$)<> 0 ‘ String is not empty. RETURN ‘ A$ contains data. ENDIF NEXT SETLCD 1,1, “Nothing received” Comments : A Carriage Return (CR) or ASCII code 13 marks the end of a valid input string from the co mmunication port. The returned string however will exclude t he CR character. In TRiLOGI simulator, the user will be prom pted to enter the string in a pop-up window. See Also : INCOMM( ) , PRINT # , OUTCOMM 12.30 INTRDEF ch, fn_num, edge Purpose : Enable Interrupt Input channel #ch. ch = channel number (1-8) fn_num = Custom Function numb er to execute when interrupt pin changes according to the defined edge. This is the Interrupt Service Routine ISR. edge = Positive number means rising edge-triggered. 0 or negative number means falling-edge triggered. See Also : INTROFF 12.31 INTROFF ch Purpose : Disable Interrupt Input channel # ch. See Also : INTRDEF 12.32 LEN (x$) Purpose : To return the number of characters in x$. Examples : L = LEN("This is a test string"+CHR$(13)) Comments : L = 22 because blanks and non-printing characters are counted.

259. Chapter 12 12-43 function that runs SET_ SUBN ET 100 to write the new SUBNET address into the PLC. For Nano-10 and FMD PLCs , you should soft-reset (using the RESET or SETSYSTEM 252, 0 command) and rest art (cold boot) the PLC after changing the SUBNET address so that the new SUBNET address will be saved into the virtual EEPROM The PLC will only assume the new SUBNET address after it has been rebooted (via the REST ART command or power-on reset). Example : DM[100] = 255 DM[101] = 255 DM[102] = 255 DM[103] = 0 SET_ SUBNET 100 ‘Set the SUBNET address to 255.255.255.0 Note : This command is ignored by i-TRiLOGI simulator. See Also : GET_SUBNET , SET_DNS , SET_GATEWAY , SET_SMTP , SET_IPAddr 12.61 SETBAUD ch, baud_no Purpose : To set the communication “Baud Rate” of the PLC’s serial channel #ch. All of the ‘Super’ series PLC serial ports are defined as 8 data bit, 1 stop bit, and no parity and each has been preset to a certain default baud rate, which the PLC will assume every time its powers up. The baud rate may or may not be changed, depends on t he PLC model. Please refer to the PLC’s User’s manual for t he baud_no that represent the baud rate of each serial channel and the range of baud_no each of these serial ports may assume. Caution should be taken when programming the baud rate of the “Host link” port because if a wrong baud value is set the host PC may not be able to communicate with it. If this happens, suspend the PLC using its hardware switch (such as DIP switch #4 on the FMD or F-series PLCs and jumper J4 on the Nano-10) and re-load the program with the correct

301. Appendix 1 A1-7 c) Click “Detect ID” and the PLC ID should be retu rned in the adjacent field, as shown below, if communication is functioning correctly. d) Click OK to complete the server login process. e) Click ‘Yes’ to continue when prompted with the program transfer confirmation window: f) Click ‘Start Transfer’ to initiate the actual program transfer if is displayed, which indicates program compilation was successful.

328. Appendix 4 A4-4 the TRiLOGI client or the TRi-ExcelLink program to communicate with the PLC. The fact that the PLC is connected via mo dem and not via direct RS232 is totally transparent to the client programs. To prevent unauthorized access to the PLC, you may need to use the TBASIC command "SETPASSWORD" to set a protective password. The great flexibility of these PLCs becomes even more apparent when you realize that you can easily program the PLC to automatically dial in to the TLServer to perform a number of tasks, such as using the PLC’s File Service to save or append data to hard disk files, send email to anyone via the Internet or even synchronize its real time clock with the host PC! A number of examples ha ve been included in the "C:\TRiLOGI\TL6\usr\samples\FileServic e_Modem" folder when you installed TRiLOGI version 6.x. All these examples ma ke use of a powerful yet easy to use custom function that was written entir ely using the standard TBASIC commands (see source code listing in the text bo x below). You only need to create the following simple ladder circuit to use this function (assuming it is function #10): D$ = "ATDT*802" ' store the phone number IF TESTIO(Connected) THEN ' already connected. IF TESTIO(DialModem)=0 ' connection no longer needed IF DM[3991]=0 ' used as timer for modem attention. PRINT #1 ' clear serial-out buffer. WHILE INCOMM(1)<> -1 ' clear whatever data in serial-in buffer ENDWHILE ELSE IF DM[3991]=5 PRINT #1 "+++"; 'get modem attention ELSE IF DM[3991]>=10 'Wait 5 second to gain attention. PRINT #1 "ATH" 'hang up modem command. CLRIO CONNECTED DM[3991]=0 ENDIF ENDIF ENDIF

14. Chapter 1 I-TRiLOGI Setup Guide 1-1 1 I-TRILOGI 6 SETUP GUIDE 1.1 Introduction to the i-TRiLOGI Program i-TRiLOGI is a trademark name used by Triangle Research International to describe its family of Ladder and La dder+BASIC program editor, compiler, simulator and program up-loader software. The Internet TRiLOGI 6.x client/server suit e is written to run under all currently available 32-bit Microsoft Windows op erating systems as Windows 98, Me, NT, 2000, XP, and Vista. By installing the 32-bit Java Runtim e environment: JRE 1.4.2_19 that is shipped with the I-TRiLOGI CD-ROM or download website, I-TRiLOGI has also been tested to run properly under 64-bit Windows 7 / 8 operating systems. 1.2 Download the Latest Version of I-TRiLOGI If this is the first time you are installi ng I-TRiLOGI, you should locate and open the “upgrade.htm” document in the I- TRiLOGI CD-ROM which provides the web link, username and password to login to the TRi website to download the latest version. If you already have a current version of I-TRiLOGI, you can click on the “Help” menu on I-TRiLOGI and sele ct the “Upgrade TRiLOGI” command which will also open up the “Upgrade .htm” document. Either case, please login to the upgrade website and download the latest version of SetupTL6xxx.exe. Then proceed to Sectio n 1.3 to install the JRE first BEFORE installing the I-TRiLOGI. 1.3 Install Java Run Time Enviroment JRE 1.4.2_19 1. In the root directory on the Inte rnet TRiLOGI 6.x CD-ROM, you should find a folder “x86-Windows” which is where all the setup files for PCs running MS Windows are located. i-TRiLOGI is written in Java and requir es a Java Run Time Environment (JRE) installed on the PC in order to run prop erly. The i-TRiLOGI 6.xx CD ROM includes a copy of the JRE 1.4.2_19 setup program with the filename:

195. Chapter 10 10-23 10.6 On-line Monitoring of TBASIC Variables If you execute the "On-Line Monitoring/Control" command from the "Controller" pull-down menu, i-TRiLOGI will continuous ly query the PLC for the values of all their internal variables. These variables’ va lues will be updated in real time in the "View Special Variables" window as described in Section 5.2. You may also alter the value of any variables in the PLC using the "Edit Variable" window (by clicking on the "Edit" button at the "View xxx Variables" window. This ability of i-TRiLOGI to provide instant and full visibility of all the PLC’s internal variables greatly facilitates the progra mmers’ debugging process. The ease of programming offered by the i-TRiLOGI pr ogramming environment is really what really sets the Nano-10, FMD series, an d F-Series PLCs apart from many other PLCs. 10.6.1 PAUSE and RESET of Target PLC During On-Line Monitoring, if the "View Special Variables" window is opened, you can still reset the PLC’s internal data by pressing the <Ctrl-R> key. The PLC can also be halted by pressing the <P> ke y. A halted PLC can subsequently be released from the halted mode by pres sing the <P> key ag ain. You can also change any internal variable data using the "Edit" button on the View Variable screen. 10.6.2 Using LCD Display for Debugging You should take advantage of the built-in LCD display port of the PLC to display internal data at the location where you wa nt to track their values, especially if the value changes rapidly which may not be constantly captured by on-line monitoring screen. 10.7 Debugging With PAUSE & Breakpoints 10.7.1 Using the TBASIC PAUSE Statement When debugging your program it is often easier to identify program bugs by pausing the PLC at a certain execution po int so that you can examine the data in the variables to understand why the program does not behave the way you expect it to. TBASIC offers the "PAUSE" st atement which is always available in all versions of i-TRiLOGI software and supported on all firmware versions of the Super PLCs.

288. Chapter 12 12-72 Purpose : To abort a stepper channel #ch that is in motion due to exceptional circumstances (NOT intended for normal motor control operation). Examples : STEPSTOP 2 Important : Motion aborted by STEPSTOP command will not trigger the end-motion relay #r specified in the STEPMOVE command. See Also : STEPCOUNT , STEPSPEED , STEPMOVE 12.83 STR$(n) STR$ (n, d) Purpose : To return a string that represents the decimal value of the numeric argument n. If the second format is used then this function will return a string of ‘d’ number of characters. Examples : A$ = STR$(-1234) B$ = STR$(-1234,7) Comments : A$ will contain the string : "-1234" , B$ will contain the string “- 001234” 12.84 STRCMP(A$, B$) Purpose : Perform a comparison betw een its two string expressions A$ and B$. IF A$ and B$ are equals, ST RCMP will return a 0, if A$ is of lower order (in ASCII table or der) than B$ the function will return a negative value. Otherwise it returns a positive value. Examples : IF STRCMP(A$, B$)=0 THEN STEPMOVE 1,1000,1 ENDIF Comments : IF A$ and B$ are the same then turn on the stepper motor #1. 12.85 STRLWR$(A$)

26. Chapter 2 – Introduction To I-TRiLOGI 2-2 TLServer All TRi ‘Super’ PLCs (including legacy PLCs that do not have built-in Ethernet port, such as the T100MD+ and T100MX+ fami ly) can still be programmed using the same i-TRiLOGI software via a PC-based server software called "TLServer" that converts TCP/IP packets to serial communication (RS232/RS485) . TLServer behaves like a typical web serv er and it is capable of serving HTML webpages as well as Java Applet to an In ternet Browser such as Firefox, Chrome or Internet Explorer. TLServer connects to the PLCs via the PC's serial communication port and it is the one responsible for conveying communication messages between the i-TRiLOGI client and the ‘Super’ PLCs. (Note: TLServer is not included with Education version of i-TRiLOGI since there is no real PLC involved.) Therefore if your PLC does not have Ethernet connection, then you must run TLServer in order to program or configure the PLC. To Start TLServer, double-click on its Icon and a TLServer panel will appear. You can mi nimize TLServer but it should be actively running in order to se rvice network requests from i-TRiLOGI via the Internet or local area network. 2.2 i-TRiLOGI Client Software Versions i-TRiLOGI client software is available in two versions: 2.2.1 Java Application The i-TRiLOGI program (as well as the JVM, see below) must be locally installed in the PC that it runs on. 2.2.2 Java Applet The client computer only needs to use a Java-enabled Web browser such as the Internet Explorer 6.x or Mozilla Fire Fo x to invoke the i-TRiL OGI applet that is stored in the TLServer. There is no need to install the i-TRiLOGI software in the local computer.

167. Chapter 9 9-15 moment, there must be a "step counter" to keep track of the current step number. Every step of the sequence must be accessible and can be used to trigger some action, such as turning on a motor or solenoid valve, etc. As an example, a simple Pick-and-P lace machine that can pick up a component from point 'A' to point 'B' may operate as follow: Step # Action 0 Wait for "Start" signal 1 Forward arm at point A 2 Close gripper 3 Retract arm at point A 4 Move arm to point B 5 Forward arm at point B 6 Open gripper 7 Retract arm at point B 8 Move arm to point A i-TRiLOGI Version 6 and higher supports eight sequencers of 32 steps each. Each sequencer uses one of the first eight coun ters (Counter #1 to Counter #8) as its step counter. Any one or all of the first eight counters can be used as sequencers "Seq1" to "Seq8". To use a sequencer, first define the se quencer name in the Counter table by pressing the <F2> key and scroll to the Counter Table. Any counter to be used as sequencer can only assume label names "Seq1" to "Seq8" corresponding to the counter numbers. For e.g. if Sequencer #5 is to be used, Counter #5 must be defined as "Seq5". Next, enter the last step number for the program sequence in the "Value" column of the table. Construct a circuit that uses the specia l function "Advance Sequencer" [AVSeq]. The first time the execution condition for the [AVseq] function goes from OFF to ON, the designated sequencer will go fr om inactive to step 1. Subsequent change of the sequencer's execution condition from OFF to ON will advance (increment) the sequencer by one step. This operation is actua lly identical to the [UPctr] instruction. The upper limit of the step counter is dete rmined by the "Set Value" (SV) defined in the Counter table. When the SV is reached, the next advancement of sequencer will cause it to overflow to step 0. At this time, the sequencer's

185. Chapter 10 10-13 10.3.4 Copy Row The row that was highlighted when the mouse was right clicked will be copied. 10.3.5 Paste Row The row that was previously copied will be pasted to the row highlighted when the mouse was right clicked. 10.3.6 Import #Define Table You will first be asked if you want to cl ear the content of the #Define Table and you will want to say 'Yes' to proceed with the import (say 'No' and do an export first if you want to save the current table). An example define table exported to an Excel file (automatically exported in "Tab Delimited" format) is shown above. Note: row #1, which must be included exactly as shown above in order for the file to properly be imported into the define table. You will then need to browse your PC for the .txt (Tab delimited text file) that you have previously exported or created and are now importing. Once you select it, the define table will be populated with all the definitions. Note: If you are have manually created a "# Define" table using Excel spreadsheet program, you will need to use the correc t format in your spreadsheet (shown above) and ensure that the file is saved in the "Tab Delimited format" (not the standard spreadsheet format) with a ".txt" file extension.

186. Chapter 10 10-14 10.3.7 Export #Define Table You can export all the items in the #Defi ne table of a currently opened .PC6 file to the PC harddisk so that the these de finitions can be imported into another .PC6 program. When you select "Export #Define Table" you will just need to name and save the file with ".txt" ext ension to your desired location. The data are stored in TAB-delimited format, which can be opened directly by a Microsoft Excel program for viewing or editing. 10.3.8 More Information on #Define Tables Please refer to the Integer Constants, Variables and Operators section or the String Constants, Variables and Operator s section for more information on how to use the define table in your PLC program. 10.4 How to Use A Custom Function It is important to understand when and how a TBASIC-based Custom Function is executed with respect to the rest of t he program. There are basically two ways in which a CusFn will be executed: 10.4.1 Triggered by Ladder Logic Sp ecial function coil [CusFn] A custom function may work the same way as any other special functions in the i-TRiLOGI ladder diagram programming environment. When you are in ladder circuit editing mode, press <Ins> key to open the "Ins Element" menu. Select the item or to create a special function output. A pop-up "Select a Function" menu will appear.

258. Chapter 12 12-42 12.59 SET_SMTP dmindex Purpose : To set the SMTP address of this PLC's built-in Ethernet port using the parameters stored in DM[dmindex] to DM[dmindex+4]. Comments : To change the SMTP address of a PLC's Ethernet port, you can load the new SMTP address and port number into the variables DM[100] to DM[104] (e.g. from a HMI panel) and then invoke a function that runs SET_ SMTP 100 to write the new SMTP address into the PLC. For Nano-10 and FMD PLCs , you should soft-reset (using the RESET or SETSYSTEM 252, 0 command) and rest art (cold boot) the PLC after changing the SMTP address so that the new SMTP address will be saved into the virtual EEPROM The PLC will only assume the new SMTP address after it has been rebooted (via the REST ART command or power-on reset). Example : DM[100] = 192 DM[101] = 168 DM[102] = 1 DM[103] = 101 DM[104] = 587 SET_IPAddr 100 ‘ Set the IP address to 192.168.1.101:587 Note : This command is ignored by i-TRiLOGI simulator. See Also : GET_SMTP , SET_DNS , SET_GATEWAY , SET_SUBNET , SET_IPAddr 12.60 SET_SUBNET dmindex Purpose : To set the SUBNET address of this PLC's built-in Ethernet port using the parameters stored in DM[dmindex] to DM[dmindex+3]. Comments : To change the SUBNET address of a PLC's Ethernet port, you can load the new SUBNET addre ss into the variables DM[100] to DM[103] (e.g. from a HMI panel) and then invoke a

277. Chapter 12 12-61 255 &HB3 &HAB &H03 &H00 data All F-series FMD & Nano-10 >= r79 firmware FMD & Nano-10 <= r78 firmware &HB3 Time out in 2.24s Time out in 2.67s Time out in 4.47s &HAB Time out in 0.14s Time out in 0.17s Time out in 0.28s &H03 Diable WDT (default) Diable WDT (default) Diable WDT (default) &H00 Reset WDT Reset WDT Reset WDT If enabled and the CPU goes astray because of noise- induced trouble, the WDT will reset the CPU when it times out. Note that to simplify user's application the TBASIC O/S automatically resets the WDT during its normal execution except when the program is st ucked inside a GOTO loop. Hence if your program is likely to spend longer time within a GOTO loop than the predef ined timeout, you must run the SETSYSTEM 255, 0 command periodically to reset the WDT before it times out, to prevent the WDT from resetting the CPU. However, the WDT will not kick in if your program is stucked inside a FOR..NEXT or WHILE.. ENDWHILE loop. WDT also will not activate if your program encounters undefined interrupt error in order to give the programmer a chance to investigate the cause that leads to the Undef. Interrupt error. Applicable only to PLC with firmware r74 and above. 256 0 1 12.72.21 I/O Scan Interrupt data = 0 : (default) do not process user interrupt during I/O scan interrupt latency determined by scan time. data = 1 : process pending user interrupt even during I/O scan (to minimize interrupt latency). Available to PLC with firmware r50 and above.

298. Appendix 1 A1-4 5) TEST COMMUNICATION FROM TLSERVER In the same Serial Port Setup screen, type the following command in the Command String field to read the PLCs ID (default ID is 01): Command String : IR* Response String : IR01* If you get the message (Warning: No Response From PLC!) , then communication is not setup properly. First repeat the steps from PLC connection to TLServer

25. Chapter 2 – Introduction To I-TRiLOGI 2-1 2 INTRODUCTION TO I-TRILOGI CLIENT/SERVER 2.1 Client/Server Architecture i-TRiLOGI is a Client/Server application suite. The ent ire program is broken into two parts: the Server and the Client. 2.1.1 Client The i-TRiLOGI program is the one which you use to create your ladder logic + TBASIC program and is called the "Client" program. (If you are programming the PLC offline then you only need to run the client program without the server.) The beauty of the client/server configuration is that it does not matter whether the server and client are located at the same computer or at 10,000 miles apart and they work exactly the same way. The client and the server can communicate via any form of network co nnection, including the Internet. This makes it possible for the user to program the PLCs either locally or remotely via the Internet or even wirelessly via mobile Internet. Another important advantage of client/serve r architecture is that multiple clients may access the same server simultaneous ly. Hence you can run multiple copies of the i-TRiLOGI clients at different plac es around the world simultaneously for troubleshooting a single PLC. You can al so run the i-TRiLOGI client AND the TRi- ExcelLink (separate data collection software) clients simultaneously! 2.1.2 Server Since i-TRiLOGI client program only communicates using TCP/IP networking protocol, it needs to connect to a "server" th at listens on a TCP/IP port waiting for connections from i-TRiLOGI or other client programs. FServer Most of the newer TRI's brand of PLC, such as Nano-10, FMD and F-series PLCs have a built-in web server called "FServer" that is located on the PLC CPU chip, and the i-TRiLOGI client can connect to it directly for programming and online monitoring. The FServer can perform other tasks that a typical web server can do, such as host web pages and receive connections from other devices/software. Please refer to the PLC's User's Manual for details.

158. Chapter 9 9-6 coil is energized or not. To turn O FF these contacts, you have to reset the counter using a special counter reset function [RSctr]. 9.2 Special Bits i-TRiLOGI contains a number of special pu rpose bits that are useful for certain applications. These include 8 clock pulses ranging from periods of 0.01 second to 1 minute, a "Normally-ON" flag and a "F irst Scan Pulse", etc. To use any of these bits, enter the ladder editor and create a "contact"; when the I/O table pops up, scroll the windows until a "Special Bits" menu pops up. This menu is located after the "Counter Table" and before the "Input" table. as shown below: 9.2.1 Clock pulse bits The 8 clock pulses supported by i-TRiLOGI are: Clock Pulse Period Ladder Symbol 0.01 second Clk:.01s 0.02 second Clk:.02s 0.05 second Clk:.05s 0.1 second Clk:0.1s 0.2 second Clk:0.2s 0.5 second Clk:0.5s

279. Chapter 12 12-63 Comments : Upon execution of this command the CPU will enter a low power sleep mode but it can be woken up by a serial interrupt or an active I/O interrupt. However, this will only save power consumed by the CPU and does not save the static power required by other co mponents on the PLC circuit board. Note: 1. Command available only to PLC with firmware r67 and above. 2. Do not execute this command with active Ethernet connection as it can trigger the CPU to lock up into undefined interrupt error state. Only application that are not connected to the Ethernet should use this command. 3. This command is ignored by i-TRiLOGI simulator. 12.75 STATUS (n) Purpose : Return the status of va rious system operations. Returned values may be dependent on the PLC model. STATUS(n) RETURNED VALUE (v) DESCRIPTION 1 0 1 Reset Status v = 0 : Normal power on reset v = 1 : Reset by Watch Dog Timer (WDT) 2 0 1 255 Command Status Used to check the status of a command sent to a device. v = 0 : command failure v = 1 : command successful v = 255 : End of File reached

299. Appendix 1 A1-5 setup and if there is still no re sponse, refer to the Communication Troubleshooting Appendix at the end of this document. 6) START TRILOGI Start TRiLOGI by selecting “ i-TRiLOGI Version 6.4 ” from “ i-TRiLOGI 6 ” in your PCs start menu (below, left screenshot). Once opened, you will see the TRiLOGI programming environment window (below, right screenshot): Start Menu 7) OPEN FILE For the purposes of this tutorial, the Demo .PC6 program will be referenced. This is a sample program that is included in the i-TRiLOGI installation. This sample program, as well as all the other included sample programs, is accessible from the “ C:\TRiLOGI\TL6\usr\samples ” folder. Below is the Demo.PC6 program:

224. Chapter 12 12-8 Assuming the IP address st ored in the PLC is 192.168.1.101 and the port number is 9080: DM[100] = 192 DM[101] = 168 DM[102] = 1 DM[103] = 101 DM[104] = 9080 Note : This command is ignored by i-TRiLOGI simulator. See Also : SET_IPAddr , GET_DNS , GET_GATEWAY , GET_SMTP , GET_SUBNET 12.14 GET_DNS dmindex Purpose : To return the DNS address of this PLC's built-in Ethernet port and store each '.' separated valued in DM[dmindex] to DM[dmindex+3]. Comments : To return the DNS addre ss of a PLC's Ethernet port into the variables DM[100] to DM[103] (e.g. to display on a HMI panel), you can invoke a function that runs GET_ DNS. Example : GET_DNS 100 ‘ Return the DNS address Assuming the DNS address stored in the PLC is 192.168.1.101: DM[100] = 192 DM[101] = 168 DM[102] = 1 DM[103] = 101 Note : This command is ignored by i-TRiLOGI simulator. See Also : SET_DNS , GET_IPAddr , GET_GATEWAY , GET_SMTP , GET_SUBNET 12.15 GET_GATEWAY dmindex

226. Chapter 12 12-10 Note : This command is ignored by i-TRiLOGI simulator. See Also : SET_SMTP , GET_DNS , GET_GATEWAY , GET_IPAddr , GET_SUBNET 12.17 GET_SUBNET dmindex Purpose : To return the SUBNET addre ss of this PLC's built-in Ethernet port and store each '.' separated valued in DM[dmindex] to DM[dmindex+3]. Comments : To return the SUBNET address of a PLC's Ethernet port into the variables DM[100] to DM[103] (e.g. to display on a HMI panel), you can invoke a function that runs GET_SUBNET. Example : GET_SUBNET 100 ‘ Return the DNS address Assuming the DNS address stored in the PLC is 255.255.255.0: DM[100] = 255 DM[101] = 255 DM[102] = 255 DM[103] = 0 Note : This command is ignored by i-TRiLOGI simulator. See Also : SET_SUBNET , GET_DNS , GET_GATEWAY , GET_SMTP , GET_IPAddr 12.18 GetCtrSV (n) GetTimerSV (n) Purpose : Return the Set Value (S.V,) of the Counter #n or Timer #n. n should be between 1 and the maximum number of timers and counters in your PLC. Note : Although the present values (P.V.) of timers and counters #n can be accessed directly as variables “TimerPV[n]” & “CtrPV[n]”, the Set Values however can only be obtained by these two functions.

270. Chapter 12 12-54 data (d) is applied to all 3 COMM ports simultaneously and can be any value from 0 to 255 e.g. SETSYSTEM 2,5 The PLC will retry up to 5 times if it failed to communicate with the slave. Note that there will be longer waiting times when failures occur if you increase the number of retries. 3 0 1 12.72.3 Hostlink Command Response Time data = 0 : Respond as fast as possible to serial port hostlink commands received from the host computer or another PLC. data = 1 : (default) at least a 0.01s (10ms) must lapse before responding to host link commands received from the host computer or another PLC. This delay is needed for auto-switch type RS485 converter to allow time for the hardware transceiver to switch direction. 4 12.72.4 Configure Quadrature Encoding Set Enhanced Quadrature Encoding for HSC channels (see the PLC's User manual on High Speed Counter hardware for details)

310. Appendix 2 A2-4 T1 T1 A pulse will be sent to Out 5 periodically determined by the Set Value of timer T1 [ δ Cusf] Out5 T1 (Out) (TIM) A2.2 TRiLOGI Sample programs There are many well-documented demos, as well as practi cal TRiLOGI program examples, included in the following TRiLOGI installation folder: <TRiLOGI installation folder>\usr\samples When you click on TRiLOGI’s “File -> Open (Local Drive)” command, you will be able select the user’s folders where pr ogram files are stored. By default, only two users are defined: “Administrator” and “samples” as follow:

209. Chapter 11 11-6 feedback encoder. These hi gh speed counters are a ccessible by CusFn using the variables HSCPV[1] to HSCPV[8]. All HSCPV[n] are 32-bit integer variables. e) Special Variables - Used by EMIT. 4 x special 16 bit integer variables: EM EVENT[1] to EMEVENT[ 4] - emEvent[1] is also used for email purpose. 16 x 16-bit integer variables: EMINT[1] to EMINT[16] 16 x 32-bit integer variables: EMLINT[1] to EMLINT[16] 11.2.4 Integer operators: "Operators" perform mathematical or logical operations on data. TBASIC supports the following integer operators: a) Assignment Operator: An integer variable (A to Z, DM and system variables, etc) may be assigned a value using the assignment statement: A = 1000 X = H*I+J + len(A$) b) Arithmetic Operators: Symbol Operation Example + Addition A = B+C+25 - Subtraction Z = TIME[3]-10 * Multiplication PRINT #1 X*Y / Division X = A/(100+B) MOD Modulus Y = Y MOD 10 c) Bitwise Logical Operators: logical op erations is perform bit-for-bit between two 16-bit integer data. Symbol Operation Example & logical AND IF input[1] & &H02 ... | logical OR output[1] = A | &H08 ^ Exclusive OR A = RELAY[2] ^ B ~ logical NOT A = ~timerPV[1]

76. Chapter 6 6-2 Simply follow the steps below to create your first ladder logic circuit. • Open pull-down "File" menu and select "New". • You should now be in the "Browse" mo de of the logic editor. The vertical line on the left end of the screen is th e "power" line. The cursor is at the position where you can key in your very first ladder logic. You can also view a video version of this tutorial here . 6.1 Ladder Logic Progra mming Tutorial: STEP1 Before we commence the circuit creation, let us define the I/Os to be used for this program. The following I/Os are required: Inputs : Start, Stop, Manual, Step Outputs : Out1, Out2,.... Out8 Relays : Run Timers : Duration Sequencer (counter) : Seq1 1. Click on the button located on right hand side of the upper status bar to open up the I/O label editing Window. You can also achieve the same with the <F2> function key. 2. Scroll to the "Inputs" window by using the left/right cursor keys or by clicking on the red color left/right arrow buttons or simply select it from the choice box be tween the left/right arrow buttons. 3. Move the deep blue color highlight bar to Input #1 position by clicking on it. Click again to open up a text fiel d for entering the name for Input #1.

238. Chapter 12 12-22 Purpose : To return a 16-bit integer data stored in the EEPROM/FRAM by the SAVE_EEP statement, or 8-bi t integer data stored in the FRAM by the SAVE_EEP8 statem ent, or 32-bit integer data stored in the FRAM by the SAVE_EEP32 statement. addr8 - Byte address of EEPROM/FRAM . addr16 - Word address of EEPROM/FRAM . addr32 - Long Word address of EEPROM/FRAM . Please refer to your PLC’s reference manual for the upper limit of available FRAM/EEPROM storage. Byte, Word and Long Word Addressing: Note that the EEPROM space for 8-bit, 16-bi t and 32-bit SAVE_EEPXX and LOAD_EEPXX command are the same space and they are mapped as shown below LOAD_EEP32 LOAD_EEP16 LOAD_EEP8 1 1 and 2 1, 2 3 & 4 2 3 and 4 5,6,7,8 ... ... ... N 2N-1 & 2N 4N-3, 4N-2, 4N-1, 4N If you intend to use the EEPROM/FRAM space to store more than 1 type (8, 16 or 32-bit) of data then you must properly manage the EEPROM/FRAM data space reserved for storing each type of data so that they don't overwrite each other address space. The easiest way is always to reserve enough space for 32-bit data, followed by space reserved for 16-bit and/or 8 bit data. E.g. If you have 6000 words (16-bit) of FRAM space - this means you have space for storing 6000*2 = 12000 bytes of 8- bit data and you only have 6000/2 = 3000 long words for storing 32-bit data. Now assume that your program needs to store up to 500 x 32- bit data and the balance for storing 8 bit data. If you reserve 500 long words for 32-bit data, that means you are using up 500*4 = 2000 bytes of the FRAM space. This

256. Chapter 12 12-40 For Nano-10 and FMD PLCs , you should soft-reset (using the RESET or SETSYSTEM 252, 0 command) and rest art (cold boot) the PLC after changing the DNS address so that the new DNS address will be saved into the virtual EEPROM The PLC will only assume the new IP address after it has been rebooted (via the RESTART command or power-on reset). Example : DM[100] = 192 DM[101] = 168 DM[102] = 1 DM[103] = 101 SET_DNS 100 ‘ Set the DNS address to 192.168.1.101 Note : This command is ignored by i-TRiLOGI simulator. See Also : GET_DNS , SET_SUBNET , SET_GATEWAY , SET_SMTP , SET_IPAddr 12.57 SET_GATEWAY dmindex Purpose : To set the Gateway address of this PLC's built-in Ethernet port using the parameters stored in DM[dmindex] to DM[dmindex+3]. Comments : To change the Gateway address of a PLC's Ethernet port, you can load the new Gateway address into the variables DM[100] to DM[103] (e.g. from a HMI panel) and then invoke a function that runs SET_Gateway 100 to write the new Gateway address into the PLC. For Nano-10 and FMD PLCs , you should soft-reset (using the RESET or SETSYSTEM 252, 0 command) and rest art (cold boot) the PLC after changing the Gateway address so that the new Gateway address will be saved into the virtual EEPROM The PLC will only assume the new Gateway address after it has been rebooted (via the RESTART command or power-on reset). Example : DM[100] = 192

296. Appendix 1 A1-2 Note: The D+ terminal of the U-485 is connected to the + terminal of the PLC RS485 port. The D- terminal of the U-485 is connected to the – terminal of the PLC RS485 port. 2) POWER THE PLC Now that the communication wiring is setup, you can connect power to your PLC. Refer to your PLCs installation gu ide (chapter 1 of the respective user manual) for instructions on powering the PLC. 3) RUN TLSERVER Start TLServer by selecting “ TLServer Version 3.1 ” from “ i-TRiLOGI 6 ” in your PCs start menu (below, top-left screenshot) or by clicking on the quick-launch symbol for TLServer (below, bottom-left screenshot). Once opened, you will see the PLC Webserver window (below, right screenshot): Open TLServer from Start Menu Open TLServer from Quicklaunch TLServer Opened Successfully 4) TLSERVER COMMUNICATION SETUP

308. Appendix 2 A2-2 This will result in an endless loop since th e value of the variable INPUT[1] will never change during execution of the custom function regardless of the actual logic states of physical input #1 to #8. The only way to force upon a physical I/O update is to use the REFRESH command, but it is not a good practice for ladder logic programming to update physical I/Os in the midst of a program execution. The REFRESH command is meant more for forcing an immediate output to be turned ON or OFF during time-critical situations. Hence it is important to allo w a ladder logic program to finish its scan so that the physical I/Os can be updated. You should never hog the CPU within a particular custom function as this will mean the rest of the ladder program don’t have a chance to be executed in a timely manner. A2.1.2 The Difference Between {CusFn} and {dCusF} It is very important to understand t he difference between the two formats of the custom functions once you understand how the ladder logic scanning process works as described in the last section. If you use the {CusFn}, the custom function will be executed EVERY SCAN of the ladder logic program as long as its execution condition is ON. On the other hand, the {dCusF} (known as the differentiated or one-shot format) is executed only ONCE when its execution condition goes from OFF to ON. The execution condition must go OFF and t hen ON again for the function to be executed again. It is not difficult to see that the differentiated format is used far more frequently than the other one since most custom functions involve arithmetic and when a condition is ON yo u most likely want the computation to be performed ONCE and not repeatedly in every scan of the ladder logic. You can easily understand the difference between the two formats if you run the following sample program:

121. Chapter 8 8-15 8.3.2 Connect/Disconnect to Server Use this command to log-in to the TLServ er only if you have no intention to perform other controller commands. You may find that you seldom need to use this command since running the On-Li ne Monitoring or Program Transfer commands will also let you log-in to the TLServer if you have not yet done so. However, once you are connected, th is command changes into "Disconnect from Server" and this is the only wa y for you to log out of the currently connected TLServer so that you can use the Username/Password dialog box to log-in as a different user, or to log-in to another TLServer of a different IP Address/port number. 8.3.3 On-Line Monitoring <Ctrl+M> Refer to the On-Line Monitoring section for details. 8.3.4 Program Transfer to PLC <Ctrl+T> This command is only available if your log-in username is assigned the access level of a "Programmer". If you log-in as a "User" or "Visitor", this command is disabled from the Controller's menu. (It will be enabled again after you disconnect from the server) You can use this command to transfer your i-TRILOGI ladder+TBASIC program into the PLC. You will be prompted to confirm your action to prevent accidentally affecting the target PLC. The ladder program must be compiled successfully before the program transfer process can take place. The progress of the transfer process will be clearly shown on the program transfer dialog box. NOTE: When doing a program transfer, it is now possible to abort a transfer even after the transfer has started. However, the PLC will be left in PAUSE state if a program transfer has been aborted to prevent execution of an incomplete program. NOTE: The Program Transfer window is no w wider to accommodate file names with longer strings and/or in other languages. IMPORTANT: (For Nano-10, FMD88-10, and FMD1616-10 PLCs) If your program is using any timers or counters, you must click ' Reset ' when the program transfer is complete so that the set values are proper ly stored to FLASH memory in the PLC. If you click on 'Close' or 'Reboot' instea d, the set values would not be retained and would be lost when PLC power is tu rned off or cycled unless the program

61. Chapter 4: Using TLServer 4-18 scan these inactive PLCs every two minutes to check whether they have come on-line. If an inactive PLC is found to respond to command it will be unmarked and put back in service for its email request. Test Email You can also manually force the re-scann ing of all PLCs by clicking on the button once. Then scroll to the PLC of interest to check if there is a message. Check the PLC communicati on port wiring if there is an error. This email service period does not dete rmine how often the PLC will send email, since email will only be sent when the emai l request flag is set even if you had set a very short email service period. It only affects how quickly the email will be sent whenever a PLC raises its email flag . You should set a short service period (say every 10 seconds) for urgent email (such as alarm condition). For non urgent email such as hourly or daily production report you can set a much longer servicing period to reduce the communication loads on the PLCs. 4.4.4 Writing i-TRiLOGI Programs that Can Send Emails via TLServer as Email Master In order to send an email, the i-TRiLOG I program needs to use the string variables A$, B$, C$ to store the headers and D$ to Z$ to store the messages. (not all strings need to be used, unused strings are still available for normal program use) The special variable emEVENT[1] is used as an email request flag which should be initialized to -1 when the program is not requesting email service. When the i- TRiLOGI program wants to send an email, it first stores the sender, recipient and subject into the following variables: A$ Sender email address - which can be used to identify the source of the email. B$ Recipient email address - this one must be accurate C$ Subject of the message. D$ First line of Message E$ Second line of email message ... ..... Z$ The 23rd line of the email message emEvent[1] -1 = NOT sending any email. 0 to 23 = number of lines in the email message body which are contained in D$ to Z$.

284. Chapter 12 12-68 See Also : STEPMOVE , STEPMOVEABS , STEPCOUNTABS() , STEPSPEED , STEPSTOP , STEPHOME 12.77 STEPCOUNTABS (ch) Purpose : Returns the absolute positi on of the stepper motor #ch. This function returns a zero if a STEPHOME command had just been executed and the stepper has not been moved since. 12.78 STEPHOME ch Purpose : Set the current position coun ter of stepper # ch to zero. This indicates a new “Home” position of that stepper motor. This command should be executed only when the stepper has reached a particular position to be regarded as the home position. All STEPMOVEABS command executed subsequently will be relative to the defined home position. 12.79 STEPMOVE ch, count, r Purpose : To activate the PLC's built-in stepper motor pulse generator channel #ch to output count number of pulses. The speed and acceleration parameters for the motion is defined by the STEPSPEED statement on the sa me channel # ch, which must be executed at least once before the first STEPMOVE command is issued. After executing the STEPMOVE command the PLC hardware will take over the actual pulse generation operation. The user’s program will continue to execute even though the pulse g eneration is not yet completed. The internal relay #r can be used to signal to the other parts of the ladder program regarding the status of pulse generation, as follow: Parameters : ch = Stepper Channel. Range = 1 to 8 count= Step Count. Range = -2 31 to +2 31 r = Move Complete Relay Bit. Range = 1 to 512

290. Chapter 12 12-74 (Input channel #2 bit #3 = Input 17 +3 = 20) See Also : SETBIT , CLRBIT 12.88 TESTIO (labelname) Note : Please refer to the definition of CLRIO command 12.89 TOGGLEIO labelname Note : Please refer to the definition of CLRIO command 12.90 VAL(x$) Purpose : To return a value of a decimal number contained in the argument x$. Examples : B = VAL("123")*100 Comments : B should contain the value 12300 12.91 WHILE expression .... ENDWHILE Purpose : To execute a series of stat ements in a loop as long as a given condition is true. Syntax : WHILE expression . . . . . . ENDWHILE Comments : When a WHILE statement is encountered, the expression will be evaluated and if the result is true, the statements following the expression will be executed until the ENDWHILE statement. Thereafter, execution branches back to the WHILE statement and the expression is evaluate d again. The loop statements will be executed repeatedly until the expression becomes false.

183. Chapter 10 10-11 memory and you will not be able to un do or abort changes. Hence you can only abort changes to the currently opened custom function before you exit the editor or navigate away to another Custom Function. 10.2.9 #Define Table In previous versions of i-TRiLOGI it was not possible to define variable names for the A-Z, DM[], A$-Z$, etc variables. However, in i-TRiLOGI versions 6.42 and up, a define button has been added to the custom function editor that allows users to create a table of variable and expressi on definitions for all integer/string variables available in TRiLOGI as well as constant values. The next section will describe in details how to use the #Define Table. 10.2.10 Toggle Breakpoint This new debugging aid feature is introd uced since I-TRiLOGI version 6.45. For more information please refer to Section 7. Debugging & Breakpoints 10.2.11 Find Breakpoint This new debugging aid feature is introd uced since I-TRiLOGI version 6.49. For more information please refer to Section 7. Debugging & Breakpoints 10.3 Define Table When the above #Define button is pressed a table of definitions will open as a new window, as shown by the picture on the left below. Only the Label Name and Variable columns can be edited such that the name you would like to use should go in the Label Name column and the name of the variable (eg. DM[1], A, A$, etc.) should go in the Variable column. It is then possible to right-click on any of the cells to bring up the list of options shown by the picture on the right below.

280. Chapter 12 12-64 Applies to the following TBASIC commands or tags (sent via PRINT command), except 255 will only be returned during file access. See the Extended File System chapter of the user manual for more information. READMODBUS, WRITEMODBUS, READMB2, WRITEMB2 I2C_WRITE, I2C_READ <READ>, <WRITE>, <APPEND> tags Example : IF STATUS(2) ‘ MODBUS READ/WRITE OK ... ENDIF 3 0 1 v = 0 : TCP/IP connection closed or last TCP operation failed v = 1 : TCP/IP connection established or last TCP operation successful 4 0 1 2 3 FTP transfer status v = 0 : FTP client was idle or last FTP failed v = 1 : FTP data transfer just started v = 2 : 1st FTP segment transferred, now transferring the rest v = 3 : FTP data transfer completed. Note: only for PLC with firmware r77 and above 5 78 to xx Return the main firmware version xx can be anything higher than 78 E.g.firmware r78A will return 78. Note: only for PLCs with firmware r78 and above 8 0 to 255 Return PLC ID PLC ’ s ID address stored in FRAM/EEPROM for host

3. USER MANUAL Page iii Conditions of Sale and Product Warranty Triangle Research International Inc. (TRi) and the Buyer agree to the following terms and conditions of Sale and Purchase: 1. Triangle Research Programmable Controllers and Peripherals are guaranteed against defects in materials or workmanship for a period of one year from the date of registered purchase. Any unit which is found to be defective will, at the discretion of TRi, be repaired or replaced. 2. TRi will not be responsible for the repair or replacement of any unit damaged by user modification, negligence, abuse, improper installation, or mishandling. 3. TRi is not responsible to the Buyer for any loss or claim of special or consequential damages arising from the use of the product. The products are NOT certified to be FAILSAFE and hence must NOT be used in applications where failure of the product could lead to physical harm or loss of human life . The Buyer is responsible to conduct their own tests to meet the safety regulations of their respective industry. 4. Products distributed, but not manufactured by TRi, carry the full original manufacturers warranty. Such products include, but are not limited to: power supplies, sensors, I/O modules and battery backed RAM. 5. TRi reserves the right to alter any feature or specification at any time. Notes to Buyer : If you disagree with any of the above terms or conditions you should promptly return the unit to the manufacturer or distributor within 30 days from date of purchase for a full refund.

257. Chapter 12 12-41 DM[101] = 168 DM[102] = 1 DM[103] = 1 SET_ GATEWAY 100 ‘Set the Gateway address to 192.168.1.1 Note : This command is ignored by i-TRiLOGI simulator. See Also : GET_GATEWAY , SET_DNS , SET_SUBNET , SET_SMTP , SET_IPAddr 12.58 SET_IPAddr dmindex Purpose : To set the IP address of th is PLC's built-in Ethernet port using the parameters stored in DM[dmindex] to DM[dmindex+4]. Comments : To change the IP addre ss of a PLC's Ethernet port, you can load the new IP address and po rt number into the variables DM[100] to DM[104] (e.g. from a HMI panel) and then invoke a function that runs SET_ IPAddr 100 to write the new IP address into the PLC. For Nano-10 and FMD PLCs , you should soft-reset (using the RESET or SETSYSTEM 252, 0 command) and rest art (cold boot) the PLC after changing the IP address so that the new IP address will be saved into the virtual EEPROM The PLC will only assume the new IP address after it has been rebooted (via the RESTART command or power-on reset). Example : DM[100] = 192 DM[101] = 168 DM[102] = 1 DM[103] = 101 DM[104] = 9080 SET_IPAddr 100 ‘ Set the IP address to 192.168.1.101:9080 Note : This command is ignored by i-TRiLOGI simulator. See Also : GET_IPAddr , SET_DNS , SET_GATEWAY , SET_SMTP , SET_SUBNET

276. Chapter 12 12-60 253 1hh:mm:ss INTRDEF 19, n,1 ' wher e n is the custom function to handle the alarm interrupt. The time and date when the alarm interrupt occurs can be defined using SETSYSTEM 253,data as follow: data = 1hhmmss : set system alarm to occur when the RTC reaches the time "hh:mm:ss" E.g SETSYSTEM 253, 1130500 ' alarm at 13:05:00 When SETSYSTEM 253, 1hhmmss is run the alarm is set on the day when the RTC next reaches hh:mm:ss (so it could be the same day or the next day depending on current time). Applicable only to PLC with firmware r72 and above 254 0 1 2 12.72.19 Ethernet Port Enable data = 0 : Disable Ethernet port to save power - execute only when Ethernet connector is disconnected. data = 1 : (default) Enable Ethernet port. data = 2 : Clear ARP cache so that it will request ARP data before connection. Applicable only to PLC with firmware r74 and above. Note - Do not disable Ethernet port when Ethernet connector is plugged into the switch or router. This is because if Ethernet is disabled while active connection is going on, the CPU can lock itse lf into undefined Interrupt error state. 255 12.72.20 Watchdog Timer This allows you to enable on-CPU Watch Dog Timer.

312. Appendix 2 A2-6 Full scale A/D is 4096. A/D range (0 to 4096) Temperature 0 to 50°C [dCusf] Fn_#1 Clk:1.0 setLCD 1,1, “Temp. Check” ‘ Display at at Column 1, Line1 setLCD 2,1, “Sitting Rm = “+ STR$( ADC(1)*50/4096, 2) +CHR$(223)+”C” Custom Function #1 Comments: Every one second, the special bit Clk:1. 0s closes and activates Function #1. Within the Custom Function #1, ADC(1) reads the A/D converter #1 and converts it into degrees. The integer va lue is then converted into a two-digit string using the STR$ function and concatenated to the rest of the text string for display using the SETLCD command. Simulation of the display string to built-in LCD is supported on TRiLOGI Version 6.x. When in Simulation mode, press <V> key to view the Special Variables and the messages will appear in an LCD Simulation window. A2.2.2 Setting Timer/Counter Set Values (S.V.) Using LCD Display If you have an LCD display, then you can use two push-buttons inputs to change the Set Values (SV) of any selected timers or counters with visual feedback. Assignment: 1. Press push-button “Increase” increment the SV of timer #1 by 0.5s. The upper limit for timer #1 SV is 10s (SV <=100) 2. Press push-button “Decrease” decrement the SV of timer #1 by 0.5s 3. Press “test” button turns ON output #1 for a duration given by timer #1 and then turns it OFF.

286. Chapter 12 12-70 Examples : STEPMOVE 1,5000,10 Send out 5000 pulses on channel 1 and at the end of motion turn ON relay #10. See Also : STEPMOVEABS , STEPCOUNT( ) , STEPCOUNTABS() , STEPSPEED , STEPSTOP , STEPHOME 12.80 STEPMOVEABS ch, position, r Purpose : This command allows you to move the stepper motor # ch to an absolute position indicated by the position parameter. Parameters : ch = Stepper Channel. Range = 1 to 8 position= Step Count. Range = -2 31 to +2 31 r = Move Complete Relay Bit. Range = 1 to 512 Comments : At the end of the move the relay # r will be turned ON. Position can be between -2 31 to +2 31 .(i.e. about ±2 x 10 9 ). The absolute position is calculated with respect to the last move from the “HOME” position. (T he HOME position is set when the STEPHOME command is executed). The speed and acceleration profile are determined by the STEPSPEED command as in the original command set. This command automatically computes the number of pulses and direction required to move the stepper motor to the new position with respect to the current location. The current location can be determined at any time by the STEPCOUNTABS( ) function. Once STEPMOVEABS command is executed, re-execution of this command or the STEPMOVE command will have no effect until the entire motion is completed or aborted by the STEPSTOP command. See Also : STEPCOUNT( ) , STEPCOUNTABS() , STEPSPEED , STEPMOVE , STEPSTOP , STEPHOME

295. Appendix 1 A1-1 A-1 Quick Start: PLC to PC Communication Guide Part 1 of this guide will show how to qu ickly get connected to the PLC from a PC via serial port (RS232 and RS485). Part 2 of this guide will show how to qu ickly get connected to the PLC from a PC via Ethernet port. For a more in depth explanation see chapter 3 INTERFACING TO THE PLC A1.1 Part 1: Serial Communication Setup Guide 1) CONNECT THE PLC TO THE PC VIA SERIAL PORT Choose one of the following two options to connect the PLC to your PC. Note that if your PC requires a USB adapter, it should already be installed at this point. a) Connect via RS232 If you are connecting via RS232 with a USB-RS232 adapter, follow this diagram: b) Connect via RS485 If you are connecting via RS485 with a USB-RS485 adapter, follow this diagram:

300. Appendix 1 A1-6 8) PROGRAM TRANSFER a) Select “Program Transfer to PLC” from the “Controller” menu (or press CTRL +T on the keyboard). b) The “ Login to TLServer ” window will open as shown below. Default Settings: Server IP : localhost – 127.0.0.1:9080 Username : “samples” Password : none (blank field)

210. Chapter 11 11-7 d) Relational Operators : Used exclusiv ely for decision making expression in statement such as IF expression THEN ..... and WHILE expression .... Symbol Operation Example = Equal To IF A = 100 <> Not Equal To WHILE CTR_PV[0]<> 0 > Greater Than IF B > C/(D+10) < Less Than IF TIME[3] < 59 >= Greater Than or Equal To WHILE X >= 10 <= Less Than or Equal To IF DM[I] <= 5678 AND Relational AND IF A>B AND C<=D OR Relational OR IF A<>0 OR B=1000 e) Functional Operators : TBASIC support s a number of built in functions which operate on integer parameters as shown below: ABS(n), ADC(n), CHR$(n), HEX$(n), STR$(n) For detailed explanation of these functi ons please refer to the next chapter: "Programming Language Reference" 11.2.5 Hierarchy of Operators The hierarchy of operators represent the priority of computation. Eg. X = 3 + 40*(5 - 2). The compiler will generate co des to compute 5 - 2 first because the parentheses has the higher hierarchy, the result is then multiplied by 40 because multiplication has a higher priority then addition. Finally 3 will be added to the result. If two operators are of the same hierarchy, then compiler will evaluate from left to right. e.g. X = 5 + 4 - 3. 5+4 is first computed and then 3 will be subtracted. The following table list the hierarchy of various operator used. Hierarchy Symbol Descriptions Highest ( ) Parentheses *, / , MOD Multiplication/Division +, - Add/Subtract - Negate &, |, ^,~ Logical AND,OR,XOR,NOT Lowest =,<>,>,>=,<,<= Relational operators

51. Chapter 4: Using TLServer 4-8 the corresponding error messages in the response box. Click on the "Hang Up" button anytime to abort the dialing operation. If you click on the "Special" button a special dialog box will appear as follow: • You can change the DTE speed by selecting a new value from the choice menu. • You can specify a special AT command to be sent to the modem during modem initialization. Normally you can leave this field to its default value which is AT&K0. • You can also specify a special "Call-in Password" which is only used if the TLServer puts itself in auto-answer mode (see description later). Any incoming connection made by a remote modem must give the correct password upon connection, otherwise the connection will be immediately dropped. The Call-In password feature is disabled if the corresponding textbox is empty. 2. Auto Answer: If you select the "Auto Answer" checkbox and click on the "Connect" button, the TLServer will setu p the modem to automatically answer the incoming call on the first ring. There are many uses of this capability: • Any number of PLCs in the field can peri odically dial in to a single TLServer and write or append the values of their internal variables to data files on the PC's hard disk using the PLC File Service commands. This is extremely useful for deploying the PLC for da ta-acquisition purposes. You can format the data using CSV format so th at the file can be readily imported into an MS Excel or Lotus 123 spreadsheet. • The remote PLC can dial in and ask TL Server to send out its data to any email address immediately. • The remote PLC can dial in and synchr onize its real time clock with the TLServer. • The TLServer can play the role of an ISP where the PLC can dial in and be accessible to the Internet.

305. Appendix 1 A1-11 b) The “ Login to TLServer ” window will open as shown below. Note that in this case TRiLOGI will login to the PLCs FServer, even though it displays Login to TLServer. Default Settings: PLC IP : 192.168.1.5:9080 Username : none (ignored) Password : none (ignored) c) Enter the IP address and port number of your PLC if it was changed from the default: 192.168.1.5:9080 d) Follow steps c-h in the Program Transfer section from Part 1 of this guide. 5) ONLINE MONITORING Follow the steps in the ONLINE MONITORING section from Part 1 of this guide.

323. Appendix 3 A3-1 A-3 Troubleshooting Serial Communication If you are unable to communicate with the PLC from TRiLOGI, first check the following: 1. TLServer is Running . This is required for serial communication to work. Refer to chapter 1.5 Run TRiLOGI and TLServer for instructions on starting TLServer 2. The PLC is powered on and properly connected to the PC . Refer to A1.1 Part 1: Serial Communication Setup Guide for serial port connection info. Refer to your PLCs installation guid e (chapter 1 of the respective user manual) for instructions on powering the PLC. 3. The Correct COM port is selected in TLServer . Refer to section 4) TLSERVER COMMUNICATION SETUP in the A1.1 Part 1: Serial Communication Setup Guide for instructions on selecting the correct com port. 4. The USB to serial converter is properly installed . If the adapter is not listed in your PCs device manager, as shown in the TLSERVER COMMUNICATION SETUP section referenced above, then t he adapter driver may still need to be installed. Refer to the CD/installati on instructions provided with the USB adapter. Once installed, make sure to restart TLServer if it was left open. 5. The PLC program is not using the serial port . If the PLC program is trying to send data out of the serial port, then it will corru pt communication attempts from TRiLOGI/TLServer and would not work. It is possible to pause the PLC using DIP Switch #4 on the bl ue switch box that is physically located on the PLC (Note that it is jumper J4 for the Nano-10 PLC). The PLC should be power cycled after being paused, which will bypass any program initialization function th at could affect the default PLC communication settings. TL Server can be set to t he default com settings: 38,400 bps, 8 data bits, 1 stop bit, no parity and communication can be reattempted. Refer to chapter 1.8.1 of your PLCs user manual for more information on this. If communication is still not possible at th is point, please contact tech support by phone at 877 874 7527 or by email at support@tri-plc.com.

2. USER MANUAL Page ii Copyright Notice and Disclaimer All rights reserved. With the exception of legitimate TRi PLC users, who may print or make copies of this manual for reference purposes, no parts of this manual may be reproduced in any form without the express written permission of TRi. Triangle Research International, Inc. (TRi) makes no representations or warranties with respect to the contents hereof. In addition, information contained herein are subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, TRi assumes no responsibility for errors or omissions or any damages resulting from the use of the information contained in this publication. Windows is a trademark of Microsoft Inc. MODBUS is a trademark of Mobdus.org All other trademarks belong to their respective owners. Revision Sheet Release No. Date Revision Description Rev. 1 3/14/2013 Complete Update of all chapters for synchronization with TRiLOGI version 6.45 build 06 Rev. 1.1 5/03/2013 Added notes on using RESET and SETSYTEM 252,0 commands and performing a ‘Reset’ after program transfer to backup timer & counter set value data. Rev. 1.2 6/27/2013 Fixed TESTIO example that previously referenced TESTBIT Rev. 1.3 7/15/2014 Added ELSEIF an d ELIF commands to chapter 12 Rev. 1.4 8/27/2014 Added SET_SUBNET, SET_GATEWAY, SET_DNS, SET_SMTP, GET_IPADDR, GET_SUBNET, GET_GATEWAY, GET_DNS, GET_SMTP commands to chapter 12. Added find and replace feature, row and col position of the cursor, and a Find Breakpoints button within the custom function editor to chapters 10.2 and 10.7

63. Chapter 4: Using TLServer 4-20 10, FMD series, and F-series PLCs can also perform these file and email services via TCP/IP from their built-in FServer, which is described in the Network Services section of the PLC user manual (chapter 2. 3). This section will only describe how to do such tasks with TLServer, so the FServer would only be referenced when the TLServer is being used to make a connection to it. Basically, a PLC can send serv ice requests to the TLServer using "tags" (which are ASCII characters enclosed between the '<' and '>' characters) and the TLServer will perform the service requests upon receiving valid commands. All data between the <command [parameter]> tag and the </> tag will be treated as data for the requested service. Since the PLC is the one that initiates the service reques t, it does not need to be linked to the TLServer all the time, only when it needs to re quest a service from the TLServer. This makes it possible for a remote PLC to connect to the TLServer, via the telephone line and modem to perform the required file or email services, then disconnects itself from the TLServer so that other PLCs can take turns to connect to the TLServer to request for services. Note : All the files created or used in th e write/append/read actions are located in the directory: <trilogi base directory> /FileService. (Hence the default path is C:\TRiLOGI\TL6\FileService). You may also read/write files that are located in the sub-directory below the "..../FileService" directory provided that the sub- directory already exists. The currently supported files and emails services are described below: 1. Write data to file. Format: <WRITE [filename]> data data data... data .... </> E.g. To save data of DM[1] to DM[10] to a file name "testWrite.txt", execute the following statement from a custom function: PRINT #1 "<WRITE testWrite.txt>" ' Write data request FOR I = 1 TO 10 PRINT #1 DM[I];" "; REM delimited by space characters. NEXT PRINT #1 ' send a CR character. PRINT #1 "</>" ' End of Service request The TLServer will close the file after it receives the end-of- service tag "</>" from the PLC and it will in turn send a "<OK>" string to the PLC to acknowledge that the WRITE request has been completed successfully. It is up to your PLC program to check for the " <OK> " tag to determine if

68. Chapter 4: Using TLServer 4-25 read or write data to the remote PLC as if the remote PLC is on the same local network. Multiple NETCMD$ commands can be executed but there should not be more th an 2 seconds delay between each command. This is because If the FServer does not receive any serial string from the PLC for more than 2 seconds it will terminate the <CONNECT> session automatically. Once the command exchange has been completed, you’ll send a </> tag to end the connection gracefully. Note: similar to local RS485 communicati on, the source PLC that talks across the network using the <CONNECT> service should have a different ID (00 to FF) from the target PLC that it is trying to talk to. E.g. A PLC with ID=01 should not talk to another PLC with ID=01 even though the other PLC is connected to a remote server. By changing the ID of one of them, you will avoi d the problem of a response string from the other PLC being misinterpreted by the sending PLC as an incoming host link command. Examples of using the <CONNECT> tags with TLServer can be found in the TestEthernet.PC6 sample program in the following folder: "C:\TRiLOGI\TL6\usr\samples\TLServer" Note: Your version of TRiLOGI may have the previous folder address, as shown below, but the PLC program is the same. "C:\TRiLOGI\TL6\usr\samples\XServer"

273. Chapter 12 12-57 11 0 1 to +127 -1 to -127 12.72.9 Calibrate RTC Add or subtract data seconds per day from the RTC to calibrate it for accuracy. E.g. if the clock is 3 seconds too slow everyday, then run SETSYSTEM 11, 3 once during 1st.Scan and the CPU will increase the RTC by +3 seconds every time when it past midnight. data = -127 to +127 to adjust the RTC for accuracy after midnight. data = 0 : (default), no adjustment data > 0 : RTC crossover from 23:59:59 to 0:0:data directly and bypasses 0:0:0. E.g. data = 5, clock is adjusted faster by 5 seconds. data < 0 : RTC stop at 23:59:59 and wait until (-data) seconds later then cross over to 0:0:0 E.g. if data = -5, the RTC is slowed by 5 seconds. Applicable only to PLC with firmware r78 and above 16 3 to 16 12.72.10 Number of I/O to Support Total number of 8-bit digital I/O channel supported. data = d => (d x 8) inputs and (d x 8) outputs. E.G. data = 16 (default) => 16 x 8 = 128 Inputs and 128 outputs. If you don't use expansion board, and if you run SETSYSTEM 16, 3 then only inputs 1-24 and outputs 1-24 will be accessed during I/O scan . This can reduce the I/O scan time. Otherwise the defaul t is to scan all 128 inputs and 128 outputs which consumes 0.5ms on an F-series PLC. 17 0 12.72.11 Enable IR Remote data = 0 : disable IR Remote (default)

200. Chapter 10 10-28 and a pop-up message window reports to you the cause of the error. You can then immediately fix the error and re-comp ile until all the errors have been corrected. Error Message Cause / Action Undefined symbol found Only TBASIC commands and legal variable names are allowed. See Chapter 3. Compiler internal error Serious trouble, please email to the manufacturer support@tri-plc.com to inform us. " ) " found without matching " ( " - Integer expected Expect to see either an integer variable or integer constant. Value is out-of-range Check the language reference for allowable range of values for the command. Duplicate line label number Label for goto must be unique within the same CusFn. Undefined GOTO destination: Put a ma tching label at the place where the GOTO statement is supposed to go. Invalid GOTO label @# must be in the range 0-255 Type mismatch (numeric and string types may not mix) In an expression, string s and integers may not be mixed unless converted using the conversion function. e.g. STR$, VAL, etc. String is too long A string is limited to 70 characters Too many line labels There should not be more than 20 GOTO labels within the same CusFn. Unknown Keyword Most likely wrong spelling for TBASIC statement or function. WHILE without ENDWHILE Every WHILE statement must be ended with a matching ENDWHILE statement. Nested WHILE loop must have proper matching ENDWHILE for each WHILE. IF without ENDIF Every IF statement must be ended with a matching ENDIF statement to define the boundaries for the block controlled by the IF statement. For multiple IF THEN statement, each IF must be matched by a corresponding ENDIF. FOR without NEXT Every FOR statement must be ended with a matching NEXT statement to define the boundaries for the block controlled b y the

282. Chapter 12 12-66 Note : only for PLC with firmware r78 and above 17 IR Code Return IR Code Specific only to F-series PLC with Infra-Red decoder. Returns the decoded IR remote code. See chapter 17 of the user manual for more details. Note: the SETSYSTEM 17, 1 command must be executed first to enable the IR decoder. 18 000000 to 235959 Return Time as Integer Return current Real Time Clock value as a 6 digit integer from 000000 to 235959 Must be returned to a 32-bit variable. Example: At 00:12:05 => A = STATUS(18) returns 001205 to A. At 12:00:05 => A = STATUS(18) returns 120005 to A. Note: Only for PLCs with firmware r72 and above. 19 Return File Length Return the file length of the currently opened file. Example: The currently open is 50kb => A = STATUS(19) returns 50000 to A. See the Extended File System chapter in the PLC user manual for more information. Note: only for PLCs with firmware r77 or above 20 >= 0 < 0 FTP transfer status v >= 0 : Number of bytes uploaded to FTP Server. Transfer is in progress. v < 0 : Total number of bytes uploaded. Transfer completed.

65. Chapter 4: Using TLServer 4-22 Subject: [subject text] data data data... data .... </> PLC" PRINT #1 "Don't worry, everyting is working out great today!" PRINT #1 </> Note: • "Sender:" field should be in email format such as xxx@yyy.zzz, but it does not need be a valid email address. • "Subject:” field is optional and may be omitted totally • The TLServer will first save a ll the data it received into a temporary file named "Email.txt" in the default directory. After the TLServer receives the end-of- service tag "</>" from the PLC and it will then send out the email to the recipient email address. This email service will make use of the SMTP server defined in the "Setup Emails" portion of the TLServer configuration, so make sure that you have defined a correct SMTP server before testing the email service function. When the email has been successf ully sent via the SMTP server, the TLServer will send an "<OK>" tag to the PLC to acknowledge that the EMAIL request has been successfully completed. It is up to your PLC program to check for the "<OK>" tag to de termine if it the service it requested has been processed. 4. Read Data from File. Format: <READ [filename]> </> This service allows the PLC to request the TLServer to open a text file and upload its content to the PLC. This may be useful for loading some previously saved parameters. Upon receiving this command and if the specified [filename] is successfully opened, the TLServer will begin sending all the ASCII ch aracters contained in the text file to the PLC. Note that line breaks in a text file are sent to the PLC as CR character only and not as a CR+LF pair. As such, your PLC program can easily use the INPUT$(1) command to read in all the CR

309. Appendix 2 A2-3 [ δ Cusf] Fn_#1 Clk1.0s Fn_#2 Clk1.0s A = A+1 Custom Function #1 {Cusfn} {dCusf} B = B+1 Custom Function #2 Run the program in simulator and press t he <V> key to view the changes in the variables A and B. You will see that B is incremented by one every second, while A is incremented wildly for 0.5s and then stops for 0.5s. Try it! It can be very educational! If you want to periodically check the stat us of an analog input or the real time clock, you should use a clock pulse (0.1s, 1.0s etc as shown in the example) and connect to a {dCusF} . Connecting to non-differentiated version would mean checking thousands of times for half the period and not at all for the other half period -- certainly not the intended outcome. A2.1.3 Timers Contact Updating Process All the timers' contacts of the PLC, li ke the inputs and outputs, are updated simultaneously at the beginning of ever y ladder logic scan and not at the rung that contains the (TIM) coil. So if you are us ing self-reset timer, please note that if a timer times out its contact will be ON from the beginning of the ladder logic rung until the rung that contains the se lf-reset circuit. Thereafter the timer contact will be OPEN since the coil has been self-reset. Hence please note that you should place the self-reset timer rung after all the ladder rungs that utilize the said timer contact . This allows those ladder rungs which use the timer contact to have a chance of being executed before the self-resetting rung clears the timer.

201. Chapter 10 10-29 FOR statement. For nested FOR loops, each FOR must be matched by a corresponding NEXT. Expect keyword "TO" Required by FOR statement. Must be an integer String variable or constant not allowed. Must be an integer variable only Integer constant not allowed. Must be an integer constant only Integer variable not allowed. Must be a string Integer constant or variable not allowed. Must be a string variable only String constant not allowed. Must be a string constant only String variable not allowed. Incomplete Expression Expression not ended properly. String constant missing closing " String constants must be enclosed between a pair of opening and closing quotation character (") Must be Integer A to Z only index for FOR..NEXT loop must be A-Z. 10.8.2 Run-Time Errors Certain errors only become apparent duri ng the execution of the program, e.g. A = B/C . This expression is perfectly OK except when C = 0, then you would have attempted to divide a number by zero, which does not yield any meaningful result. In this case a "run-tim e error" is said to have occurred. Since run-time errors cannot be identified du ring compilation, i-TRiLOGI also checks the validity of a command during simula tion run and if a run-time error is encountered, a pop-up message window will report to the programmer the cause and the CusFn where the run-time error took place. This helps the programmer locate the cause of the run-ti me errors to enable debugging. The possible run-time errors are listed in the following table and they are generally self-explanatory. Run-Time Error Message Divide by zero Call stack overflow! Circular CALL suspected! FOR-NEXT loop with STEP = 0! SET_BIT position out-of-range! CLR_BIT position out-of-range! TEST_BIT position out-of-range! STEPSPEED channel out-of-range! Illegal Pulse Rate for STEPMOVE!

271. Chapter 12 12-55 5 0 d 12.72.5 DM[]s Cleared During Reset data = 0 : All DM cleared when PLC is soft-reset. data = d : DM #1 to #d will not be cleared when the PLC is soft-reset. NOTE: Applicable only to PLC with firmware r78 and above. 6 3 4 6 d 12.72.6 Modbus Function Select data = 3 : READMODBUS and READMB2 use Modbus Function 03. WRITEMODBUS uses default (function 16) data = 4 : READMODBUS and READMB2 use Modbus Function 04. WRITEMODBUS uses default (function 16) The following is applicable for PLC with firmware r77 and above only: data = 6 : WRITEMODBUS uses Modbus Function 06. READMODBUS and READMB2 uses default (function 03) data = d : Any other values of data (d) will set READMODBUS and WRITEMODBUS back to default (03 for READ, 16 for WRITE) 7 Reserved 8 d 12.72.7 Change ID Allow the PLC to change its own ID from within TBASIC temporarily to the lower 8-bit value provided in the "data" parameter for individual COMM port. The new ID is volatile. It does not overwrite the default PLC ID which can only be changed from a host program using the "IWxx" command. SETSYSTEM 8, n COMM1: d = &H0001 to &H00FF

268. Chapter 12 12-52 1 dd dd dd dd 12.72.1 Com Response Wait Time The data value determines the # of wait states (multiple of 0.15s for serial and 0.20s for Ethernet*) to wait for a response from a slave controller after executing a NETCMD$, READMODBUS, WRITEMODBUS, READMB2 or WRITEMB2 command. *Note: For PLCs with firmware before r77, the Ethernet port wait time is a multiple of 0.5s inst ead of 0.2s, which is for PLCs with firmware r77 or higher. The serial wait time is 0.15s for all firmware versions. For Nano-10, FMD and F-series PLCs Only SETSYSTEM 1, data affects the 4 COMM ports (COMM4 is Ethernet client connection) individually, where bit 0 & 1 are for COMM1, bit 2 & 3 are for COMM2 , bit 4&5 are for COMM3 and bit 6&7 are for COMM4. By default data is set to &H55 (binary 01 01 01 01), which means a 2 wait multiple is used for all 4 COMM ports. This is about 0.30s for all 3 serial COMM ports, and about 0.40s the Ethernet port (PLCs with r77 or higher firmware). Bit # 76 54 32 10 data dd dd dd dd Comm port 4 3 2 1 dd = 00 01 10 11 # of Wait States 1 2 3 4 Note: maximum = 4 retries In order to change the wait states for COMM3 you have to set the bit 4 & 5 of data. E.g SETSYSTEM 1, &HFF This will change all 4 COMM ports to wait for 4 cycles ( 0.60s for serial p ort and 0.80s for PLCs with firmware r77 or

38. Chapter 3 3-10 FServer). Connect via serial port to TLServer Connect via Ethernet to FServer Default Settings: Server IP : localhost – 127.0.0.1:9080 Username : “samples” Password : none (blank field) Default Settings: Server IP : 192.168.1.5:9080 Username : none (ignored) Password : none (ignored) The above-left screenshot is the default co nfiguration, which is set to login to TLServer using the “ localhost – 127.0.0.1:9080 ” option. The default Username is “ samples ” with no password required. Use this configuration if you are connected via serial port and if TRiL OGI is running on the same PC as TLServer. The above-right screenshot is an exampl e of a configuration used to connect to FServer using a specified IP address and port number. In this example, the default PLC IP address (192.168.1.5) and port number (9080) is specified, but these should be replaced by the ac tual IP address and port number configured in your PLC. There is no username and password set for Ethernet communication by default, so these fi elds can contain an ything since they will be ignored. 3. After configuring the login settings, you will need to click “Detect ID” and the PLC ID should be returned in the adjacent field, as shown below, if communication is functioning correctly.

319. Appendix 2 A2-13 represented by 160, -10.0°C is represented by -100. This method, known as fixed- point computation is quite commonly used in industrial control program. A2.2.7 Closed-Loop PID Control of Heating Process PID Controller Burner A /D#1 Sensor D/A #1 E.g. Implementing Closed-loop Digital Control with PID computation function A /D#5 PID Controller Transfer Function: G(s) = KP + K I s + KD s K P = Proportional Gain = 1 Proportional Band K I = Integral Gain = 1 Integral Time Constant Assignment: 1. Read desired set-point temperature from a potentiometer connected to A/D #5 (S) with temperature range between 50 oC - 200 oC 2. Measure the process temperature from a thermocouple + signal conditioner attached to A/D #1(T) 3. Compute the Error = S - T. Apply Proportional + Integral + Derivative (P.I.D) algorithm to compute output X. 4. Apply output X to Digital-to-Ana log converter D/A #1 to control a variable position valve that feed fuel to the flame. 5. Sample and compute every 1 second. Full scale A/D range is 4096 Range of Set Point: A/D #5 = 0 +50.0 °C

67. Chapter 4: Using TLServer 4-24 If error occurred: ERR: (description of error) This command does not require a </> to close the tag. 7. Connect to Remote TLServer or FServer using NETCMD$ Format: <CONNECT [IP address:port of TLServer or FServer]> [username string] [password string] TLServer replies with “<CONNECTED>” if successful or “ERR:...” if error encountered [host link command 1] TLServer sends the host link command to a remote TLserver or FServer and return the response to the PLC. [host link command 2] TLServer send the host link command to remote TLServer or FServer and return the response to the PLC. ..... </> Description: This service enables a 'Sup er' PLC to communicate with other PLCs via TCP/IP protocol usin g the TLServer and FServer or any combination of these. It allows yo ur PLC to login to another remote TLServer or FServer via the LAN or the Internet and your PLC can then use the NETCMD$ command to exchange data with the PLC(s) that are connected to that remote server. You execute this command by first sending the string <CONNECT xxx.xxx.xxx.xxx:9080 > to the TLServer where xxx.xxx.xxx.xxx is the IP address of the remote TLServer or FServer. Then followed by the username and password needed to lo gin to the remote server. Once the connection is established, the TLServer will return the response string <CONNECTED> to the PLC. When the PLC receive the <CONNECTED> string it can use the TBASIC “ NETCMD$ ” command to

281. Chapter 12 12-65 communication. Returned as an integer in the range 0- 255 decimal or 00-FF Hex. Note: if the ID is changed, a cold boot (power cycle) is required for STATUS(8) to return the new ID. Otherwise the previous ID is returned. 14 0 to 64 Ethernet Connection Status A byte is returned and each of the first 7 bits represent a connection state for an incoming or outgoing Ethernet connection. Bit7 (MSB) is not used and can be ignored. Bit# 6 5 4 3 2 1 0 State 1 0 1 0 1 0 1 0 1 0 1 0 1 0 Connection Type (Default) Client MDBTCP MDBTCP MDBTCP FSERVER FSERVER FSERVER Note: Bit 6 will always represent the PLCs 1 client connection (outgoing), bits 4 and 5 will always represent Modbus TCP (incoming), and bit 0 will always represent an FSERVER connection (incoming). Bits 1,2, and 3 can be set to either type (view chapter 2 of the PLC user manual for more details). By default, there are 3 incoming connections for each type. If any bit is set to ‘1’, that means the corresponding connection type is being used and is not available. Any bits set to ‘0’ are free to be used (available connections). Example: STATUS(14) returns 11 => bits 0, 1, and 3 are on Comment: 2 of 3 incoming FSERVER connections are used. 1 of 3 incoming MDBTCP connections are used.

314. Appendix 2 A2-8 A cheap potentiometer can be connected to the PLC A/D input and provide a user-adjustable “knob” as an analog “S et Point” input devi ce. A scale can be drawn around the potentiometer to provide visual indication of set point value. Assignment: 1. A potentiometer is connected to A/D #5. Use it to provide a timing range of 0 to 10.00 seconds. 2. Pressing the “test” input turns ON ou tput #1 for a duration determined by the potentiometer reading, after that turns output #1 OFF. Test Tim1 Out1 Fn_#10 Test Out1 Tim1 [dCusf] (OUT) (TIM) HSTIMER 1 ‘ Define Timer #1 as High Speed Timer (0.01s base) TimerPV[1] = ADC(1)*1000/4096 ‘ Set the timer running with ‘ value proportional to A/D value. Custom Function #10 Comments: To take full advantage of the resolution of the A/D converter, the timing range of 0-10 seconds is more finely divided w hen timer is defined as high-speed timer using the HSTIMER command. The time base is now 0.01s. This means that for maximum value of 10.00s, the timer should count down from 1000. The next statement in CusFn #10 comput es the ratio of the A/D input with respect to its full scale value of 4096 and multiplies it to the maximum timing value of 1000. I.e., if t he potentiometer wiper is at half way, the A/D reading will be around 2048, the computation will results in a timing value = 2048*1000/4096 = 500, or 5.00 second. Note that TRiLOGI 6.x does not support floating-point arithmetic. Hence the multiplication mu st be carried out before the division . Otherwise, if you compute 2048/4096 *1000, the result of the integer division of 2048/4096 = 0 and the whole expression yields a ‘0’, which is clearly wrong!

274. Chapter 12 12-58 1 data = 1 : enable IR Remote Note: Only applicable to F-series PLCs (F2424 and F1616- BA). See users manual for more details. 20 0 1 2 to 255 12.72.12 Pulse Measurement Resolution data = 0 : PULSEPERIOD and PULSEWIDTH 1 to 4 returns data with 0.1us resolution data = 1 : PUSLEPERIOD and PULSEWIDTH 1 to 4 returns data with 1us resolution. (For PLC firmware r77 and above) data = 2 to 255 : Number of seconds of inactive incoming pulses before PULSEWIDTH and PULSEFREQUENCY assume that incoming pulses has stopped. Default is 5 seconds. 22 0 1 12.72.13 Dimmer Interrupt Enable data = 0 : Disable Dimmer interrupt data = 1 : Enable Dimmer interrupt 24 UB LB 12.72.14 Quadrature Encoder Config data is defined as a two-byte integer for configuring the HSC channel to be simple, enhanced x1, enhanced x2 or enhanced x4 count. (Applicable only to PLC with firmware r72 and above). Upper byte (UB): channel number (&H01 or &H02 or &H03) Lower byte (LB) : &H00 (default) =simple ; &H01=x1; &H02=x2; &H03= x4 View the HSC chapter of your PLCs reference manual for more information. 25 12.72.15 Analog Output Range

318. Appendix 2 A2-12 1. Read desired temperature setting (S) from a potentiometer connected to A/D #5. 2. Read current air temperature (T) from sensor attached to A/D #1 (T) 3. Turn ON cold air-conditioner (output #1 with labelname: OUT1) if T > S by more than 1.5 oC. 4. ON heater if (output #2) if S > T by more than 1.5 oC. 5. Turn OFF both heater and cold air-conditioner if T is within + 1.5 oC of S. Parameters: Full scale A/D is 4096 Range of Set Point: A/D #5 = 0 +16.0 °C A/D #5 = 4096 +30.0 °C Range of Sensor: ADC#1 = 0 -10.0 °C ADC#1 = 4096 +50.0 °C [ dCusf ] Fn_#20 Clk:1.0 S = ADC(5)*(300-160)/4096 +160 ‘Convert to o Cx10 T = ADC(1)*(500+100)/4096 -100 ‘Convert to o Cx10 IF S -T > 15 SETIO OUT1 ‘Cold Air-conditioning ON ELSE CLRIO OUT1 ‘if T is hotter by 1.5 o C ENDIF IF S-T < -15 SETBIT OUTPUT[1],1 ‘ Heater ON ELSE CLRBIT OUTPUT[1],1 ‘if T is colder by 1.5 o C ENDIF Custom Function #20 Comments: Since TRiLOGI Version 6.x does not support floating point computation, in order to handle decimal value (±1.5° C) in th is application we use a unit integer to represent 0.1 quantity. All temperature readings are x10 times. Hence 16.0°C is

275. Chapter 12 12-59 Applicable only to FMD PLCs for selecting the analog output type (0-5V or 0-10V). Please refer to Chapter 5 of the PLC's User Manual. 251 0 to 5 11 12.72.16 Close TCP Connection To force close an an incoming TCP server connection. data = 0 to 5 : Force-close a FServer and Modbus/TCP server connection data = 11 : Force-close a FTP Server connection. Applicable only to PLC with firmware r78 and above 252 0 12.72.17 Write to Flash data = 0 : On Nano-10 and FMD PLC without the FRAM- RTC, this command is used to force save the emulated EEPROM content to the CPU Flash memory. Important: This command should be executed every time a SETTIMERSV , SETCTRSV , or SET_IPADDR command is used so that the data is properly backed up to PLC FLASH memory. This must be done for all Nano-10 and FMD series PLCs with or without any FRAM-RTC module installed. 253 0 1 2 12.72.18 Control the RTC operation. data = 0 : Completely disable the RTC on the CPU data = 1 : (default) Enable the RTC on the CPU data = 2 : Disable hourly auto update of RTC data from FRAM-RTC (useful on systems that rely on RTC update from Internet Time Server) You can also use this command to setup the date and time for an RTC alarm interrupt to occur. The interrupt handler can be defined using

64. Chapter 4: Using TLServer 4-21 the service it requested have been completed successfully. 2. Append data to file Format: <APPEND [filename]> data data data... data....</> E.g. To append the time of an event to a file name "testAppend.txt", execute th e following statements in a custom function when the event take place: PRINT #1 "<APPEND testAppend.txt>" ' Append data request PRINT #1 "Event Time = ";TI ME[1];":";TIME[2];":";TIME[3] PRINT #1 "A=";A PRINT #1 "</>" ' End of Service request • If the file does not exist a new file will be created. Otherwise, the PLC's real time clock data in the format "hh:mm:ss" and the value of A will be appended at the end of the file "testAppend.txt" every time the above statements are executed. • The TLServer will close the file after it receives the end- of-service tag "</>" from th e PLC and it will in turn send a "<OK>" tag to the PLC to acknowledge that the APPEND request has been successfully completed. It is up to your PLC program to check for the "<OK>" tag to determine if it the service it requested have been completed successfully. 3. Email data to recipient Format: <EMAIL [email address]> Sender: [sender email] E.g. To send data to an email address: whoever@yahoo.com with the subject "PLC Email Test", execute the following statements: PRINT #1 "<EMAIL whoever@yahoo.com>" ' change it to your own email. PRINT #1 "Sender: triuser@hotmail.com" ' it can be anything. PRINT #1 "Subject: PLC Email Test" PRINT #1 " Hello this email is sent by your friendly TRiL OGI

12. USER MANUAL Page xii A2.2.5   Activate Events at Sc heduled Date and Time ..................................................... 2-10   A2.2.6   HVAC (Heating, Ventilation an d Air-Conditioni ng) Control ............................... 2-11   A2.2.7   Closed-Loop PID Control of Heating Process ....................................................... 2-13   A-3   TROUBLESHOOTING SERIAL COMMUNICATION 3-1   A-4   PLC-TO-MODEM COMMUNICATION SETUP 4-1   A4.1   Modem Connection.................................................................................... 4-1   A4.2   Communication Speed .............................................................................. 4-2   A4.3   Software and Programming ....................................................................... 4-3  

66. Chapter 4: Using TLServer 4-23 terminated text string one string at a time and then interpret or convert the data as necessary. After sending out the last byte in t he data file to the PLC, the TLServer will send a CR-terminated acknowledgement string "<OK>" to the PLC to signal that the READ command has been properly completed. 5. Read Real Time Clock From TLServer Format: <READ RTC[]> </> <READ Date[n]> </> where n = 1,2,3,4 <READ Time[m]> </> where m=1,2,3. This service allows the PLC to get the Real Time Clock data of the TLServer (i.e. the PC in which the TLServer runs on). The type of data is indi cated in the Date[n] and Time[n] parameter which correspond to the DATE[n] and TIME[n] system variables in TBASIC: i.e. Date[1] = year; Date[2]=month; Date[3]=day; Date[4]=DayofWeek; Time[1]=hour; Time[2]=minute; Time[3]=second. For full synchronization, use the <READ RTC[]> tag which returns the values of the Date[1], Date[2], Date[3], Date[4], Time[1], Time[2], Time[3] in 7 CR- terminated ASCII strings. Upon receiving this command the TLServer will immediately send the relevant clock/calendar data as CR-terminated ASCII string (s) to the PLC. Your PLC program can easily use the INPUT$(1) command to read in the data and convert them into integers using the VAL command. Note that unlike the "READ file" service, the TLServer does not send "<OK>" string after performing the "READ RTC" service. 6. Get IP Address Format: <IP> This command allows the PLC to query the TLServer’s IP address. Upon receiving this command, the TLServer will send the following response string: If successful: xxx.xxx.xxx.xxx :nnnn (IP address:port of TLServer)

27. Chapter 2 – Introduction To I-TRiLOGI 2-3 2.3 i-TRiLOGI Application vs Applet: Which is Better? Pros Cons Application • Starts up immediately. • Can read/write TRiLOGI files to local hard disk or to TLServer. • Can access any TLServer on the network. • Program behavior predictable since the copy of JVM is local. • Require local installation of TRiLOGI software at every client computer. • Require installation of JVM at every client computer. • May need to specify the proxy server IP address if running behind a firewall. Applet • No need to install any software or JVM at the client computer. • Possible to control your PLC via any CyberCafe or at a friend's house! • Maintenance and Upgrading of software is simple since only one copy of the TL6x.jar file needs to be changed. • Centralised storage of program files only at the server. This is good for providing PLC program training. • Can only read/write TRiLOGI files to the TLServer but not to the local hard disk. • Can only access the TLServer from which it was loaded. • May take a few minutes to load itself the first time if connect via dial up modem. (Thereafter the browser should cache it for rapid start up.) • Program behavior may vary for different make or different versions of the browser.

317. Appendix 2 A2-11 3. On 1st Jan 2000 at 12:00 turn ON output #5. 4. On the same day at 18:00 turn OFF output #5 ( TIM ) Tim30s Tim30s IF TIME[1]=19 AND TIME[2]=0 ‘ Hour hand at 19 SETIO OUT1 ‘ Minute hand at 00 ELSE IF TIME[1]=7 AND TIME[2]=0 CLRIO OUT1 ENDIF ENDIF IF DATE[1]=2000 AND DATE[2]=1 ‘Jan, yr 2000 IF DATE[3]=1 IF TIME[1]=12 SETBIT OUTPUT[1],4:ENDIF IF TIME[1]=18 CLRBIT OUTPUT[1],4:ENDIF ENDIF ENDIF Custom Function #1 [ dCusf ] Fn_#1 Tim30s Comments: 1) Tim30s should have a Set Value = 300 and it activates Function #1 every 30 seconds. It is not necessary to c heck the clock too often as checking consume CPU execution cycles. 2) We used SETIO to control Output #1, but as a demonstration we use SETBIT to control Output #5 which is bit #4 of the variable OUTPUT[1]. The statement SETBIT output[1],4 turns ON output 5. 3) Actually it may not be necessary to check the minute hand since when the RTC turns from 18:59 to 19:00, the output will be turned ON as long as TIME[1]=19. Only when TIME[1]=7, then output #1 needs to be changed. A2.2.6 HVAC (Heating, Ventilation and Air-Conditioning) Control Assignment:

320. Appendix 2 A2-14 A/D #5 = 4096 +200.0 °C Range of Sensor: ADC#1 = 0 0 °C ADC#1 = 4096 +300.0 °C [ dCusf ] Fn _ #5 Def _ PID S = ADC(5) * (200-50)/4096 + 50 ‘Convert to o C T = ADC(1) * (300 - 0)/4096 X = PIDcompute(1, S - T)/100 + 2048 ‘X can vary + 50% setDAC 1, X ‘ Write to analog D/A output #1 Custom Function #6 P = 500: I = 50: D = 0 PIDDEF 1, 2048 * 100 ,P,I,D ‘ Use PID Engine #1, max limit ‘ = +/- 50% of full scale Custom Function #5 [ dCusf ] Fn _ #6 Clk1.0s Comments: 1) We use two decimal places to represent the gains K P , K I and K D . Each integer unit represents 0.01. Proporti onal gain KP = 5 is represented by variable P = 500. Likewise, Integral ga ins KI = 0.5 is represented by I = 50 and Differential gains = 0 means Differ ential term is not used (P.I. only). The integrator limits of + 2048 for the PIDDEF statement must be multiplied by 100 to be put on the same scale as the P,I and D parameters. Note that since TRiLOGI does not su pport floating point arithmetic, the multiplication must be carri ed out before the division . Otherwise, if you compute 150/4096 *ADC(5), the result of the integer division of 150/4096 = 0 and the whole expression yields a ‘0’, which is clearly wrong! 2) The value returned by PIDcompute() function is then divided by 100 to get the real value of controller output. PI Dcompute() returns a signed value

313. Appendix 2 A2-7 Increase Tim1 Out1 [ δ Cusf] Fn_#101 Fn_#102 Decrease Out1 Test setTimerSV 1,getTimerSV(1)-5 ‘Decrease SV by 5 SETLCD 1,1,”T1-SV=”+STR$(getTimerSV(1),4) Custom Function #102 Z = getTimerSV(1) IF Z > 100 RETURN: ENDIF ‘ MAXIMUM 10s setTimerSV 1, Z+5 ‘Increase the current SV by 5 (0.5s) SETLCD 1,1,”T1-SV=”+STR$(getTimerSV(1),4) Custom Function #101 [dCusf] [dCusf] (OUT) Tim1 (TIM) Comments: The getTimerSV(1) function returns the current se t value of the Timer #1. This value is read into variable Z in CusFn #101 but used directly in CusFn #102 for changing the Set Value of Timer #1. The setTimerSV statement uses the value of its second argument to update Timer #1’s SV accordingly. Note that changes to the set value SV will be updated in the program EEPROM memory and is non-volatile. However, EE PROM has a typical life-span of about 100,000 to 1,000,000 erase-write cycle. Ex ceeding this limit will “wear out” the EEPROM and resulting in a read error wh en the PLC operates. Hence, you should NEVER write a program that excessively changes the set value of the timer or counter (e.g. put it in a non-differentiate d form of [CusFn] which executes every scan of the ladder program and continuously changes the content of the EEPROM). A2.2.3 Using a Potentiometer As An Analog Timer

316. Appendix 2 A2-10 Fn_#10 DEFHOME DM[1] = 1500: DM[2]= -2000: DM[3]=4500 ‘Store index position DM[4]=9000: DM[5]=0 N = 1 STEPSPEED 1, 5000,100 ‘Stepper1: Max 5000pps, Acc:100 STEPMOVEABS 1, DM[N], 5 ‘ Move to position stored in DM[1] ‘ at the end, turns ON relay 5 STEPHOME(1) ‘Define the HOME position for stepper 1 Custom Function #10 Fn_#11 START Custom Function #11 [dCusf ] [ dCusf ] N = N+1 IF N <= 5 STEPMOVEABS 1, DM[N], 5 ‘Move to next position in DM[N] ENDIF ‘ at the end, turns ON relay 5 Custom Function #11 Custom Function #20 T1sec RLY5 ( TIM ) Fn_#20 T1sec [dCusf ] Comments: RLY5 is the label for internal relay #5. T1se c is a timer with pres et value of 10. At the end of the pulse generation, RLY5 wi ll be activated. Ladder logic senses RLY5 and executes the T1sec timer to cause a 1 second delay, after which custom function #20 is executed which triggers another STEPMOVEABS command and the process repeats for the other four indexing positions. A2.2.5 Activate Events at Scheduled Date and Time All ‘Super’ PLCs have built-in Real Ti me Clock which keeps track of Date and Time and can be used to activate events at scheduled time. Assignment: 1. Every day turn on output #1 (label name: Out1) at 19:00. 2. Turn OFF output #1 at 7:00

9. USER MANUAL Page ix 12.9   CRC16 (var, count).................................................................................... 12-4   12.10   DELAY n .................................................................................................. 12-5   12.11   EXIT.............................................................................................................. 12-5   12.12   FOR ... NEXT ................................................................................................ 12-6   12.13   GET_IPAddr dmindex.............................................................................. 12-7   12.14   GET_DNS dmindex .................................................................................. 12-8   12.15   GET_GATEWAY dmindex ........................................................................ 12-8   12.16   GET_SMTP dmindex................................................................................. 12-9   12.17   GET_SUBNET dmindex ........................................................................... 12-10   12.18   GetCtrSV (n) Ge tTimerSV (n) .................................................................. 12-10   12.19   GETHIGH16(v) .......................................................................................... 12-11   12.20   HEX$(n) HEX$ (n, d)................................................................................. 12-11   12.21   HSCDEF ch, fn_num, value ..................................................................... 12-12   12.22   HSCOFF ch ............................................................................................... 12-13   12.23   HSTIMER n ................................................................................................. 12-13   12.24   I2C_READ i2cslave , dmstart, count..................................................... 12-14   12.25   I2C_STOP .................................................................................................. 12-15   12.26   I2C_WRITE i2cslave , dmstart, count .................................................... 12-15   12.27   IF .. THEN .. ELSEIF .. ELSE .. ENDIF ............................................................ 12-17   12.28   INCOMM(ch) ........................................................................................... 12-19   12.29   INPUT$(ch)................................................................................................ 12-19   12.30   INTRDEF ch, fn _num, edge...................................................................... 12-20   12.31   INTROFF ch ............................................................................................... 12-20   12.32   LEN (x$)..................................................................................................... 12-20   12.33   LET.............................................................................................................. 12-21   12.34   LOAD_EEP(addr) LOAD_EEP8 (addr8) LOAD_EEP16 (addr16) LOAD_EEP32 (addr32) 12-21   12.35   LOAD_EEP$ (addr) ................................................................................... 12-23   12.36   LSHIFT i, n .................................................................................................. 12-23   12.37   MID$(x$, n, m) ......................................................................................... 12-24   12.38   NETCMD$ (ch, x$).................................................................................... 12-24   12.39   OUTCOMM n, x...................................................................................... 12-25   12.40   PAUSE........................................................................................................ 12-26   12.41   PIDcompute(ch, E) .................................................................................. 12-26   12.42   PIDdef ch, lmt, P, I, D, .............................................................................. 12-28   12.43   PMON ch PMOFF ch ............................................................................. 12-29   12.44   PRINT# n x$; y; z.... Statement ........................................................... 12-29   12.45   PULSEFREQUENCY(ch) PULSEPERIOD(ch) PULSEWIDTH(ch) .................. 12-30  

4. USER MANUAL Page iv TABLE OF CONTENTS Page # 1   I-TRILOGI 6 SETUP GUIDE 1-1   1.1   Introduction to the i-TRiLOGI Program ...................................................... 1-1   1.2   Download the Latest Ve rsion of I-TRiLOGI ................................................ 1-1   1.3   Install Java Run Time En viroment JRE 1.4.2_19......................................... 1-1   1.4   Install i-TR iLOGI 6.x ...................................................................................... 1-2   1.5   Run TRiLOGI and TLServer ........................................................................... 1-8   1.6   Using TRiLOGI 6.x with International Languages ...................................... 1-9   2   INTRODUCTION TO I-TR ILOGI CLIENT/SERVER 2-1   2.1   Client/Server Architecture.......................................................................... 2-1   2.1.1   Client ......................................................................................................................... .... 2-1   2.1.2   Server......................................................................................................................... .... 2-1   2.2   i-TRiLOGI Client So ftware Versions............................................................. 2-2   2.2.1   Java Appl icatio n ......................................................................................................... 2-2   2.2.2   Java Ap plet.................................................................................................................. 2-2   2.3   i-TRiLOGI Application vs Applet: Which is Better? ................................... 2-3   3   INTERFACING TO THE PLC 3-1   3.1   Physical Connection ................................................................................... 3-1   3.1.1   Serial Port .................................................................................................................... .. 3-2   3.1.2   Ethernet....................................................................................................................... .. 3-3   3.2   Software Interface ....................................................................................... 3-5   3.2.1   TLServer Setup .............................................................................................................. 3-5   3.2.2   TRiLOGI Comm unication ............................................................................................ 3-7   4   USING THE TLSERVER – WEB SERVER FOR TRILOGI 4-1   4.1   Overview ...................................................................................................... 4-1   4.2   Serial Port Setup ........................................................... 4-4   4.2.1   Setting Up and Testing TLServer's Serial Communication Port .............................. 4-4   4.2.2   Changing Communication Settings......................................................................... 4-5   4.2.3   Modem Su pport........................................................................................................... 4-6   4.3   Configure Users ............................................................ 4-9   4.3.1   Select Us ername.......................................................................................................... 4-9   4.3.2   Add New User ............................................................................................................ 4-10   4.3.3   Server Port................................................................................................................... 4-10   4.3.4   What Port Number Sh ould TLServer Use?............................................................... 4-10   4.4   Setup Emails .......................................................... 4-11   4.4.1   Introduction ................................................................................................................ 4-11   4.4.2   Configure And Test SMTP EMail Server ................................................................... 4-13   4.4.3   Setting Up TLServer As Email Mast er For Multiple PLCs on RS485........................ 4-17  

10. USER MANUAL Page x 12.46   READMODBUS (ch, ID, addr) .................................................................. 12-31   12.47   READMB2 ch, ID, addr, var, count..................................................... 12-32   12.48   REFRESH..................................................................................................... 12-33   12.49   REM (or ') Statement........................................................................... 12-34   12.50   RESET ......................................................................................................... 12-34   12.51   RESTART REBOOT.................................................................................... 12-34   12.52   RETURN ...................................................................................................... 12-35   12.53   RSHIFT i,n Statement.............................................................................. 12-35   12.54   SAVE_EEP data, addr SAVE_EEP8 dat a, addr8 SAVE_EEP16 data, addr16 SAVE_EEP32 data, addr32 .............................................................................................. 12-36   12.55   SAVE_EEP$ st rdata, addr ...................................................................... 12-38   12.56   SET_DNS dmindex ................................................................................. 12-39   12.57   SET_GATEWAY dmindex.......................................................................... 12-40   12.58   SET_IPAddr dmindex............................................................................. 12-41   12.59   SET_SMTP dm index .................................................................................. 12-42   12.60   SET_SUBNET dmindex............................................................................... 12-42   12.61   SETBAUD ch , baud_no............................................................................. 12-43   12.62   SETBIT v,n .................................................................................................. 12-44   12.63   SetCtrSV n, value ..................................................................................... 12-45   12.64   SETDAC n, x Statement ......................................................................... 12-45   12.65   SETDimmer ch, value ............................................................................ 12-46   12.66   SETHIGH16 v, data ................................................................................... 12-47   12.67   SETIO labelname................................................................................... 12-47   12.68   SETLCD n, o ffset, x$ .................................................................................. 12-47   12.69   SETPASSWORD string ............................................................................. 12-48   12.70   SETPROTOCOL ch, mode...................................................................... 12-49   12.71   SETPWM n, x, y.......................................................................................... 12-51   12.72   SETSYSTEM n, data................................................................................. 12-51   12.72.1   Com Response Wait Time ...................................................................................... 12-52   12.72.2   Number of Com Retries .......................................................................................... 12-53   12.72.3   Hostlink Command Response Time ...................................................................... 12-54   12.72.4   Configure Quadra ture Encoding.......................................................................... 12-54   12.72.5   DM[]s Cleared Du ring Reset .................................................................................. 12-55   12.72.6   Modbus Functi on Select......................................................................................... 12-55   12.72.7   Change ID ................................................................................................................ 12-55   12.72.8   Fast Refresh............................................................................................................... 12-56   12.72.9   Calibrate RTC ........................................................................................................... 12-57   12.72.10   Number of I/O to Support ...................................................................................... 12-57   12.72.11   Enable IR Remote .................................................................................................... 12-57   12.72.12   Pulse Measurement Resolution.............................................................................. 12-58   12.72.13   Dimmer Interrupt Enable ........................................................................................ 12-58   12.72.14   Quadrature Encoder Config ................................................................................. 12-58  

11. USER MANUAL Page xi 12.72.15   Analog Outp ut Range............................................................................................ 12-58   12.72.16   Close TCP Connection ........................................................................................... 12-59   12.72.17   Write to Flash ............................................................................................................ 12-59   12.72.18   Control the RTC operation. .................................................................................... 12-59   12.72.19   Ethernet Port Enable ............................................................................................... 12-60   12.72.20   Watchdog Timer ...................................................................................................... 12-60   12.72.21   I/O Scan Interrupt .................................................................................................... 12-61   12.73   SetTimerSV n, value................................................................................. 12-62   12.74   SLEEP ......................................................................................................... 12-62   12.75   STATUS (n) ................................................................................................. 12-63   12.76   STEPCOUNT (ch)....................................................................................... 12-67   12.77   STEPCOUNTABS (ch) ................................................................................ 12-68   12.78   STEPHOME ch ....................................................................................... 12-68   12.79   STEPMOVE ch, count, r ............................................................................ 12-68   12.80   STEPMOVEABS ch , position, r ............................................................... 12-70   12.81   STEPSPEED ch, pps, acc .......................................................................... 12-71   12.82   STEPSTOP ch ............................................................................................. 12-71   12.83   STR$(n) STR$ (n, d) ................................................................................... 12-72   12.84   STRCMP(A$, B$)........................................................................................ 12-72   12.85   STRLWR$(A$)............................................................................................. 12-72   12.86   STRUPR$(A$) ............................................................................................. 12-73   12.87   TESTBIT (v, n) ............................................................................................. 12-73   12.88   TESTIO (labelname) ................................................................................. 12-74   12.89   TOGGLEIO l abelname .......................................................................... 12-74   12.90   VAL(x$) ..................................................................................................... 12-74   12.91   WHILE expression .... ENDWHILE.............................................................. 12-74   12.92   WRITEMODBUS ch, Device ID, address, data......................................... 12-75   12.93   WRITEMB2 ch, ID , addr, var, count .................................................... 12-76   A-1   QUICK START: PLC TO PC COMMUNICATION GUIDE 1-1   A1.1   Part 1: Serial Commun ication Set up Guide.............................................. 1-1   A1.2   Part 2: Ethernet Comm unication Set up Guide ......................................... 1-9   A-2   APPENDIX 2 : APPLICATION NOTES & PROGRAMMING EXAMPLES 2-1   A2.1   Important Notes to Programmer s of TRiLOGI Version 6.x ........................ 2-1   A2.1.1   Understanding Ladder Logi c Execution Process .................................................... 2-1   A2.1.2   The Difference Between {CusFn} and {dCusF} ....................................................... 2-2   A2.1.3   Timers Contact Updating Process............................................................................. 2-3   A2.2   TRiLOGI Sample programs.......................................................................... 2-4   A2.2.1   Display Alphanumeric Messages on built-in LCD Display ..................................... 2-5   A2.2.2   Setting Timer/Counter Set Values (S.V.) Using LCD Display .................................. 2-6   A2.2.3   Using a Potentiometer As An Analog Timer ............................................................ 2-7   A2.2.4   Motion Control of Stepper Motor.............................................................................. 2-9  

5. USER MANUAL Page v 4.4.4   Writing i-TRiLOGI Programs that Can Send Emails via TLServer as Email Master 4-18   4.5   File and Ema il Services ............................................................................. 4-19   5   RUNNING THE INTERNET TRILOGI CLIENT 5-1   5.1   Starting The i-TRiL OGI Application ............................................................. 5-1   5.2   Running TRiLOGI Applet Using Web Browser ............................................ 5-2   6   LADDER LOGIC PROG RAMMING TUTORIAL 6-1   6.1   Ladder Logic Programmi ng Tutorial : STEP1............................................... 6-2   6.2   Ladder Logic Programmi ng Tutorial: STEP 2.............................................. 6-4   6.3   Ladder Logic Programmi ng Tutorial: STEP 3.............................................. 6-5   6.4   Ladder Logic Programmi ng Tutorial: STEP 4.............................................. 6-9   6.5   Ladder Logic Programmi ng Tutorial: STEP 5............................................ 6-12   6.6   Ladder Logic Programmi ng Tutorial: STEP 6............................................ 6-16   7   I-TRILOGI LADDER LOGIC EDITOR 7-1   7.1   The Browse Mode ........................................................................................ 7-1   7.1.1   Mouse Actions.............................................................................................................. 7-1   7.1.2   Keyboard Actions........................................................................................................ 7-1   7.1.3   Navigating Circuits in Brow se Mo de ........................................................................ 7-2   7.2   The Circu it Menu ......................................................................................... 7-4   7.2.1   Insert Co mments.......................................................................................................... 7-4   7.2.2   Insert Circuit ................................................................................................................. . 7-5   7.2.3   Move Circuit ................................................................................................................. 7-5   7.2.4   Append Circuit ............................................................................................................ 7-5   7.2.5   Delete Ci rcuit ............................................................................................................... 7-5   7.3   The Edit Menu............................................................................................... 7-6   7.3.1   Cut Circuit.................................................................................................................... . 7-6   7.3.2   Copy Circuit (Ctrl-C) ................................................................................................... 7-6   7.3.3   Paste Circuit (Ctrl-V).................................................................................................... 7-7   7.3.4   Find (Ctrl-F) .................................................................................................................. . 7-7   7.3.5   Goto (Ctrl-G) ................................................................................................................ 7-7   7.4   The Circuit Editing Mode............................................................................. 7-7   7.4.1   Mouse Actions.............................................................................................................. 7-8   7.4.2   Create Ladder Circuit Using The Keyboard ............................................................ 7-9   8   TRILOGI MAIN MENU REFERENCE 8-1   8.1   File Menu ...................................................................................................... 8-1   8.1.1   New <Ctrl+N>......................................................................................................... 8-2   8.1.2   Save <Ctrl+S>........................................................................................................... 8-2   8.1.3   Open (TLServer 3) - <Ctrl+O> ..................................................................................... 8-2   8.1.4   Save As (TLServer 3)..................................................................................................... 8-3   8.1.5   Open (Local Drive) / Sa ve As (Local Drive) ............................................................ 8-4   8.1.6   View Protect / Un-Protect .......................................................................................... 8-5   8.1.7   Write Compiled Code to Disk .................................................................................... 8-6   8.1.8   Print .......................................................................................................................... ...... 8-6   8.1.9   Exit ........................................................................................................................... ....... 8-9  

8. USER MANUAL Page viii 10.5   Simulation & Examination of TBASIC Variables .................................... 10-18   10.5.1   Simulation Run of CusFn. ........................................................................................ 10-19   10.5.2   Viewing TBASIC Variables....................................................................................... 10-20   10.5.3   Changing the Contents of Variables ................................................................... 10-22   10.5.4   Decimal and Hexadeci mal Representation ....................................................... 10-22   10.6   On-line Monitoring of TBASIC Variables................................................ 10-23   10.6.1   PAUSE and RESET of Target PLC............................................................................. 10-23   10.6.2   Using LCD Displa y for Debugging ......................................................................... 10-23   10.7   Debugging With PAUS E & Breakpoints .................................................. 10-23   10.7.1   Using the TBASIC PAUSE Statement ...................................................................... 10-23   10.7.2   Using Breakpoints..................................................................................................... 10-24   10.7.3   Debugging Using Breakp oint on Simulator.......................................................... 10-26   10.7.4   Debugging Using Breakpoints on PLC.................................................................. 10-26   10.8   Error Handling .......................................................................................... 10-27   10.8.1   Syntax Error ............................................................................................................... 10-27   10.8.2   Run-Time Errors ......................................................................................................... 10-29   11   TBASIC STATEMENTS, FUNCTIONS, OPERATORS AND VARIABLES 11-1   11.1   What are TBASIC Stat ement and F unctions? .......................................... 11-1   11.1.1   STATEMENT .................................................................................................................. 11-1   11.1.2   FUNCTION ................................................................................................................... 11-1   11.1.3   DELIMITER .................................................................................................................... 11-1   11.2   TBASIC Integer Constants, Variables & Operators ................................. 11-2   11.2.1   Integer Constants ...................................................................................................... 11-2   11.2.2   Integer variables:....................................................................................................... 11-3   11.2.3   System va riables: ....................................................................................................... 11-4   11.2.4   Integer operators:...................................................................................................... 11-6   11.2.5   Hierarchy of Operators ............................................................................................. 11-7   11.2.6   Integer Variable Comments .................................................................................... 11-8   11.2.7   Variable Define Table (NEW!) .................................................................................. 11-8   11.3   String Constants, Vari ables & Operators............................................... 11-10   11.3.1   String Constants ....................................................................................................... 11-10   11.3.2   String Variables ........................................................................................................ 11-10   11.3.3   String Operators ....................................................................................................... 11-11   11.3.4   String Variable Comments ..................................................................................... 11-11   11.3.5   Variable Define Table (NEW!) ................................................................................ 11-12   12   TBASIC KEYWORD REFERENCE 12-1   12.1   ABS(x) ......................................................................................................... 12-1   12.2   ADC(n)........................................................................................................ 12-1   12.3   ASC(x$, n) .................................................................................................. 12-1   12.4   CALL n......................................................................................................... 12-2   12.5   CHR$(n) ...................................................................................................... 12-2   12.6   CLRBIT v, n .................................................................................................. 12-2   12.7   CLRIO labelname SETIO labelname TOGGLEIO labelname TESTIO (labelname) ........................................................................................................ 12-3   12.8   CONTINUE................................................................................................... 12-4  

7. USER MANUAL Page vii 9.2.1   Clock pulse bits ............................................................................................................ 9-6   9.2.2   SeqN:X ......................................................................................................................... .. 9-7   9.2.3   Normally ON Flag - Norm.ON .................................................................................... 9-7   9.2.4   First Scan Puls e - 1st.Scan ........................................................................................... 9-7   9.2.5   Real Time Clock Error - RTC.Err ................................................................................... 9-8   9.3   Special Functions ........................................................................................ 9-8   9.3.1   Reversible Counter Functions: [DNctr], [Upctr] and [RSctr] .................................. 9-9   9.3.2   Sequencer Functions: [AVseq ], [RSseq] an d [StepN] .......................................... 9-11   9.3.3   Latch Relay Function [Latch] .................................................................................. 9-11   9.3.4   Clear Relay Func tion [Clear] ................................................................................... 9-12   9.3.5   Interlock [ILock].......................................................................................................... 9-12   9.3.6   Differentiate Up and Down [d DIFU] and [d DI FD] ............................................... 9-13   9.3.7   Custom Functions: [C usFn] and [dCusF]................................................................ 9-14   9.3.8   Master Reset............................................................................................................... 9-14   9.4   Using i-TRiLOGI Sequencers ..................................................................... 9-14   9.4.1   Special Sequence r Functions .................................................................................. 9-17   9.4.2   Other Applications .................................................................................................... 9-17   9.4.3   Program Example ...................................................................................................... 9-18   10   INTRODUCTION TO TBAS IC CUSTOM FUNCTIONS 10-1   10.1   Overview .................................................................................................... 10-1   10.2   Custom Func tion Editor............................................................................. 10-1   10.2.1   Split Pane Window..................................................................................................... 10-2   10.2.2   New Help Features. ................................................................................................... 10-3   10.2.3   Cursor Position ............................................................................................................ 10-6   10.2.4   Search / Find and Replace...................................................................................... 10-7   10.2.5   Navigating Custom Functions ................................................................................. 10-8   10.2.6   View Other Custom Functions ................................................................................. 10-9   10.2.7   Undo Changes .............................................................................. 10-10   10.2.8   Aborting Changes .................................................................... 10-10   10.2.9   #Define Table .................................................. 10-11   10.2.10   Toggle Breakpoint ........................................... 10-11   10.3   Define Table ............................................................................................. 10-11   10.3.1   Find ........................................................................................................................... . 10-12   10.3.2   Insert Row.................................................................................................................. 10-12   10.3.3   Delete Row ............................................................................................................... 10-12   10.3.4   Copy Row ................................................................................................................. 10-13   10.3.5   Paste Row ................................................................................................................. 10-13   10.3.6   Import #Define Table .............................................................................................. 10-13   10.3.7   Export #Define Table .............................................................................................. 10-14   10.3.8   More Information on #Define Tables ................................................................... 10-14   10.4   How to Use A Custom Function.............................................................. 10-14   10.4.1   Triggered by Ladder Logic Specia l function coil [CusFn] ............................ 10-14   10.4.2   Periodic Execution of a Custom Function ........................................................... 10-16   10.4.3   Interrupt Service CusFn ........................................................................................... 10-17  

6. USER MANUAL Page vi 8.2   Edit Menu ..................................................................................................... 8-9   8.2.1   Abort Edit Circuit.......................................................................................................... 8-9   8.2.2   Undo <Ctrl+Z> ........................................................................................................ 8-10   8.2.3   Cut Circuit - <Ctrl+X> ................................................................................................ 8-10   8.2.4   Copy Circuit (Ctrl+C) ................................................................................................ 8-10   8.2.5   Paste Circuit <Ctrl+V> ............................................................................................... 8-10   8.2.6   Find <Ctrl+F> .......................................................................................................... 8-11   8.2.7   Goto <Ctrl+G>....................................................................................................... 8-12   8.2.8   I/O Table <F2> ......................................................................................................... 8-12   8.2.9   View I/O Type on Ladder <F3> ............................................................................. 8-12   8.2.10   Edit Custom Function <F7> .................................................................................... 8-13   8.2.11   Clear Custom Functions ........................................................................................... 8-13   8.2.12   Set TAB Width ............................................................................................................. 8-14   8.3   Controlle r Menu......................................................................................... 8-14   8.3.1   Select Controller <Ctrl-I> ...................................................................................... 8-14   8.3.2   Connect/Disconnect to Server ............................................................................... 8-15   8.3.3   On-Line Monitori ng <Ctrl+M>................................................................................ 8-15   8.3.4   Program Transfer to PLC <Ctrl+T> ......................................................................... 8-15   8.3.5   Transfer .CO5 File To PLC .......................................................................................... 8-16   8.3.6   Open Matching Source File..................................................................................... 8-16   8.3.7   Get PLC's Hardware Info .......................................................................................... 8-16   8.3.8   Set PLC's Real Time Clock ........................................................................................ 8-17   8.3.9   EEPROM Manager ..................................................................................................... 8-17   8.3.10   Ethernet & ADC Configur ation................................................................................ 8-21   8.3.10.1   BASIC CONFIGURATION............................................................................................ 8-24   8.3.10.2   ADVANCED CONFIGURATION................................................................................. 8-30   8.3.11   Auto Analog Calibration .......................................................................................... 8-36   8.4   Simulate Menu........................................................................................... 8-41   8.4.1   Run (All I/O Reset) <Ctrl+F9> ............................................................................... 8-41   8.4.2   Run (reset Except i/p) <Ctrl+F8> ........................................................................... 8-41   8.4.3   Continue Run (no reset) <F9> ............................................................................... 8-42   8.4.4   Compile Only <F8> ............................................................................................... 8-42   8.4.5   Reset All I/Os <Ctrl-R> ............................................................................................... 8-42   8.5   Circuit Menu .............................................................................................. 8-43   8.5.1   Insert Co mments........................................................................................................ 8-43   8.5.2   Insert Circuits .............................................................................................................. 8-43   8.5.3   Move Circuit ............................................................................................................... 8-43   8.5.4   Append Circuit .......................................................................................................... 8-44   8.5.5   Delete Ci rcuit ............................................................................................................. 8-44   8.6   Help Menu.................................................................................................. 8-44   9   LADDER LOGIC LANGUAGE REFERENCE 9-1   9.1   Ladder Logic Fundamentals: Contacts, Coils, Timers and Counters ..... 9-1   9.1.1   Contacts ....................................................................................................................... 9-1   9.1.2   Relay Coils .................................................................................................................... 9-4   9.1.3   Out Coils...................................................................................................................... .. 9-5   9.1.4   Timer Coils .................................................................................................................... . 9-5   9.1.5   Counter Coils................................................................................................................ 9-5   9.2   Special Bits ................................................................................................... 9-6  